Emerson Process Management / Process Liquid Division / Uniloc Division
Irvine, CA 92606
Share:
New Electrolyte Refill Kits for Emerson's PERpH-X pH Sensor Family Expand Application Flexibility
IRVINE, Calif., July 31, 2007 - Emerson Process Management today announced new reference electrolyte refill kits that expand application flexibility of the Rosemount Analytical PERpH-X(TM) sensor family for a broad range of applications. The PERpH-X sensor family is customized for different processes by using different reference electrolytes. Six different refill solution kits are available: the...
Read More »Liquid Analysis Platform allows single or dual inputs.
Suited for OEM and liquid analysis applications, Model 1056 Single/Dual Input analyzer allows users to choose from combination of measurements such as pH/ORP/ISE, resistivity/conductivity, chlorine, oxygen, and temperature. Backlit LCD can display 4 process variables or diagnostic parameters simultaneously. Designed with modular cards and removable connectors to aid reconfiguration in field,...
Read More »pH Sensors perform in temperatures to 293-
Models 3300HT and 3400HT pH sensors handle pressures of 100 psig at 145Ã-
Read More »Sensor suits CIP analysis in pharmaceutical industry.
Rosemount Analytical Model 225-08 toroidal conductivity sensor comprises of pair of wire-wound metal toroids overmolded with special grade of PEEK. It can be integrated into DeltaV digital automation system that powers PlantWebÃ-® digital plant architecture. Sensor offers conductivity range from 200 Ã-µS/cm to 2 S/cm and incorporates integral temperature sensor for temperature...
Read More »Analysis System provides continuous chlorine measurement.
Comprised of sample conditioning system, analyzer, and sensor, Model TCL measures total chlorine in water, including seawater. It requires only distilled white vinegar and potassium iodide as reagents, which only need to be replaced every 2 months. System uses either Model 1055 Solu Comp II analyzer or Model 54eA analyzer, both of which are housed in NEMA 4X enclosures and provide programmable...
Read More »Chemically Durable pH Sensor withstands harsh processes.
Model 398 TUpHÃ-® pH/ORP Sensor employs PEEK plastic helical reference pathway that protects reference element from chemical attack. Resistant to oxidants and organic solvents, sensor integrates AccuGlass pH electrode to resist cracking and SILCORE triple-seal contaminant barrier to protect integrity of pH measurement. Product is constructed of chemical-resistant titanium and TefzelÃ-®...
Read More »CIP Pharmaceutical Sensor incorporates PEEK material.
Model 225-08 toroidal conductivity sensor consists of pair of wire-wound metal toroids overmolded with U.S.P. Class VI PEEK material. Suited for use in concentrations of acids, alkalis, and rinse waters, product incorporates integral temperature sensor for temperature compensation and has conductivity range from 200 Ã-µS/cm to 2 S/cm. Sensor meets requirements of clean-in-place (CIP) liquid...
Read More »Dissolved Oxygen Sensor suits carbonated beverage process.
Able to withstand caustic clean-in-place cycles, Model Bx438 monitors trace levels of dissolved oxygen in beer and other carbonated beverages. Steel-meshed, double-layer membrane enables sensor to withstand high pressure and temperature while maintaining high diffusion rates. Zero polarization set point ensures accuracy. Changes in flow rates have minimal impact on measurements, so sensor...
Read More »On-LineTurbidimeter offers single or dual channels.
Clarity II(TM) enables drinking water plants to continuously monitor turbidity levels on-line to ensure protection of water quality, while meeting stringent EPA requirements, as well as international ISO standards. It incorporates Solu Comp II analyzer, sensor, and sampling chamber. No additional sensor wiring is required.
Read More »Transmitter can be set up from remote location.
Model 5081 two-wire transmitter, using HART and FOUNDATION Fieldbus digital communications protocols, provides access to Asset Management Solutions and other host applications. User can read process variables and troubleshoot problems from PC. Transmitter can be configured for pH, conductivity, or amperometric measurement. Amperometric transmitter Model 5081A measures dissolved oxygen, free...
Read More »New Electrolyte Refill Kits for Emerson's PERpH-X pH Sensor Family Expand Application Flexibility
IRVINE, Calif., July 31, 2007 - Emerson Process Management today announced new reference electrolyte refill kits that expand application flexibility of the Rosemount Analytical PERpH-X(TM) sensor family for a broad range of applications. The PERpH-X sensor family is customized for different processes by using different reference electrolytes. Six different refill solution kits are available: the...
Read More »Liquid Analysis Platform allows single or dual inputs.
Suited for OEM and liquid analysis applications, Model 1056 Single/Dual Input analyzer allows users to choose from combination of measurements such as pH/ORP/ISE, resistivity/conductivity, chlorine, oxygen, and temperature. Backlit LCD can display 4 process variables or diagnostic parameters simultaneously. Designed with modular cards and removable connectors to aid reconfiguration in field,...
Read More »pH Sensors perform in temperatures to 293-
Models 3300HT and 3400HT pH sensors handle pressures of 100 psig at 145Ã-
Read More »Emerson Awarded Contract for Digital Automation of First Phase Of $9.4 Billion Horizon Oil Sands Project In Canada
Emerson's integration and automation services and PlantWebÃ-® digital architecture key to selection by Canadian Natural Resources AUSTIN, TEXAS (June 14, 2006) - Emerson Process Management, a business of Emerson (NYSE:EMR), announced today that it has been awarded a contract by Canadian Natural Resources Ltd. (CNRL) to digitally automate the first phase of its USD$9.4 billion Horizon Oil...
Read More »Emerson's Water Quality Monitoring System has Performance Verified by the Epa Environmental Technology Verification Program
Rosemount Analytical Model WQS performed unattended, with no maintenance required during the entire evaluation IRVINE, CALIF. (March 23, 2006) - Emerson Process Management today announced that the performance of the Rosemount Analytical Model WQS water quality monitoring system has been verified by the U.S. Environmental Protection Agency (EPA) Environmental Technology Verification program. The...
Read More »Sensor suits CIP analysis in pharmaceutical industry.
Rosemount Analytical Model 225-08 toroidal conductivity sensor comprises of pair of wire-wound metal toroids overmolded with special grade of PEEK. It can be integrated into DeltaV digital automation system that powers PlantWebÃ-® digital plant architecture. Sensor offers conductivity range from 200 Ã-µS/cm to 2 S/cm and incorporates integral temperature sensor for temperature...
Read More »Liquid Analytical Instrumentation Solutions from Emerson Process Management Improve Process Reliability, Efficiency and Profitability
Come See Emerson Process Management at Worldwide Food Expo 2005 at Booth #N2714 IRVINE, Calif., Oct. 26 /PRNewswire/ -- For today's food and beverage producers, tight margins are a fact of life. Proper liquid analysis throughout the process keeps production running reliably and efficiently, and can mean the difference between profit and loss. Emerson Process Management today announced it will...
Read More »Emerson Highlights New Total Chlorine Analysis System and Industry's Most Complete Line of Water And Wastewater Analytical Solutions At WEFTEC 2005
IRVINE, Calif., October 31, 2005 - At WEFTEC 2005, Emerson Process Management will demonstrate its new Model TCL total chlorine analysis system and its complete line of Rosemount Analytical analyzers, transmitters and sensors designed for liquid analysis in water and wastewater applications. Emerson will exhibit at booth number 5510 of WEFTEC, which is being held at the Washington Convention...
Read More »Analysis System provides continuous chlorine measurement.
Comprised of sample conditioning system, analyzer, and sensor, Model TCL measures total chlorine in water, including seawater. It requires only distilled white vinegar and potassium iodide as reagents, which only need to be replaced every 2 months. System uses either Model 1055 Solu Comp II analyzer or Model 54eA analyzer, both of which are housed in NEMA 4X enclosures and provide programmable...
Read More »Chemically Durable pH Sensor withstands harsh processes.
Model 398 TUpHÃ-® pH/ORP Sensor employs PEEK plastic helical reference pathway that protects reference element from chemical attack. Resistant to oxidants and organic solvents, sensor integrates AccuGlass pH electrode to resist cracking and SILCORE triple-seal contaminant barrier to protect integrity of pH measurement. Product is constructed of chemical-resistant titanium and TefzelÃ-®...
Read More »