Acromag, Inc.

I/O Modules provide 2 CAN bus isolated interfaces.
Controls & Controllers

I/O Modules provide 2 CAN bus isolated interfaces.

Supporting CAN 2.0B protocol, Model IP560 consists of Industry Pack ANSI/VITA-4 card that plugs into VME, CompactPCI, and PCI bus mezzanine carrier cards or single-board computers in embedded systems. Model IOS-560 operates within I/O Server industrial PC, which services mobile computing, machine control, and test applications. Both modules include 2 channels, each featuring NXP SJA1000 CAN...

Read More »
Networking Cable brings Ethernet to analog signal conditioners.
Communication Systems & Equipment

Networking Cable brings Ethernet to analog signal conditioners.

Providing DB25 male to 26-pin female IDC ribbon cable connection, Model 4001-110 interfaces rack of up to 16 3B or 5B modules, providing conditioned voltage signals from analog sensors to Ethernet I/O modules. Converting signal conditioners' outputs to digital data, Ethernet I/O modules can provide Modbus TCP/IP communication to PCs, PLCs, and other distributed control devices. Typical...

Read More »
Computer Hardware & Peripherals

Fanless Industrial PC employs 500 MHz AMD Geode CPU.

Designed to process input/output signals in mobile or embedded monitoring and control applications, IOS-7200 I/O Server Industrial PC is equipped with 512 MB DDR400 DRAM, VGA graphics, 2 Ethernet ports, 2 serial ports, 4 USB ports, and CF® slot. Field I/O signals are interfaced through internal carrier card with related plug-in I/O modules. Operating from -40 to 75°C without open vents or fans,...

Read More »
OPC Server Software allows Ethernet I/O connectivity.
Software

OPC Server Software allows Ethernet I/O connectivity.

Modbus/TCP Master OPC DA Server offers high-speed connectivity to Acromag Modbus TCP/IP I/O devices via Ethernet. It can be used as data server to any HMI or SCADA package that is OPC-compliant or to custom-built Visual Basic/C++ applications. Read/write tag optimization algorithms enable high data transfer speeds between OPC server and devices. Context-sensitive help systems, Visual Basic OPC...

Read More »
ActiveX/.NET Software easesVisual Basic and Visual C++ communication interface.
Software

ActiveX/.NET Software easesVisual Basic and Visual C++ communication interface.

Aiding development of measurement/control systems, AMRN/AMRX, for Modbus/RTU, and AMTN/AMTX, for Modbus/TCP, enable interface with Modbus slave device connected to PC's serial or network ports. They include timer for polled DAQ and floating point conversion control. Software tools AMRN/AMTN are .NET controls that communicate with devices linked to PC's serial/Ethernet port. Programs allow device...

Read More »
Compact Power Supplies deliver 10-240 W of power.

Compact Power Supplies deliver 10-240 W of power.

With output voltage adjustable at ±10%, PS5R-S Slim Line series includes 9 models that provide 10 W at 5 V, 15 W at 12 or 24 V, 30 W at 12 or 24 V, and 60, 90, 120 and 240 W at 24 V. Space-saving 10 and 15 W units require 22.5 mm on DIN rail, while 240 W units are only 80 mm wide. Products have input range between 85-264 Vac, and 100-350 Vdc. They are SELV (Safety Extra Low Voltage) compliant,...

Read More »
Analog Module connects sensor data to Ethernet.
Controls & Controllers

Analog Module connects sensor data to Ethernet.

Able to simplify data acquisition from mix of analog isolation amplifiers, 958EN BusWorks module offers Ethernet interface and has 16 analog voltage inputs to accept ±5 and ±10 V signals from 8B or legacy 7B signal conditioning modules through DB25 port. Fast scanning updates all 16 channels in 8 msec, and dual-format data registers support 16-bit integer and 32-bit floating point formats....

Read More »
Analog Output Units drive voltage/current control signals.
Controls & Controllers

Analog Output Units drive voltage/current control signals.

EtherStax® ES2171 and ES2172 each provide 16 channels of process current or voltage output control signals with 16-bit D/A resolution. Both modules accept Modbus TCP/IP, UDP/IP, or i2o® peer-to-peer network inputs, and processing rate enables updates in less than 1 mS per channel. ES2171 outputs DC current signals in 0-20 or 4-20 mA range, while ES2172 units produce ±5 or ±10 Vdc signals....

Read More »
Ethernet I/O Units feature 16-bit A/D interface.
Controls & Controllers

Ethernet I/O Units feature 16-bit A/D interface.

Designed for distributed I/O and SCADA applications, EtherStax® ES2163/ES2164 perform A/D conversion on up to 64 single-ended dc current or voltage inputs, respectively, and interface signals to Ethernet devices or controllers with Modbus TCP/IP or UDP/IP communication. Scanning updates all channels in less than 10 ms, and embedded web page provides setup menus. While ES2163 accepts dc current...

Read More »
Controls & Controllers

Analog I/O Modules provide 16-channel 16-bit A/D interface.

Model 993EN BusWorks® Ethernet I/O modules accept DC current with ±20, 0-20, or 4-20 mA input ranges, while 994EN units accept ±5 or ±10 Vdc. Available in industrial-grade or commercial versions, 1 in. wide devices feature dual-format data registers supporting 16-bit integer and 32-bit floating point formats. Surge protection and 3-way 1,500 V isolation between I/O, power, and network...

Read More »