Pilz Automation Safety L.P.

Canton, MI 48187

Safety System provides safety and control functions.
With PNOZ m2p base unit, multi-functional PNOZmulti monitors and provides diagnostics for all safety equipment on press brakes, eccentric presses, and hydraulic presses. All necessary safety and standard control functions are configured on PC using PNOZmulti Configurator program. Users can configure monitoring of operating modes as well as monitoring of safety light curtains in single-break or...
Read More »
Operator Terminals come in 5 sizes.
Offered in 5 sizes from 5.7-15.0 in., PMIvisu Terminals facilitate operating and monitoring of industrial equipment. Measuring 6.5 in., PMI v316 offers 640 x 480 pixel VGA resolution. All operator and diagnostic terminals include PMI-PRO(TM) graphics software, 400 MHz RISC processor, common interfaces, and remote access tool. Units are available as open PMIopen platform for other graphics...
Read More »
Automation Control enables expansion at any time.
PSSuniversal combines decentralized, modular I/O and control platform with safety functions for automation needs. Design consists of head modules, as well as base modules that are connected alongside and available in screw or cage clamp terminals. Electronic modules are installed on base modules, allowing system to be tailored to automation requirements. PSSuniversal enables communication via...
Read More »
E-Stop Pushbuttons offer added safety for every requirement.
Mushroom-type PITestop Pushbuttons feature safety contact block, which ensures E-STOP is triggered immediately if individual contact elements are lost or attached incorrectly. Blocks have 1 or 2 N/C contacts plus additional N/O contact. Signal contacts are also available via PSEN ix1 interface, which can connect up to 4 E-stop buttons in series. IP65-rated, turn-to-release pushbuttons are...
Read More »
Safety Light Curtains protect fingers, hands, and bodies.
Suited for use in industrial applications, PSENopt light curtains and barriers are available with directly integrated, total or partial muting as well as capability to monitor muting lamps. Select versions have integral interface for SafetyBUS p safe open bus system, providing 2-way, safe communication with many additional functions in addition to diagnostic information. E-STOP or enable function...
Read More »
Coded Safety Switch is suited for safety gate monitoring.
Coding on non-contact PSENcode guarantees protection against manipulation and meets Category 4 of EN 954-1 standards. Five directions of actuation plus 17 mm switching distance ensure maximum flexibility for installation. Definite assignment of switch and its counterpart makes it impossible to manipulate safety gate being monitored. More than 10 safety switches can be connected in single series.
Read More »
Operator Terminal provides detailed diagnostics.
Configured and operated using PMI-PRO graphics software, PMIvisu operator terminals enables detailed diagnostics to be made on PSS programmable safety systems. Ventilation-free, heat-stable product includes 5.7, 10, 12, or 15 in. diagonal display and CPU board with integrated Windows CE.NET OS. Fieldbus connection can be made via internal interface, while predefined plain-text messages and...
Read More »
Safety Sensor provides 8 mm switching distance.
Non-contact, magnetic PSEN 2.2 Safety Switch has round cylindrical design that suits position monitoring and safety gate monitoring. High lateral offset provides tolerant dimensions for installation and insensitivity towards spring-back or swinging from safety gates. Switch has BG approval EN 60 947-5-3 for applications up to Category 4 in accordance with EN 954-1. PSEN 2.2 also provides security...
Read More »
Magnetic Safety Switch provides safety gate monitoring.
Non-contact Model PSEN 1.1, used in conjunction with electromechanical evaluation devices, offers complete solution for safety gate monitoring. It features switching distance of 3 mm and provides security against manipulation due to evasion protection in accordance with VDE 0660. Dust-tight and waterproof, switch conforms to protection type IP67 and can withstand shock and vibration. Mechanically...
Read More »
Two-Hand Control Device is suited for use on presses.
PNOZ e2.1p electronic, 2-hand control device is suited for type IIIC in accordance with EN 574. Using semiconductor technology, non-wearing product requires no maintenance and is resistant to shock and vibration. Enclosed in 22.5 mm slim-line housing, it is comprised of 2-hand control, emergency stop function, and operating mode selector switch. Unit also offers continuous function test on inputs...
Read More »