Ophir Optics, LLC
North Andover, MA 01845
Detector measures high laser power and energy densities.
Model 30(150) A-SV volume-absorbing detector head measures beam power up to 30 W continuously and 150 W intermittently. It has 100 KW/cmÃ-² damage threshold for power density and 1 J/cmÃ-² damage threshold for energy density of nanosecond pulses. Spectral range is 0.19-12 Ã-µm, power range is 50 mW to 150 W, and energy range is 50 mJ to 200 J.
Read More »Pyroelectric Detector measures very low pulse energies.
Model PE9 combines measurement of long pulses up to 15 Ã-µS with high repetition rate up to 4 kHz, in same detector head. It provides pulse energy measurements from 0.2 Ã-µJ to 1 mJ and spectral response from 0.19-12Ã-µm, in which calibration is stored in EEPROM and is selectable in 1 nm increments. With average power up to 2 W, detector features energy scales of 2Ã-µJ, 20...
Read More »CCD Laser Beam Profilers have firewire interface.
Digital BeamStar FX Series works with laptop or desktop PCs to provide everything necessary for beam profiles of pulsed and CW lasers from Ã-µW to W. System consists of camera, filters, laptop or PC card, and software. Trigger input lets BeamStar FX 33 and FX 50 synchronize with trigger output from pulsed laser. Series features automatic gain and exposure adjustment as well as automatic...
Read More »Laser Power/Energy Meter offers digital or analog display.
Compatible with thermal, pyroelectric, and photodiode heads, Nova II measures power or energy from pJ and pW to hundreds of Joules and thousands of Watts. It provides laser tuning, graphing, normalize, power or energy density units, attenuation scaling, and max/min limits. Unit offers non-volatile data storage of up to 50,000 points and includes USB and RS232 outputs. NIST traceable and CE...
Read More »Laser Measurement Head measures down to picojoule range.
Model PD10-pJ Photodiode Energy head measures laser energies from 10 pJ to 100 nJ as well as pulse rates to 4,000 Hz. It is compatible with Nova Handheld, LaserStar, Dual Channel LaserStar, and Orion-PE Handheld smart displays. Features include spectral response from 200-1,100 nm, max pulse width of 50 ns, and max average power of 0.5 W with damage threshold of 0.1/cmÃ-². Calibration accuracy...
Read More »Absorber Head offers 4-250 W measurement capability.
Model L250W thermal surface absorber head for continuous wave and long pulse lasers, measures energies from 200 mJ to 200 J. Power and energy scales are 250 W, 30 W and 200 J, 30 J, and 3 J, respectively. Large aperture, water-cooled smart head is 90 x 90 x 20 mm thick and offers power measurement accuracy of Ã-
Read More »Radiometer Head offers flat spectral response.
Suited for power measurement of broadband light sources, model PD300-BB consists of one photodiode-based detector head with flat spectral response from 400-1,000 nm. Thin, low-profile head contains 10 x 10 mm aperture with response time of 0.2 sec and low noise level of Ã-
Read More »Probe measures laser power from 200 to 10,000 W.
Comet handheld, laser power probe provides absolute accuracy of Ã-
Read More »Laser Beam Profiler allows users to adjust laser at will.
Designed to measure beam profile and power of pulsed industrial Nd:YAG and Diode industrial lasers, BA100 displays laser beam intensity profile in real time. Instrument makes measurements at full or near full power levels (1,000 W max) and is useful for looking at focal spots. Beam profile can be shown in 3D form and rotated to different angles and elevations. Unit handles pulse energies to 30...
Read More »Laser Beam Profiler works with laptop or desktop PC.
Self-contained BeamStar FX 66 provides measures CW and Pulsed lasers using laptop or desktop personal computer. Connected to PC via one Firewire interface card, product offers software with manual or automatic gain and shutter control adjustments. Laser beam focal point, vertical and horizontal spectral profiles, and beam statistics are displayed on screen. It has aperture of 9.7 x 7.68 nm, 1280...
Read More »