Viking SupplyNet

Safety & Security Equipment

Residential Sprinkler has large K factor.

Freedom® VK458 is 7.4 K factor residential pendent fire sprinkler designed to provide lowest starting pressures for NFPA 13 residential applications requiring 0.1 GPM/ftÂ-² density. Offered in brass, chrome, black, and white standard finishes, cULus-listed sprinkler may also be used in combination with smaller K factor sprinklers. It is available with surface-mounted, adjustable, and...

Read More »
Residential Fire Sprinkler helps protect smaller rooms.
Safety & Security Equipment

Residential Fire Sprinkler helps protect smaller rooms.

Freedom® VK435 is 3.1 K factor sprinkler that provides flows down to 9 gpm at room sizes of 12 x 12 ft and 10 gpm in 14 x 14 ft rooms. Offered in brass, chrome, black, and white finishes, cULus-listed sprinkler delivers flows of 20 gpm or less when 2-head design is required. It is available with surface-mounted, adjustable, and recessed escutcheons with recessed adjustments up to 5/8 in.

Read More »
Pendent Sprinkler is suited for retail environments.
Safety & Security Equipment

Pendent Sprinkler is suited for retail environments.

Suited for use in shopping malls and retail structures, K-14 Extended Coverage Ordinary Hazard (ECOH) sprinkler produces flows required to meet Ordinary Hazard density requirements at lower pressures than 8.0 or 11.2 K-factor sprinklers. UL and cUL Listed for coverage areas from 12 x 12 ft through 20 x 20 ft, sprinkler requires minimum spacing of 8 ft. When low-profile product is fully recessed,...

Read More »
Upright Sprinkler features K-factor of 16.8.
Safety & Security Equipment

Upright Sprinkler features K-factor of 16.8.

Standard response storage sprinkler, Model K-17, provides densities of .45 or greater based on 100 sq ft spacing. Available in temperatures from 155-286°F, unit is qualified for use in protection of high-piled storage. It is UL and cUL listed for Light, Ordinary, or Extra-Hazard Occupancies for hydraulically calculated wet or dry systems per NFPA 13.

Read More »
Safety & Security Equipment

Propylene Glycol System offers ESFR protection in freezers.

System K25 utilizes K25 ESFR Pendent Sprinklers and pre-mix of propylene glycol antifreeze and water. It protects up to Class II Storage Commodities in buildings up to 40 ft high with racked storage up to 35 ft. System requires minimum starting pressure of 40 psi and has maximum volume of antifreeze solution of 1,100 gallons. It provides alternative to in-rack sprinkler systems for protecting...

Read More »
Sprinkler protects combustible concealed spaces.
Safety & Security Equipment

Sprinkler protects combustible concealed spaces.

COIN(TM) Quick Response, Combustible Interstitial Space Sprinkler is tested and listed for specific light hazard combustible and non-combustible concealed horizonal spaces requiring sprinkler protection per installation standards. With coverage listings for spacing up to 12 x 12 ft, unit can be used with wet or dry pipe systmes. It has 4.2 K-factor, starting pressure of 11.8 psi at max spacing,...

Read More »
Concealed Dry Sprinklers have 5.6-8.0 K-factor.
Safety & Security Equipment

Concealed Dry Sprinklers have 5.6-8.0 K-factor.

Concealed dry pendent sprinklers include standard and quick response versions for standard and extended coverage applications. Products are made with low-zinc content brass components and utilize Belleville spring seal. Barrel and tube assemblies are epoxy-coated for additional protection. Push-on, thread-off cover is 3 1/8 in. in diameter, may be removed without taking system out of service, and...

Read More »
Deluge and Flow Control Valves are offered in 3 in. size.
Fluid & Gas Flow Equipment

Deluge and Flow Control Valves are offered in 3 in. size.

Able to be installed vertically or horizontally, UL listed and FM approved straight-through Deluge and Flow Control Valves are available in 3 configurations: flange/flange, flange/groove, and groove/groove. Painted red with galvanized trim, they are compatible with proprietary EZ or conventional trim, can be retrofitted into existing straight-through systems, and are resistant to problems caused...

Read More »
Horizontal Fire Sprinklers offer 16 x 22 ft coverage area.
Safety & Security Equipment

Horizontal Fire Sprinklers offer 16 x 22 ft coverage area.

Residential Horizontal Sidewall 4.2K Sprinklers include UL listing for residential installations below smooth, flat, horizontal ceilings at both 4-6 and 6-12 in. down from ceiling. They are also listed below sloped ceilings with up to 8/12 pitch. Available with 155°F and 175°F temperature ratings, sprinklers come in brass, chrome, and white finishes, and can be installed...

Read More »

All Topics

COVID-19 Response Suppliers COVID-19 Response:
Can Your Company Help Provide Critical Supplies?

We are using the power of our platform to aid in the mass shortage of critical supplies. If your company can help provide supplies, capabilities, or materials for products such as N-95 Masks and Tyvek SuitsPlease let us know.

COVID-19 Response Suppliers