B&K Precision Corporation

LCR/ESR Meter tests components at up to 200 kHz.
Test & Measurement

LCR/ESR Meter tests components at up to 200 kHz.

Synthesized Bench In-Circuit LCR/ESR Meter, Model 889A, utilizes standard 115 Vac outlet as power source to test components with basic accuracy of 0.1%. It provides dc/ac voltage and current measurements as well as diode/audible continuity checks. Utilizing front panel-mounted BNC connectors and test leads, user can test variety of components such as inductors, capacitors, and resistors. Dual...

Read More »
Analyzers display status of lead acid batteries.
Laboratory and Research Supplies and Equipment

Analyzers display status of lead acid batteries.

Powered by battery-under-test, hand-held Battery Capacity Analyzers provide complete analysis in 6 sec, measuring and digitally displaying percentage of capacity left in battery. With max input of 20 V, Model 601 supports 6 and 12 Vdc batteries, while Model 602 supports batteries rated 24 and 36 Vdc with max input of 50 V. Small size and portability makes analyzers suited for determining...

Read More »
Device Programmer communicates via parallel or USB port.
Electronic Components & Devices

Device Programmer communicates via parallel or USB port.

Universal Device Programmer, Model 866 comes with 48-pin ZIF socket, which eliminates need of adapter for any DIP device up to 48 pins. Buffer features include erase, random data fill, fill block, copy block, move block, swap block, buffer print, find text, replace text, 8-bit and 16-bit view modes, go to address, and checksum calculator. Model 866 is suited for anyone utilizing portable computer...

Read More »
DC Power Supply offers remote control via RS-232 interface.
Electrical Equipment & Systems

DC Power Supply offers remote control via RS-232 interface.

Utilizing switch mode technology, Model VSP6020 offers as much as 1.2 kW in 19 in. rack-mounted 1U chassis, while keeping noise levels under 20 mV. Analog remote sensing automatically maintains desired voltage at load level of power cable. With output of 0-60 Vdc/0-20 A, unit is suited for automatic test equipment, research and development labs, as well as telecommunications. Up to 9 units can be...

Read More »
DC Power Supply utilizes standard 115 Vac outlet.
Electrical Equipment & Systems

DC Power Supply utilizes standard 115 Vac outlet.

Triple-output, benchtop Model 1672 provides 2 variable voltage outputs of 0-32 Vdc/0-3 A and one fixed 5 Vdc/3 A output. It offers CV/CC operation, independent control of voltage and current for variable output, and overload indication LED for fixed output. Four panel-mounted, 3-digit displays read volts and amps of both A and B supply. Voltage meter resolution is 0.00-99.9, and amperage meter...

Read More »
Power Clamp Meter troubleshoots electrical systems.
Test & Measurement

Power Clamp Meter troubleshoots electrical systems.

Model 325 True RMS AC/DC Clamp Meter provides non-invasive measurements up to 400 kW, 400 Aac, 600 Vac, and 600 Vdc utilizing pair of standard test leads. It measures up to 4,000 ohms of resistance and 40 ohms of audible continuity. Portable, battery-powered unit includes front-panel 3Â-¾ digit LCD display, max jaw opening of 1.41 in., automatic range selection, over-range and low battery...

Read More »
Auto-Ranging LCR Meter has RS232 interface.
Test & Measurement

Auto-Ranging LCR Meter has RS232 interface.

Powered by 9 Vdc battery, handheld dual-display Model 879 measures capacitance, resistance, and inductance in 100 Hz, 120 Hz, 1 KHz, and 10 KHz test frequency ranges. Full 4Â-½ digit, backlit LCD reads values to 19,999 on each range. Unit provides simultaneous display of measured value and Q or dissipation factor. Microprocessor-controlled meter offers min/max average, relative mode, and...

Read More »
RF Counter/Detectors display frequency and signal strength.
Test & Measurement

RF Counter/Detectors display frequency and signal strength.

Hand-held Models 103, 104, 105, and 106 utilize RF and microprocessor circuitry to detect audio/video wireless transmissions. Frequency detection ranges are 1 MHz to 3 GHz, 10 Hz to 3 GHz, 1 MHz to 3 GHz, and 30 MHz to 2.8 GHz, respectively. Users can simultaneously view signal strength on 16-section bargraph and detected frequency on LCD screen. All units include 4 selectable gate speeds,...

Read More »
Signal Generator supplies clean, accurate waveforms.
Agricultural & Farming Products

Signal Generator supplies clean, accurate waveforms.

Model 3003 hand-held, 10 MHz, Sine and Square Wave Generator offers frequency accuracy of 0.02% with 0.1 Hz settability. Eight push wheel switches enable user to set frequency. Unit operates from external AC adapter or standard 9 V battery. Front panel mounted controls and indicators include on/off power switch, LED power indicator, output level control, sine connector, square connector, and...

Read More »
Clamp Meter operates in tight quarters.
Test & Measurement

Clamp Meter operates in tight quarters.

Model 316 AC/DC Milliamp Clamp Meter provides safe, non- invasive measurement of up to 100 Aac, 100 Adc, 600 Vac, 600 Vdc, and Resistance up to 10 Kohm. Portable, digital unit features 4-digit LCD display, auto power off after 30 min, auto ranging, peak hold, data hold, and touch zero function. Resolution is 1 mA with minimum input of 70 mA. Maximum jaw opening is 0.49 in. Meter utilizes two AAA...

Read More »

All Topics

COVID-19 Response Suppliers COVID-19 Response:
Can Your Company Help Provide Critical Supplies?

We are using the power of our platform to aid in the mass shortage of critical supplies. If your company can help provide supplies, capabilities, or materials for products such as N-95 Masks and Tyvek SuitsPlease let us know.

COVID-19 Response Suppliers