Electro-Chemical Devices, Inc.

S80 pH Analyzer System features 10 different pH electrode cartridges.
Laboratory and Research Supplies and Equipment

S80 pH Analyzer System features 10 different pH electrode cartridges.

Designed with Valve Retractable configuration, S80 pH Analyzer Sensors facilitates retraction and insertion into flowing pipe using compression and ball valves. Sensors come with pre-caliberation, allowing two way communication with T80 transmitter and ensures easy pH monitoring. Fabricated with 316L stainless steel with VITON O-rings, S80 PH analyser system is suitable for rugged industrial...

Read More »
Colorimetric Analyzer Monitors Hazardous Chromium VI in Drinking Water
Laboratory and Research Supplies and Equipment

Colorimetric Analyzer Monitors Hazardous Chromium VI in Drinking Water

Ideal for Muni Water Treatment Processes Anaheim, CA - August 29, 2016 - Municipal water treatment engineers who must monitor chromium VI in drinking water will find the CA6 Colorimetric Analyzer from Electro-Chemical Devices provides precise and dependable measurement to ensure compliance with local, state and federal drinking water standards. According to the U.S. Environmental Protection...

Read More »
Ozone Analyzer features reagent-less sensor design.
Laboratory and Research Supplies and Equipment

Ozone Analyzer features reagent-less sensor design.

Factory assembled and calibrated, Model OZ80 uses amperometric sensors to detect and monitor O3 levels in water. Plumb and play design only requires user to mount panel, connect drain lines, plug in power cord, and select outputs on display as 0–2.0 ppm for water disinfection or 0-20.00 ppm for oxidation and bleaching operations. Constant head flow control device maintains optimum flow rate for...

Read More »
Spectroscopic Analyzers measure single or dual parameters.
Laboratory and Research Supplies and Equipment

Spectroscopic Analyzers measure single or dual parameters.

Suitable for water/wastewater applications, CA-6 UV Analyzers can monitor any 2 selected parameters in separate measurement ranges for ammonia, nitrate, or chemical oxygen demand (COD 254 nm). Each parameter is analyzed based on measurement of UV absorption in sample. Absorbance of solution or gas is measured through quartz flow cell at specific wavelength using Xenon lamp and photo detectors....

Read More »
Peracetic Acid Analyzer helps maintain disinfection.
Laboratory and Research Supplies and Equipment

Peracetic Acid Analyzer helps maintain disinfection.

Featuring plumb-and-play design that incorporates constant head flow control device, pH sensor, peracetic acid sensor, andÂ- T80 analyzer/transmitter, PA80 Peracetic Analyzer ensures disinfection without need for potentially harmful disinfection byproducts. Panel-mounted unit provides multiple measurement ranges of 0–20, 0–200, and 0–2,000 ppm to best meet application...

Read More »
Modular Analyzer automates aquaculture monitoring.
Laboratory and Research Supplies and Equipment

Modular Analyzer automates aquaculture monitoring.

Featuring modular, plug-and-play design, T80-S80 Analyzer System automates testing for dissolved oxygen, pH, ammonia, and other parameters. Rackmount T80 Transmitter, equipped with 2Â-¾ x 1½ in. LCD, is available in loop powered, 24 Vdc line powered, or 110/220 Vac line powered modes. DO80 DO Sensor features measurement range from 0.00–20.00 ppm over temperature range of -10 to...

Read More »
Total Chlorine Analyzer simplifies water monitoring.
Laboratory and Research Supplies and Equipment

Total Chlorine Analyzer simplifies water monitoring.

Utilizing 3-electrode amperometric sensor, plug-n-play TC-80 monitors total chlorine in drinking water, rinse water, cooling water, or other fresh water samples from 0.05–20 ppm chlorine as standard or 0.005–2.000 ppm with low range sensor. Panel mount design includes built-in flow control and automatic pH compensation. Available with 110-240 Vac or 24 Vdc power, TC-80 graphically displays...

Read More »
De-Chlorination Analyzer measures near 0 levels of chlorine.
Laboratory and Research Supplies and Equipment

De-Chlorination Analyzer measures near 0 levels of chlorine.

Utilizing zero-shift method to ensure stable chlorine measurement,Â- plug-n-play DC80 is suited for municipal water systems and industrial cooling water. Unit monitors chlorine from 0.05–20 ppm and includes built-in automatic pH compensation for samples from 4–12 pH. Available with 110–240 Vac or 24 Vdc power, analyzer features dual measurements, two 4–20 mA outputs,...

Read More »
Transmitter and Analyzer measure turbidity and DO or pH.
Electrical Equipment & Systems

Transmitter and Analyzer measure turbidity and DO or pH.

Dual-channel T80 Universal Transmitter and Triton TR6 Turbidity Analyzer serve wastewater treatment technicians who need to measure turbidity and dissolved oxygen (DO) or pH levels in secondary clarifiers. Products canÂ- work with S80 Intelligent Sensors to measure DO, pH, or 5 other liquid parameters. While T80 features self-configuring electronics and eliminates need for multiple...

Read More »
Sulfide Analyzer helps control odor and protect equipment.
Laboratory and Research Supplies and Equipment

Sulfide Analyzer helps control odor and protect equipment.

Utilizing sulfide ion selective electrode, Model SMS-22 provides user-selectable automated sequential sampling of sulfide ions in water. Multi-step process includesÂ- conditioning sample, measuring sulfide, neutralizing sample, measuring pH, and draining and rinsing cell. Offering adjustable sampling times from 2–10 samples/hr, system features measurement range of 0–5 ppm and up to 500...