Aprima Medical Software, Inc

HVAC Drives can be programmed for any application.

HVAC Drives can be programmed for any application.

MCH Series can be used for centrifugal fans, blowers, pumps and cooling towers. Programming is via front panel keypad and 32-character, 2-line, English language backlit display. Drives have PID control, V/Hz profile for centrifugal loads, 66 programmable parameters, and RS485 communications. Options include input disconnect or circuit breaker, line reactor, and manual or automatic three-contactor...

Read More »
Control System optimizes engine performance.
Controls & Controllers

Control System optimizes engine performance.

Engenius ESM Engine System Manager, directed by Engine Control Unit (ECU) monitors speed, pressure, temperature and other engine conditions; controlling ignition timing, speed governing and stop/start functions. It also provides diagnostic help and fault logging when requested. System can be packaged to instantly communicate to Internet server, computer, phone or pager via satellite, cellular...

Read More »
Electrical Equipment & Systems

Transmitters provide turn-key continuous level measurement.

+GF+ SIGNET 8250 ProcessPro(TM) Level Transmitters feature single or dual-channel input with one 4 to 20mA output for each input channel. All outputs are fully scaleable and reversible. Transmitters come equipped with 2 relays and ability to support 2 additional externally mounted relays. Suited for continuous level and volume monitoring requirements, instruments can be used locally or remotely...

Read More »
Isolation Valve mounts directly on manifold.
Fluid & Gas Flow Equipment

Isolation Valve mounts directly on manifold.

Two-way solenoid valve mounts on manifold, is rated up to 35 psi with Cv of 0.05, and is available in 12 and 24 Vdc models, in normally open or normally closed versions. Materials in contact with flow path are limited to PEEK (polyetheretherketone) and EPDM (ethylene propylene) or FKM (highly-fluorinated fluorocarbon). Applications include blood analysis, clinical chemistry, DNA processing,...

Read More »
Inert Valve controls corrosive or high-purity fluids.
Fluid & Gas Flow Equipment

Inert Valve controls corrosive or high-purity fluids.

Solenoid-operated IPV inert proportional diaphragm isolation valve can be used in medical equipment, water purification and clinical chemistry industries. Materials of all surfaces in flow path are inert and impervious to wide range of aggressive fluids. Valve provides infinitely variable flow control, is rated to 60 psi, and has 24 Vdc driver. Poppet and seat are configured to provide bubble...

Read More »
Inert Diaphragm Valve handles aggressive fluids.
Fluid & Gas Flow Equipment

Inert Diaphragm Valve handles aggressive fluids.

Three-way IDV solenoid-operated diaphragm isolation valve works with fluids found in medical equipment, water purification and clinical chemistry industries. Materials of all surfaces in flow path are inert and impervious to many aggressive fluids. Valve is typically used in waste circuits where valve must tolerate high contaminant levels. Valve is rated 35 psi with Cv of 0.22 and is available in...

Read More »
Through-port Valves control and shut off flow.
Fluid & Gas Flow Equipment

Through-port Valves control and shut off flow.

Stargate-O-Port valves work with ultrasonic positioner to control flow. Different port and orifice shapes allow selecting certain characteristics of flow cross section and blade position. Valves also serve as line blind in maintenance situations, to take out pipes and set blank flanges for safety. They have tight class VI shut-off which allows operators to close valve, inset locking pin and pad...

Read More »