        <item>
            <title>Medium-Voltage Switchgear is designed for wind turbines.</title>
            <link>http://news.thomasnet.com/fullstory/559301</link>
            <description>
Operating at 36 kV, NX Plus C Wind has compact design that can be readily accommodated in wind turbine towers. This gas-insulated switchgear installs in base of wind turbine tower and can fit through its door. In most applications, wind turbine with its generator supplies electrical energy at 690 V. Downcircuit converter matches frequency to wind farm's network and ensures stable voltage level. Transformer steps this up to 30 or 33 kV to minimize transmission losses.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=559301&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/green-clean' target='_blank''&gt;Green &amp; Clean&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/mechanical-power-transmission' target='_blank''&gt;Mechanical Power Transmission&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/medium-voltage-switchgear-82063850-1.html' target='_blank''&gt;Medium Voltage Switchgear&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/wind-turbines-89570907-1.html' target='_blank''&gt;Wind Turbines&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 22 Apr 2009 08:31:46 -0500</pubDate>
        </item>
        <item>
            <title>Switchgear mounts directly on indoor busbar systems.</title>
            <link>http://news.thomasnet.com/fullstory/820860</link>
            <description>
Rittal Ri4Power type-tested low-voltage switchgear can be mounted directly on RiLine60 indoor busbar systems using device, connection, or circuit breaker adapters. It can be used to install IEC-compliant switchgear with form separation up to Form 4 and busbar systems up to 4,000 A. Direct access to fully-insulated busbars in relevant functional space enables switchgear's terminal points and corresponding connection cables to be reached quickly from front for maintenance.

&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=820860&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/low-voltage-switchgear-82063702-1.html' target='_blank''&gt;Low Voltage Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 29 Sep 2008 07:38:21 -0500</pubDate>
        </item>
        <item>
            <title>Loadcenters feature in-board neutral capabilities.</title>
            <link>http://news.thomasnet.com/fullstory/502342</link>
            <description>
Designed for residential electrical contract jobs, Premium CH loadcenters are available with Cutler-Hammer&amp;#174; plug-on neutral arc-fault circuit interrupter (AFCI) and ground-fault circuit interrupter (GFCI) to reduce installation time. Options eliminate need to wire neutral of breaker to neutral bar due to addition of metal stab on breaker that clips onto inboard neutral bar of loadcenter. Products also accept all standard CH circuit breakers.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=502342&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/loadcenters-44573509-1.html' target='_blank''&gt;Loadcenters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 08 Jan 2007 07:49:53 -0500</pubDate>
        </item>
        <item>
            <title>Switchgear offers zone-based protection and mobile metering.</title>
            <link>http://news.thomasnet.com/fullstory/474500</link>
            <description>
Ranging from 208-600 V/800-5,000 A, Entellisys(TM) provides synchronized, waveform capture from every circuit simultaneously, within microseconds, enabling fault reports and event logs before, during, and after event for each breaker. Users can set up to 600 alarm conditions for which Entellisys will send information to designated devices. Operators can perform control, monitoring, and diagnostic work outside arc-flash protection boundary using remote HMI options.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=474500&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/low-voltage-switchgear-82063702-1.html' target='_blank''&gt;Low Voltage Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 03 Feb 2006 04:52:30 -0500</pubDate>
        </item>
        <item>
            <title>Power Distribution Module suits high-current applications.</title>
            <link>http://news.thomasnet.com/fullstory/462211</link>
            <description>Multiplexed Vehicle Electrical Center (mVEC) features up to 30 A per channel, to max of 200 A. As a networked controller and power distribution module, mVEC alerts operator to any system deficiency by sending information on status of relays and fuses via data bus to any networked display or telltale module. It can address vehicle multiplexing through J1939/CAN interface and other standard protocols. Unit is suitable for construction, agriculture, and heavy trucking.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=462211&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/power-distribution-switchgear-82064502-1.html' target='_blank''&gt;Power Distribution Switchgear&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/power-distribution-units-62590203-1.html' target='_blank''&gt;Power Distribution Units&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 18 Apr 2005 07:48:14 -0500</pubDate>
        </item>
        <item>
            <title>Vacuum Reclosers offer direct SEL 351R compatibility.</title>
            <link>http://news.thomasnet.com/fullstory/461221</link>
            <description>Three-phase TriMod&amp;#226;&amp;quot;&amp;#162; 300R Series requires only one control cable for full functionality and provides twice the duty cycle required by ANSI C.37.60. Solid-dielectric insulation system minimizes environmental problems associated with typical oil and gas insulation. Removable current transformers are surrounded by grounded metal surface, providing added personnel and equipment safety. Operating mechanism delivers 10,000 maintenance-free operations.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=461221&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/reclosers-96109871-1.html' target='_blank''&gt;Reclosers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/vacuum-switches-82060401-1.html' target='_blank''&gt;Vacuum Switches&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 16 Mar 2005 07:43:46 -0500</pubDate>
        </item>
        <item>
            <title>Power Distribution Switch has input voltage of 0.8 V.</title>
            <link>http://news.thomasnet.com/fullstory/31621</link>
            <description>MIC2044/45 Protected High-Side Power Switch features 30 mOhm maximum On-resistance and operating range of 0.8-5.5 V with continuous output current of 6 A. Other features include programmable current limit, short circuit protection, thermal shutdown, adjustable slew rate control, fault status flag, under-voltage lockout, and low quiescent current. Applications include PCs, laptops, PDAs, docking stations, LAN servers, WAN switches, base stations, and RAID controllers.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=31621&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/power-switches-81951154-1.html' target='_blank''&gt;Power Switches&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/power-distribution-switchgear-82064502-1.html' target='_blank''&gt;Power Distribution Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 18 Mar 2004 07:40:17 -0500</pubDate>
        </item>
        <item>
            <title>Vacuum Switchgear installs in any position.</title>
            <link>http://news.thomasnet.com/fullstory/18230</link>
            <description>VACpac&amp;#174; switchgear features non-combustible insulating medium, SF&amp;lt;sub&amp;gt;6&amp;lt;/sub&amp;gt; gas, and can be used indoors or outdoors. It fits through manholes and vault access openings, and mounts on walls, floors, or ceilings. VACpac suits system applications up to 35 kV. It can switch or sectionalize load, loop underground systems, perform source transfers, and provide tap overcurrent protection. Capacitor switching duty cycle is greater than 7,000 operations.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=18230&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Sat, 27 Dec 2003 00:00:00 -0500</pubDate>
        </item>
        <item>
            <title>Reclosers offer vacuum interruption and DA capabilities.</title>
            <link>http://news.thomasnet.com/fullstory/25737</link>
            <description>Kyle&amp;#174; PWE and PWVE pad-mounted, 3-phase, automatic circuit reclosers provide overcurrent protection for distribution systems that use underground cable. Offered with microprocessor controls, products suit 15 and 27 kV systems that include overhead and underground construction on one feeder. PWE types protect 3-phase systems rated 2.4&amp;#226;¤&amp;quot;14.4 kV, and PWVE types can be applied to systems rated through 24.9 kV.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=25737&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/reclosers-96109871-1.html' target='_blank''&gt;Reclosers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 25 Aug 2003 08:00:51 -0500</pubDate>
        </item>
        <item>
            <title>Paralleling Switchgear Control streamlines operator control.</title>
            <link>http://news.thomasnet.com/fullstory/25546</link>
            <description>Entellisys Pro&amp;#226;&amp;quot;&amp;#162; allows one operator, from one location, to monitor and control entire facility&amp;#226;¤(TM)s power distribution system. It increases system redundancy to maximize uptime and minimize interruptions. In emergency situations, each generator automatically starts and parallels itself to generator bus. Features include built-in SCADA system, data tracking and timing, automatic generator kW and kVar soft loading capabilities, GE governor controller, and built-in VAR/pf controller.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=25546&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/generator-control-switchgear-82062902-1.html' target='_blank''&gt;Generator Control Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 18 Aug 2003 07:55:16 -0500</pubDate>
        </item>
        <item>
            <title>Distribution Switchgear does not use gas or oil insulation.</title>
            <link>http://news.thomasnet.com/fullstory/24266</link>
            <description>Kyle&amp;#174; NOVA&amp;#226;&amp;quot;&amp;#162; encases vacuum interrupter in cycloaliphatic epoxy to eliminate need for insulating fluid, gas, or foam. Requiring no maintenance throughout life of product, unit has polymer casing that resists UV radiation. It maintains self-cleaning, unblemished surface with low adhesion to contaminants. Polymer also resists tracking, reducing flashovers. NOVA technology is available in Cooper Kyle switches, sectionalizers, and reclosers.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=24266&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/distributed-or-dispersed-generation-switchgear-82062704-1.html' target='_blank''&gt;Distributed or Dispersed Generation Switchgear&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/switchgear-82061409-1.html' target='_blank''&gt;Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 09 Jul 2003 07:47:15 -0500</pubDate>
        </item>
        <item>
            <title>Switchgear offers transient voltage surge suppression.</title>
            <link>http://news.thomasnet.com/fullstory/19081</link>
            <description>POWER-ZONE&amp;#174; 4 Switchgear offers SURGELOGIC&amp;#174; TVSS Surge Protection Devices as integral components or external add-ons, providing peak amperage protection up to 480 kA. Integral TVSS device, with modular design, does not require extra lengths of conductor. Externally mountable TVSS devices protect single pieces of equipment and can be used alone or in conjunction with internal devices. Switchgear offers segregated access to wiring and smart functionality.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=19081&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/switchgear-82061409-1.html' target='_blank''&gt;Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 10 Feb 2003 07:40:07 -0500</pubDate>
        </item>
        <item>
            <title>Switchgear has high current rating.</title>
            <link>http://news.thomasnet.com/fullstory/16606</link>
            <description>HVL/cc&amp;#174; Medium Voltage Metal-Enclosed Switchgear provides increased capacity with 1200 A continuous current rating at 5&amp;#226;¤&amp;quot;17.5 kV, making it suitable for main-feeder, main-tie-main lineups in plant and building applications. Isolated bus, cable, and main switch compartments prevent access to live parts while changing fuses. Electrical life is increased to 26 full load and 1000 mechanical operations.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=16606&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/medium-voltage-switchgear-82063850-1.html' target='_blank''&gt;Medium Voltage Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 19 Nov 2002 07:44:11 -0500</pubDate>
        </item>
        <item>
            <title>Switchgear improves linemen safety.</title>
            <link>http://news.thomasnet.com/fullstory/15414</link>
            <description>Kyle&amp;#174; VFI Vacuum Fault Interrupter pad-mounted switchgear with Visible-Break provides positive visual verification of contact status when distribution-switching procedures require indication of open circuit prior to testing and verification. Visible-Break feature is available in 2-position (open/closed) and 3-position (open/close/ground) configurations with ground switch capabilities. Unit meets switching and protection requirements for 5, 15, 25, and 35 kV underground systems.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=15414&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/switchgear-82061409-1.html' target='_blank''&gt;Switchgear&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 17 Oct 2002 07:37:43 -0500</pubDate>
        </item>