<?xml version="1.0" encoding="iso-8859-1"?>
<!-- generator="FeedCreator 1.7.1" -->
<rss version="2.0">
    <channel>
        <title>ThomasNet Industrial Newsroom - </title>
        <description>ThomasNet Industrial Newsroom is a service of ThomasNet.com</description>
        <link>http://news.thomasnet.com</link>
        <lastBuildDate>Sat, 06 Sep 2008 01:33:23 -0500</lastBuildDate>
        <generator>FeedCreator 1.7.1</generator>
        <image>
            <url>http://news.thomasnet.com/images/RSS_logo.gif</url>
            <title>Powered by ThomasNet Industrial Newsroom</title>
            <link>http://news.thomasnet.com</link>
            <width>144</width>
            <height>31</height>
            <description>ThomasNet Industrial Newsroom is a service of ThomasNet.com</description>
        </image>
        <item>
            <title>Conductivity Level Probes resist heat and corrosion.</title>
            <link>http://news.thomasnet.com/fullstory/548653</link>
            <description>
Mounted in any orientation in tank, tee fitting, or any compatible threaded port, Series CLP determines presence of conductive liquid at set level by sensing conductivity. Probes allow for measurement of conductivity between probe fitting and end, which is isolated by ceramic insulator, or between ends of 2 probes. Offered with &amp;#194;&amp;#189; in. NPT process connection, probes feature solid stainless steel end for resistance to heat and corrosion.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1648&amp;prid=548653&amp;cat=2399&amp;goto=http%3A%2F%2Fwww.keyence.com%2FINRS'&gt;Keyence Corporation of America - The Internet Resource for Sensor Solutions&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/conductivity-sensors-73741944-1.html' target='_blank''&gt;Conductivity Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/liquid-level-probes-96023072-1.html' target='_blank''&gt;Liquid Level Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 28 Aug 2008 07:42:19 -0500</pubDate>
        </item>
        <item>
            <title>Capacitance Level Sensor features RF immunity.</title>
            <link>http://news.thomasnet.com/fullstory/512342</link>
            <description>
Operating at 6 kHz, PROCAP Series provides level measurement by using timing technique that compares discharge time of probe capacitance to reference capacitance. PRO-Shield guards against false readings from buildup by forcing active signal to examine large area around probe, while time delay readings minimize false signals from sudden material shifts or splashing liquids. External LED indicates whether probe is covered, uncovered, or in failed condition.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1648&amp;prid=512342&amp;cat=2399&amp;goto=http%3A%2F%2Fwww.keyence.com%2FINRS'&gt;Keyence Corporation of America - The Internet Resource for Sensor Solutions&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/liquid-level-sensors-73747107-1.html' target='_blank''&gt;Liquid Level Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/capacitive-sensors-73741811-1.html' target='_blank''&gt;Capacitive Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/liquid-level-probes-96023072-1.html' target='_blank''&gt;Liquid Level Probes&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/capacitive-probes-96066659-1.html' target='_blank''&gt;Capacitive Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 15 Mar 2007 07:49:04 -0500</pubDate>
        </item>
        <item>
            <title>Probes use ultrasound or radar to measure fill levels.</title>
            <link>http://news.thomasnet.com/fullstory/454765</link>
            <description>
Two-conductor, Sitrans Probes LU and LR continually measure fill level of storage tanks and process vessels, as well as flow rate in open flumes. Interference echoes are automatically filtered out to ensure reliable analysis of echo signals. Ultransonic transceiver, Model LU offers 12 m measuring range in liquids and slurries, while radar level transmitter, Model LR operates at 5.8 GHz or in North America at 6.3 GHz with measuring range of 0.3-20 m.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/communication-systems-equipment' target='_blank''&gt;Communication Systems and Equipment&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/computer-hardware-peripherals' target='_blank''&gt;Computer Hardware and Peripherals&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1648&amp;prid=454765&amp;cat=2399&amp;goto=http%3A%2F%2Fwww.keyence.com%2FINRS'&gt;Keyence Corporation of America - The Internet Resource for Sensor Solutions&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/level-transmitters-95947909-1.html' target='_blank''&gt;Level Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/transceivers-86930203-1.html' target='_blank''&gt;Transceivers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/liquid-level-probes-96023072-1.html' target='_blank''&gt;Liquid Level Probes&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ultrasonic-probes-63560478-1.html' target='_blank''&gt;Ultrasonic Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Fri, 20 Aug 2004 07:39:54 -0500</pubDate>
        </item>
        <item>
            <title>Pulse Radar Probes are noiseless and self-adjusting.</title>
            <link>http://news.thomasnet.com/fullstory/17384</link>
            <description>Pulse Radar Probes, used for distances of 50 and 100 ft, offer very low noise performance due to operation of receiver, which is activated by incoming echoes from wanted targets. Units adjust microwave pulse amplitude and width to target distance and reflection properties. Receiver changes sensitivity with amplitude of received echoes. Shapes of received echoes are analyzed to eliminate echoes coming from tank's walls, standpipes, and other obstructions.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1648&amp;prid=17384&amp;cat=2399&amp;goto=http%3A%2F%2Fwww.keyence.com%2FINRS'&gt;Keyence Corporation of America - The Internet Resource for Sensor Solutions&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/liquid-level-probes-96023072-1.html' target='_blank''&gt;Liquid Level Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 11 Dec 2002 08:12:55 -0500</pubDate>
        </item>
        <item>
            <title>Ultrasonic Level Probe offers 90 ft range.</title>
            <link>http://news.thomasnet.com/fullstory/17385</link>
            <description>Model ABM300/400-25U(C) measures liquids and solids up to 90 ft. It operates with phase array structure ultrasonic transducer, which offers narrow no side lobes beam, 17 in. blanking, and same operation at different temperatures. Self-cleaning probe can replace expensive ultrasonic or microwave level gauges. &lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1648&amp;prid=17385&amp;cat=2399&amp;goto=http%3A%2F%2Fwww.keyence.com%2FINRS'&gt;Keyence Corporation of America - The Internet Resource for Sensor Solutions&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/liquid-level-probes-96023072-1.html' target='_blank''&gt;Liquid Level Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 11 Dec 2002 08:12:55 -0500</pubDate>
        </item>
        <item>
            <title>Ceramic Probe withstands temperatures of 450&amp;#194;&amp;#176;F.</title>
            <link>http://news.thomasnet.com/fullstory/15665</link>
            <description>Radio frequency sensing probe is suited for applications where temperatures exceed 450&amp;#194;&amp;#176;F. Made of 304 Stainless Steel and ceramic, this probe is mounted remote from electronics, providing maximum protection from heat. Probes available for higher temperature applications include heavy duty probe with larger diameter active section, which accepts various extensions and attachments for unique applications.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1648&amp;prid=15665&amp;cat=2399&amp;goto=http%3A%2F%2Fwww.keyence.com%2FINRS'&gt;Keyence Corporation of America - The Internet Resource for Sensor Solutions&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/liquid-level-probes-96023072-1.html' target='_blank''&gt;Liquid Level Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 30 Oct 2002 07:40:14 -0500</pubDate>
        </item>
    </channel>
</rss>
