        <item>
            <title>Vane Anemometer Pens feature 3/8 in. LCD digits on display.</title>
            <link>http://news.thomasnet.com/fullstory/829180</link>
            <description>
Available in 3 different units, Traceable&amp;#174; vane anemometer pens provide for airflow, temperature, humidity, dew point, and barometric pressure. Units come with o-ring seal and membrane keypad to keep out dust and dirt, and HOLD button to freeze reading on display. Available in rugged ABS plastic case measuring 1&amp;#189; x 8&amp;#188; x 1&amp;#189; in. and weighing 6 oz, they can recall minimum/ maximum readings. Applications include laboratories, manufacturing, petroleum, and pharmaceutical industry.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-meters-51070902-1.html' target='_blank''&gt;Pressure Meters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-measurement-instruments-761908-1.html' target='_blank''&gt;Air Flow Measurement Instruments&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/anemometers-1710201-1.html' target='_blank''&gt;Anemometers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/dew-point-meters-50893056-1.html' target='_blank''&gt;Dew Point Meters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-meters-51082303-1.html' target='_blank''&gt;Temperature Meters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-meters-51031557-1.html' target='_blank''&gt;Humidity Meters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 25 Aug 2009 08:27:39 -0500</pubDate>
        </item>
        <item>
            <title>Flow Sensor has measuring range of 0-50 m/s.</title>
            <link>http://news.thomasnet.com/fullstory/823958</link>
            <description>
Model SS 20.260 immersion sensor with integrated transducer measures free and guided air in ducts from 1-40 in. long at temperatures up to 120&amp;#176;C. It operates from 24 Vdc supply, consumes 30 mA, and provides 4-20 mA linear output. Two status LEDs indicate correct operation or indicate wrong supply voltage or sensor defects. Sensor can be used to measure flow of air, nitrogen, argon, and non-burnable gases.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-flow-sensors-97002004-1.html' target='_blank''&gt;Gas Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/high-temperature-sensors-95935227-1.html' target='_blank''&gt;High Temperature Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 19 Feb 2009 08:34:17 -0500</pubDate>
        </item>
        <item>
            <title>Duct-Mounted Station measures airflow in turbulent conditions.</title>
            <link>http://news.thomasnet.com/fullstory/555968</link>
            <description>
Designed to measure airflow in duct systems with turbulent conditions at point of measurement, Series STRA delivers accuracy to within 2% of actual flow over 100-10,000 fpm velocity range. It consists of single or multiple airflow elements, factory-mounted and pre-piped in casing designed for flanged connection to ductwork. Also included, airflow straightening section, using honeycombing with &amp;#189; in. opening x 3 in. depth, is made of 3003 aluminum.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-measuring-stations-95982054-1.html' target='_blank''&gt;Air Flow Measuring Stations&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 16 Feb 2009 09:09:49 -0500</pubDate>
        </item>
        <item>
            <title>Air Flow Measuring Probes are suited for duct applications.</title>
            <link>http://news.thomasnet.com/fullstory/555473</link>
            <description>
Exhibiting overall accuracy of &amp;#177;2%, Series DAFM probes use evenly distributed total and static pressure measuring points to determine air flow in ducts. They are constructed with wetted materials of aluminum, featuring clear anodized finish, and intended for installation from completely outside of fan, promoting use in HVAC industry. Available to fit ducts with diameters from 6-96 in., probes have respective max temperature and flow ratings of 400&amp;#176;F and 12,000 fpm.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 05 Feb 2009 08:45:29 -0500</pubDate>
        </item>
        <item>
            <title>Probes measure air flow at inlet section of fan.</title>
            <link>http://news.thomasnet.com/fullstory/552807</link>
            <description>
Series FAFM Fan Inlet Air Flow Measuring Probes utilize evenly distributed total and static pressure measuring points to measure flows in fan inlet. Installed from outside of fan, lightweight, durable units can be ordered to fit inlets with diameters ranging from 6-96 in.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-probes-63558688-1.html' target='_blank''&gt;Pressure Probes&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-measuring-probes-95982047-1.html' target='_blank''&gt;Air Flow Measuring Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 28 Nov 2008 07:45:51 -0500</pubDate>
        </item>
        <item>
            <title>Pressure Sensors suit furnace modulation applications.</title>
            <link>http://news.thomasnet.com/fullstory/822141</link>
            <description>
Designed to measure airflow, P992 features pressure ranges of 0-2 to 0-10 in. H&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;0, ceramic MEMS sense element, and plastic composite housing. Model P356 features ceramic capacitive sense element, brass housing, pressure range of 0.5 to 0-5 psi gauge/differential, and is suited for measuring propane or natural gas flow. Fully temperature compensated P992 and P356 offer 0.25-0.45 and 0.5-4.5 Vdc linear amplified output proportional to pressure, respectively.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/flow-sensors-73744104-1.html' target='_blank''&gt;Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-sensors-73751604-1.html' target='_blank''&gt;Pressure Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-flow-sensors-97002004-1.html' target='_blank''&gt;Gas Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 20 Nov 2008 07:54:08 -0500</pubDate>
        </item>
        <item>
            <title>Airflow/Air Temperature Measurement Device has 0.5 mm head.</title>
            <link>http://news.thomasnet.com/fullstory/820209</link>
            <description>
With miniature 0.5 mm omni-directional sensor head remotely located on 2 m cable, Cambridge AccuSense PointFlow features digital display showing airflow in fpm or m/sec, and ability to download readings through serial or analog output. Microhead causes no distortion of airflow making unit suitable for measuring low airflow in tight spaces such as those found in small electronic devices. Device uses pulse technology to provide airflow and temperature measurement simultaneously.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-measurement-instruments-761908-1.html' target='_blank''&gt;Air Flow Measurement Instruments&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-measurement-equipment-84159607-1.html' target='_blank''&gt;Temperature Measurement Equipment&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 02 Sep 2008 07:41:36 -0500</pubDate>
        </item>
        <item>
            <title>Air Flow Sensor comes with integrated dual color display.</title>
            <link>http://news.thomasnet.com/fullstory/819570</link>
            <description>
Available in 3 port sizes with total of 8 flow rate ranges of 0.5-1,000 Lpm, FM-200 Series is bi-directional digital flow sensor for use with air or Nitrogen gas that offers high precision detection of 3% F.S. Unit utilizes 2 temperature sensors, one on each side of a heater element, to determine heat distribution, providing accurate detection, regardless of flow direction. It has ability to display real time flow rate of any process and can function as a flow meter.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/digital-sensors-96078746-1.html' target='_blank''&gt;Digital Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/digital-meters-50893254-1.html' target='_blank''&gt;Digital Meters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/flow-sensors-73744104-1.html' target='_blank''&gt;Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 13 Aug 2008 07:43:40 -0500</pubDate>
        </item>
        <item>
            <title>Tunnel measures passive airflow volume in micro range.</title>
            <link>http://news.thomasnet.com/fullstory/819405</link>
            <description>
Cambridge AccuSense MicroFlow Tunnel provides accurate and repeatable airflow volume measurements from 0.60-6.00 scfm through densely populated electronics packaging. Suited for design engineers, device can be used to validate air flow through phones, laptops, portable medical diagnostic equipment, or other small electronic devices, and provides accurate way to measure micro air volumes typical of passive airflow cooling and ensures thermal reliability of these devices.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-measurement-instruments-761908-1.html' target='_blank''&gt;Air Flow Measurement Instruments&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 01 Aug 2008 07:36:48 -0500</pubDate>
        </item>
        <item>
            <title>Flow Sensor handles temperatures up to 350&amp;#176;C.</title>
            <link>http://news.thomasnet.com/fullstory/545250</link>
            <description>
Offering measuring range of 0.2-20 m/sec, Model SS 20.60 HT provides digital and analog output and uses status indicator to display information about current flow velocity. Modular design enables sensor to be supplied with field bus interface. Able to measure free air and guided air in ducts from 25-1.000 mm, sensor is suited for mass flow control of combustion processes, burner control, flow measurement of process gases, and volume flow measurement of test stands.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/flow-sensors-73744104-1.html' target='_blank''&gt;Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 12 Jun 2008 07:35:31 -0500</pubDate>
        </item>
        <item>
            <title>Thermal Flow Sensor can withstand explosive environment.</title>
            <link>http://news.thomasnet.com/fullstory/816151</link>
            <description>
Featuring 9 mm SS tube, SS 23.400 ATEX3 Thermal Flow Sensor can measure flow velocity and detect direction of clean air and gas flow. It offers atmospheric pressure range of 700-1,300 hPa and power supply range of 12-24 Vdc. Including 2 switching outputs to indicate flow direction and limit value, microcontroller based unit provides serial interface that allows on-site programming via PC and adaptation of response time, threshold, and switching polarity to operation requirements.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-sensors-73744856-1.html' target='_blank''&gt;Gas Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/thermal-sensors-95970349-1.html' target='_blank''&gt;Thermal Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 11 Apr 2008 07:44:53 -0500</pubDate>
        </item>
        <item>
            <title>MEMS Flow Sensor suits HVAC air handling equipment.</title>
            <link>http://news.thomasnet.com/fullstory/809109</link>
            <description>
Model D6F-P MEMS Flow Sensor incorporates cyclone-type dust segregation system with bidirectional flow paths that generate cyclonic flows to separate dust particles from air using centrifugal forces. It offers flow range of +1.0 SLM, pressure range of +0.84 in. H&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;O, and output signal range of analog 0.5-2.5 Vdc, with 0-0.5 Vdc indicating negative flow. Measuring 17 x 37 x 27 mm, unit is available in PCB mountable and connector models.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 14 Jan 2008 07:28:28 -0500</pubDate>
        </item>
        <item>
            <title>Air and Gas Flow Sensor has 200 m/s measuring range.</title>
            <link>http://news.thomasnet.com/fullstory/502044</link>
            <description>
Featuring 1:1,000 turn-down ratio, SS 20.60 immersion-style sensor incorporates media-resistant sensor tip and modular design that allows for selection of analog, Profibus-DP, or Device-Net interface. Calibration accuracy is 1% of measuring value, and max operating pressure is 230 psig. Compact sensor with attached transformer measures air, nitrogen, CO2, and other gases and can be used in 1-40 in. tubes.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/flow-sensors-73744104-1.html' target='_blank''&gt;Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 02 Jan 2007 07:55:12 -0500</pubDate>
        </item>
        <item>
            <title>Candlestick Sensor measures temperature and air velocity.</title>
            <link>http://news.thomasnet.com/fullstory/471192</link>
            <description>
Designed to characterize thermal conditions in electronic systems, Model MS 1000-CS-WC provides temperature measurements from -30 to +150&amp;#176;C, &amp;#177;1&amp;#176;C and velocity measurements from 0-51 m/s, &amp;#177;2%. Unit features 9.5 mm diameter base and comes in heights of 9, 12, and 20 mm. Narrow, low-profile design minimizes disturbance of heat flow in test domain, while plastic-sleeved stem facilitates installation and repositioning during testing process.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/velocimeters-91581009-1.html' target='_blank''&gt;Velocimeters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/velocity-sensors-95917258-1.html' target='_blank''&gt;Velocity Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-sensors-73754103-1.html' target='_blank''&gt;Temperature Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 09 Dec 2005 07:08:26 -0500</pubDate>
        </item>
        <item>
            <title>Board provides air flow and temperature measurement.</title>
            <link>http://news.thomasnet.com/fullstory/470042</link>
            <description>
Compact ISD-232(TM) board directly and simultaneously assesses air flow from 0-50 m/sec and temperatures from -30 to +150&amp;#176;C in computer feedback control and measurement systems using independent, mobile sensors that can be placed anywhere in test domain. Measuring 3.34 x 1.44 x 0.55 inch, board may be used to control devices such as laboratory wind tunnels and HVAC regulators or to provide read-out data for display systems. LabVIEW(TM) software is available.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/computer-hardware-peripherals' target='_blank''&gt;Computer Hardware and Peripherals&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/fluid-gas-flow-equipment' target='_blank''&gt;Fluid and Gas Flow Equipment&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3243&amp;prid=470042&amp;cat=954&amp;goto=http%3A%2F%2Fwww.snap-titequickdisconnects.com'&gt;SNAP-TITE INC. Quick Disconnect and Valve Div. - Untitled&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-measurement-equipment-84159607-1.html' target='_blank''&gt;Temperature Measurement Equipment&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/data-acquisition-boards-5902358-1.html' target='_blank''&gt;Data Acquisition Boards&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/computer-boards-5900451-1.html' target='_blank''&gt;Computer Boards&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-measurement-systems-761940-1.html' target='_blank''&gt;Air Flow Measurement Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 18 Nov 2005 07:15:36 -0500</pubDate>
        </item>
        <item>
            <title>Air Flow Monitors are suited for dirty air streams.</title>
            <link>http://news.thomasnet.com/fullstory/462809</link>
            <description>With no orifices or thermal elements to clog, AF 100 Series measures air flow/velocity in high-particulate processes and stacks. Abrasion-proof probes are available for pipes and ducts, while non-intrusive ring sensors are available for tubing. Combining time-of-flight/cross correlation principle with charge induction and current measurement techniques, monitors are suited for process pipes, injection lines, dryers, cyclones, precipitators, and baghouses.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-measuring-probes-95982047-1.html' target='_blank''&gt;Air Flow Measuring Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 01 Jun 2005 00:00:00 -0500</pubDate>
        </item>
        <item>
            <title>Compressed Air Sensor monitors air consumption.</title>
            <link>http://news.thomasnet.com/fullstory/461844</link>
            <description>
Used to continuously monitor compressed air systems, efector Metris divides plant into zones based on number of fittings and potential leakage points in any area. Sensor can be mounted in supply pipe to monitor one machine or in plant zone to monitor several machines, sensing compressed air levels when equipment is on or off. Micro DC, PNP sensor models SD6001 and SD8001 have respective measuring ranges of 0-44 and 0-132 scfm.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/fluid-gas-flow-equipment' target='_blank''&gt;Fluid and Gas Flow Equipment&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3243&amp;prid=461844&amp;cat=954&amp;goto=http%3A%2F%2Fwww.snap-titequickdisconnects.com'&gt;SNAP-TITE INC. Quick Disconnect and Valve Div. - Untitled&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/leak-sensors-73746703-1.html' target='_blank''&gt;Leak Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/compressed-air-management-systems-17091281-1.html' target='_blank''&gt;Compressed Air Management Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 04 Apr 2005 07:44:53 -0500</pubDate>
        </item>
        <item>
            <title>Airflow Sensor provides digital TTL output.</title>
            <link>http://news.thomasnet.com/fullstory/459086</link>
            <description>Utilizing thermistor technology, AccuSense F900 measures airflow temperature and velocity from 30&amp;#226;¤&amp;quot;200 fpm to 30&amp;#226;¤&amp;quot;2,000 fpm, depending on calibration. Product, resistant to mechanical shock and vibration, is available with temperature compensation settings of &amp;#177;5% of reading from 10&amp;#226;¤&amp;quot;35&amp;#176;C and &amp;#177;10% of reading from 10&amp;#226;¤&amp;quot;60&amp;#176;C. With supply voltage of 7&amp;#226;¤&amp;quot;13 Vdc, series has linear 0&amp;#226;¤&amp;quot;4 V output or digital output for direct control of airflow environment.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 12 Jan 2005 08:03:43 -0500</pubDate>
        </item>
        <item>
            <title>Air Flow Sensor provides pressure mapping.</title>
            <link>http://news.thomasnet.com/fullstory/27693</link>
            <description>
Tactilus Surface Air Flow Sensor contains 1-dimensional array of 16 pressure sensing elements. Capacitance-based design provides sensitivity for positive and negative pressures. Multiple strips can be connected to same interface to allow hundreds of data points to be collected. Model TAF-1000 is suited for measurement on flat surfaces, while Model TAF-2000 is flexible for curved surfaces. Model TAF-1500 is for rheology and fluid mechanics applications.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-sensors-73751604-1.html' target='_blank''&gt;Pressure Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-flow-sensors-73741365-1.html' target='_blank''&gt;Air Flow Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 31 Oct 2003 07:36:17 -0500</pubDate>
        </item>
        <item>
            <title>Gauge helps meet NOx emissions regulations.</title>
            <link>http://news.thomasnet.com/fullstory/18274</link>
            <description>Model 130-PC indicates flow of ammonia-air mixture in selective catalytic reduction systems. It also monitors ammonia filter prior to injection into vaporizer. Applications include simple cycle gas turbine facilities, combined gas turbine/steam turbine facilities, and conventional fossil fuel fired plants. &lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-flow-gages-32130205-1.html' target='_blank''&gt;Air Flow Gages&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ammonia-monitors-52252608-1.html' target='_blank''&gt;Ammonia Monitors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 10 Jan 2003 07:43:23 -0500</pubDate>
        </item>