<?xml version="1.0" encoding="iso-8859-1"?>
<!-- generator="FeedCreator 1.7.1" -->
<rss version="2.0">
    <channel>
        <title>ThomasNet Industrial Newsroom - </title>
        <description>ThomasNet News is a service of ThomasNet.com</description>
        <link>http://news.thomasnet.com</link>
        <lastBuildDate>Mon, 09 Nov 2009 16:18:33 -0500</lastBuildDate>
        <generator>FeedCreator 1.7.1</generator>
        <image>
            <url>http://news.thomasnet.com/images/header/TN_News_footer.gif</url>
            <title>Powered by ThomasNet News</title>
            <link>http://news.thomasnet.com</link>
            <width>129</width>
            <height>38</height>
            <description>ThomasNet News is a service of ThomasNet.com</description>
        </image>
        <item>
            <title>USB Protocol Analyzer captures, displays, and decodes errors.</title>
            <link>http://news.thomasnet.com/fullstory/830520</link>
            <description>
FTS4USB, USB Protocol Analyzer allows users to test, debug, monitor data flow, develop, reverse-engineer, and implement USB protocols. It can simultaneously capture, display, decode, filter, and detect errors. Software interface includes features such as smart-filtering, single-click export, and multiple decoded views.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/software' target='_blank''&gt;Software&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/protocol-analyzers-1661206-1.html' target='_blank''&gt;Protocol Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/bus-analyzers-1644608-1.html' target='_blank''&gt;Bus Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 09 Nov 2009 08:39:43 -0500</pubDate>
        </item>
        <item>
            <title>Machinery Squaring Plane facilitates precise equipment alignment.</title>
            <link>http://news.thomasnet.com/fullstory/568314</link>
            <description>
Coupled with Laser Microgage system, 90-Line Square Plane facilitates accelerated equipment measurement and alignment. Placed into path of laser reference beam, it forms precise right angle laser reference beam. Nosepiece of 90-Line, and right angle laser beam projected from it, can be turned through 360&amp;#176; rotation to define flat reference plane. Together, products provide precise measurements accurate to 0.0001 in. and can be used over ranges to 180 ft.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/optics-photonics' target='_blank''&gt;Optics and Photonics&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/machinery-machining-tools' target='_blank''&gt;Machinery and Machining Tools&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/machinery-alignment-systems-45631900-1.html' target='_blank''&gt;Machinery Alignment Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/alignment-geometric-measuring-lasers-43280676-1.html' target='_blank''&gt;Alignment &amp; Geometric Measuring Lasers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/laser-alignment-systems-1121946-1.html' target='_blank''&gt;Laser Alignment Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/alignment-systems-1121938-1.html' target='_blank''&gt;Alignment Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 05 Nov 2009 08:43:45 -0500</pubDate>
        </item>
        <item>
            <title>Emission Measurement Tool helps meet changing regulations.</title>
            <link>http://news.thomasnet.com/fullstory/568037</link>
            <description>
Consisting of partial-flow dilution system that measures particulate pollution, Smart Sampler 478 offers global tool for certification of diesel engines. Dual-cabinet design can be split in 2 sections, permitting user to keep one section close to engine and another in remote location. CFR1065 compliant for steady state and transient tests, portable Smart Sampler 478 provides continuous monitoring of progress throughout test and notifies user of potential problems.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/transportation-industry-products' target='_blank''&gt;Transportation Industry Products&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2991&amp;prid=568037&amp;cat=3287&amp;goto=http%3A%2F%2Fwww.tet-terra.com'&gt;Terra Environmental Technologies, A Terra Industries Co. - Untitled&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/green-clean' target='_blank''&gt;Green &amp; Clean&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/vehicle-emissions-testing-equipment-91571604-1.html' target='_blank''&gt;Vehicle Emissions Testing Equipment&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/emissions-testers-95911392-1.html' target='_blank''&gt;Emissions Testers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/continuous-emissions-monitors-cem-52254604-1.html' target='_blank''&gt;Continuous Emissions Monitors (CEM)&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/portable-emissions-analyzers-1651199-1.html' target='_blank''&gt;Portable Emissions Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/emissions-analyzers-1651181-1.html' target='_blank''&gt;Emissions Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 04 Nov 2009 08:43:15 -0500</pubDate>
        </item>
        <item>
            <title>Portable Combustion Analyzer delivers diverse functionality.</title>
            <link>http://news.thomasnet.com/fullstory/568156</link>
            <description>
Featuring field-replaceable sensors, multifunctional BTU1100 measures O2, CO, and CO2; efficiency; and excess air. It incorporates manometer, thermometer (ambient and flue gas), and CO leak detector as well as built-in impact printer. Metal connections are unbreakable, and dual hose configuration enables simultaneous gas and draft measurement. Also, 0-8,000 CO sensor offers built-in NOx filtration to ensure accurate readings. Resolution for CO is 1 ppm.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/combustion-analyzers-1648401-1.html' target='_blank''&gt;Combustion Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 03 Nov 2009 08:38:34 -0500</pubDate>
        </item>
        <item>
            <title>Multilayer Access Tester covers DSn, PDH, and Ethernet.</title>
            <link>http://news.thomasnet.com/fullstory/567795</link>
            <description>
As handheld multi-service test solution, AXS-200/855 offers fully integrated dual E1/DS1, DS3, ISDN PRI, and Gigabit Ethernet test suite. Capabilities include dual DSn/PDH and ISDN PRI testing, including real-time insertion of voice traffic and one-time setup of tests to be simultaneously run across all ISDN channels, as well as turnkey Ethernet testing, including RFC 2544, multi-stream traffic generation and monitoring, BERT, and IP connectivity tools.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/computer-hardware-peripherals' target='_blank''&gt;Computer Hardware and Peripherals&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/communications-testers-84475003-1.html' target='_blank''&gt;Communications Testers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/network-analyzers-1660109-1.html' target='_blank''&gt;Network Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 29 Oct 2009 08:31:59 -0500</pubDate>
        </item>
        <item>
            <title>Peracetic Acid  Monitor is used in water disinfection systems.</title>
            <link>http://news.thomasnet.com/fullstory/567770</link>
            <description>
Used for online measurement of peracetic acid (PAA) residuals in disinfection systems, Q45/85 Peracetic Acid Monitor uses membrane-covered polarographic sensor that does not require addition of chemical reagents. It provides real-time measurement of low levels of PAA in solution. Available in flowcell or submersion configurations, device is offered in AC-powered analyzer, loop-powered transmitter, or battery-operated portable versions.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/water-quality-monitors-52271251-1.html' target='_blank''&gt;Water Quality Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/acid-analyzers-1642883-1.html' target='_blank''&gt;Acid Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 29 Oct 2009 08:31:55 -0500</pubDate>
        </item>
        <item>
            <title>Mixed Signal Oscilloscopes optimize debugging.</title>
            <link>http://news.thomasnet.com/fullstory/567621</link>
            <description>
Providing up to 20 channels of measurement capture, MSO70000 Series features analog bandwidth from 4-20 GHz and 80 ps digital timing resolution. Units provide record lengths up to 250 million points and sample rates of 50 GS/s analog and 12.5 GS/s digital. With iCapture feature, instruments deliver analog views on any connected digital channel, enabling optimal debugging insight across all 20 channels for verification of DDR memory, ASICs, FPGAs, SoC devices, and digital RF.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/oscilloscopes-55161202-1.html' target='_blank''&gt;Oscilloscopes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 27 Oct 2009 08:37:56 -0500</pubDate>
        </item>
        <item>
            <title>Spectrum Analyzer extends analysis up to 20 GHz.</title>
            <link>http://news.thomasnet.com/fullstory/567624</link>
            <description>
When developing and characterizing radar and electronic warfare systems that operate in X and Ku bands, designers can use Model RSA6120A to set up automated measurements that allow them to understand behavior of transmit waveforms, validate transmitter's design, and debug problems in radar receiver. At Ku-band frequencies, unit features spurious-free dynamic range of 75 dB and 3rd order intercept of +19 dBm above 6 GHz. Flatness across 100 MHz is specified at &amp;#177;0.7 dB rms and &amp;#177;1.5&amp;#176; rms.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/optics-photonics' target='_blank''&gt;Optics and Photonics&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/signal-analyzers-1662204-1.html' target='_blank''&gt;Signal Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/spectrum-analyzers-1662600-1.html' target='_blank''&gt;Spectrum Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 27 Oct 2009 08:37:56 -0500</pubDate>
        </item>
        <item>
            <title>Oscilloscopes feature memory of 6.25 M points/channel.</title>
            <link>http://news.thomasnet.com/fullstory/567611</link>
            <description>
Providing 4 channels, DLM6000 Series includes 2 mixed-signal models with 16- or 32-bit logic capability and bandwidths of 500 MHz and 1 GHz, while DL6000 Series includes 3 digital models with bandwidths of 500 MHz, 1 GHz, and 1.5 GHz. All oscilloscopes have max sampling rate of 5 GS/sec, except for 1.5 GHz DL6154, which has sampling rate of 10 GS/sec. Additional features include update rate of 2.5 million waveforms/sec and History Memory function for waveform observation and analysis.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/digital-storage-oscilloscopes-55161251-1.html' target='_blank''&gt;Digital Storage Oscilloscopes&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/oscilloscopes-55161202-1.html' target='_blank''&gt;Oscilloscopes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 26 Oct 2009 08:54:03 -0500</pubDate>
        </item>
        <item>
            <title>Residual Gas Analyzers feature web-enabled design.</title>
            <link>http://news.thomasnet.com/fullstory/567683</link>
            <description>
Featuring optimized electronics platform for data acquisition, Microvision 2 and e-Vision 2 offer stability for e-diagnostic, process monitoring, and general vacuum trouble-shooting applications. Ethernet connectivity enables users to access data from anywhere on TCP-IP network, providing solution to wide-scale multi-RGA installations. RGAs are available with variety of software control systems, including built-in web application, recipe-driven Process Eye Professional, and TOOLweb RGA.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/residual-analyzers-1661909-1.html' target='_blank''&gt;Residual Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-analyzers-1651801-1.html' target='_blank''&gt;Gas Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 23 Oct 2009 08:35:43 -0500</pubDate>
        </item>
        <item>
            <title>Particle Analyzer uses laser particle detection technology.</title>
            <link>http://news.thomasnet.com/fullstory/830089</link>
            <description>
Designed for cleanliness monitoring of lubricants and similar fluids, Icount PD on-line analyzer has minimum sample time of 3 sec and offers integration with existing plant via M16 test points. IP66 rated unit can be used at flow rates from 10-160 ml/min and line pressures from 2-420 bar. Output options include LAN, RS232, and CANBUS connectivity, 4-20 mA and 0-5 V analog outputs, and relay contacts that can switch 5 A at up to 24 Vdc.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/particulate-analyzers-1660836-1.html' target='_blank''&gt;Particulate Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/laser-detectors-22151559-1.html' target='_blank''&gt;Laser Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/particulate-detectors-22171805-1.html' target='_blank''&gt;Particulate Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 22 Oct 2009 08:41:20 -0500</pubDate>
        </item>
        <item>
            <title>Network Analyzer helps optimize DOCSIS 3.0 services.</title>
            <link>http://news.thomasnet.com/fullstory/567346</link>
            <description>
Combining sweep, triple play service, and cable modem analysis, CM2800 lets field technicians monitor and diagnose issues/impairments on upstream and downstream channels to ensure no critical voice, data, or video service disruptions occur. True non-interfering downstream sweep ensures network is operating at required levels and frequency responses, while 5-200 MHz upstream sweep lets one person test full frequency span of return lasers with one instrument.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/computer-hardware-peripherals' target='_blank''&gt;Computer Hardware and Peripherals&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/network-analyzers-1660109-1.html' target='_blank''&gt;Network Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 20 Oct 2009 08:41:15 -0500</pubDate>
        </item>
        <item>
            <title>Protocol Analyzer facilitates PCIe testing and debugging.</title>
            <link>http://news.thomasnet.com/fullstory/567312</link>
            <description>
PCIe 2.0 E2960B Series is available with Zero Insertion Force (ZIF) flying leads probe, which lets designers use same probe points for physical layer measurements as well as protocol debugging. Supporting 2.5 and 5.0 GT/s PCIe data rates as well as capacitive loading rate, probe promotes insight into root cause without influencing monitored signals. Lead and probe lengths promote access to probing points on system under test.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/software' target='_blank''&gt;Software&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/signal-analyzers-1662204-1.html' target='_blank''&gt;Signal Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/protocol-analyzers-1661206-1.html' target='_blank''&gt;Protocol Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 20 Oct 2009 08:41:07 -0500</pubDate>
        </item>
        <item>
            <title>High-Voltage Differential Probes offer 10:1 attenuation.</title>
            <link>http://news.thomasnet.com/fullstory/830055</link>
            <description>
With ability to provide general-purpose differential signal measurements, Agilent N2792A and N2793A differential probes have input resistance of 1 M&amp;lt;font face='Symbol'&amp;gt;W&amp;lt;/font&amp;gt; (for N2792A) and 200 k&amp;lt;font face='Symbol'&amp;gt;W&amp;lt;/font&amp;gt; (for N2793A) and low input capacitance of 3.5 pF (for N2792A) and 1 pF (for N2793A) to minimize circuit loading. It can be powered by USB port on scope or computer, or 9 V internal battery. They are compatible with any oscilloscope with 50 &amp;lt;font face='Symbol'&amp;gt;W&amp;lt;/font&amp;gt; BNC input.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/differential-analyzers-1650407-1.html' target='_blank''&gt;Differential Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/probes-63550404-1.html' target='_blank''&gt;Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 16 Oct 2009 08:40:40 -0500</pubDate>
        </item>
        <item>
            <title>Signal Analyzers offer frequency coverage up to 7.5 GHz.</title>
            <link>http://news.thomasnet.com/fullstory/829978</link>
            <description>
Designed for RF measurements, N9000A CXA signal analyzers perform remote sweep-and-transfer in less than 6 msec via LAN. Library of measurement applications includes preconfigured test routines for noise figure, phase noise, and analog demodulation. Other features included are &amp;#177;0.5 dB absolute amplitude accuracy, +13 dBm third-order intermodulation, 161 dBm DANL, and 66 dB W-CDMA ACLR dynamic range.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/signal-analyzers-1662204-1.html' target='_blank''&gt;Signal Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 16 Oct 2009 08:40:38 -0500</pubDate>
        </item>
        <item>
            <title>Signal Analyzer suits RF and microwave applications.</title>
            <link>http://news.thomasnet.com/fullstory/829979</link>
            <description>
With up to 75 dB spurious-free dynamic range at 140 MHz analysis bandwidth, N9030A PXA signal analyzer provides frequency coverage up to 26.5 GHz. Specifications include 128 dBc/Hz phase noise at 10 kHz offset, 0.19 dB absolute amplitude accuracy, and sensitivity of -172 dBm DANL at 2 GHz (with preamplifier and Noise Floor Extension technology). Agilent 89600 vector signal analysis software can run inside instrument, providing advanced analysis of more than 70 demodulation formats.

&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/signal-analyzers-1662204-1.html' target='_blank''&gt;Signal Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 16 Oct 2009 08:40:38 -0500</pubDate>
        </item>
        <item>
            <title>Vector Network Analyzers offer modular hardware option.</title>
            <link>http://news.thomasnet.com/fullstory/567210</link>
            <description>
Used with ZVA Series vector network analyzers, ZVAX24 hardware extension facilitates intermodulation and pulse profile measurements. Depending on application, hardware can be equipped with combiners, harmonic filters, pulse modulators, and high power couplers. ZVAX24 is placed under vector network analyzer and RF ports are connected via semi-rigid coaxial cables. Control is performed via USB directly from analyzer, which displays dialog box containing block diagram of extension unit.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/computer-hardware-peripherals' target='_blank''&gt;Computer Hardware and Peripherals&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/network-analyzers-1660109-1.html' target='_blank''&gt;Network Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 16 Oct 2009 08:40:29 -0500</pubDate>
        </item>
        <item>
            <title>Spectrum Analyzers feature 30 MHz digital demodulator.</title>
            <link>http://news.thomasnet.com/fullstory/567100</link>
            <description>
With frequency coverage from 3 Hz to 26.5 GHz and general vector demodulation, 3280A Series allows engineers to analyze transmitter characteristics of wireless devices. Units offer accuracy of &amp;#177;0.15 dB up to 3 GHz, local oscillator phase noise of less than -115 dBm/Hz, offset of 1 GHz/10 kHz, and +18 dBm third order intermodulation. Windows&amp;#174; XP OS, internal hard drive, and built-in CD-ROM allow for wide range of interfaces, including LAN, USB, RS-232, IEEE 488, and VGA outputs.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/optics-photonics' target='_blank''&gt;Optics and Photonics&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/spectrum-analyzers-1662600-1.html' target='_blank''&gt;Spectrum Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 15 Oct 2009 08:34:30 -0500</pubDate>
        </item>
        <item>
            <title>Digital Signature Software targets individuals/small offices.</title>
            <link>http://news.thomasnet.com/fullstory/829889</link>
            <description>
Offering software and free digital certificate, desktop-based CoSign&amp;#174; Desktop allows users to digitally sign and seal Adobe&amp;#174; PDF, Microsoft&amp;#174; Office, and other document formats. Software removes need to upload files to third-party website or even be connected to internet for signing, keeping confidential agreements confidential. Signs are created permanently on document, allowing verification by anyone, anytime, anywhere, without need to download special verification software.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/software' target='_blank''&gt;Software&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/automatic-id' target='_blank''&gt;Automatic ID&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/data-security-software-17264250-1.html' target='_blank''&gt;Data Security Software&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/signature-verification-systems-75231357-1.html' target='_blank''&gt;Signature Verification Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 13 Oct 2009 08:32:19 -0500</pubDate>
        </item>
        <item>
            <title>Bluetooth Test Set conducts all audio measurements.</title>
            <link>http://news.thomasnet.com/fullstory/566976</link>
            <description>
As fully integrated solution, MT8855A measures audio performance of products using Bluetooth Advanced Audio Distribution Profile (A2DP), headset profile, and hands-free profile. It covers 20 Hz to 20 kHz range and establishes standard Bluetooth link with DUT to perform all key measurements - level, frequency response, and THD+N - via internal audio generators and analyzers. PC-based BlueAudio software, included, aids instrument setup and displays all results in Windows-style GUI.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/audio-analyzers-1643154-1.html' target='_blank''&gt;Audio Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 12 Oct 2009 08:39:40 -0500</pubDate>
        </item>
    </channel>
</rss>
