        <item>
            <title>Transmitter offers measurement ranges from 0.5-200 mWG.</title>
            <link>http://news.thomasnet.com/fullstory/830566</link>
            <description>
Designed for submersible applications, SDI-12L (serial data interface at 1,200 baud) hydrostatic level transmitter has operating temperature range of -20 to +60&amp;#176;C, and can be used in depths of up to 200 m. Accuracy of inbuilt temperature sensor is less than &amp;#177;0.1% of full-scale output. Models use either stainless steel silicon-based pressure sensor or ceramic pressure sensor in marine-bronze, and piezoresistive technology. Ceramic pressure versions suit seawater, estuary, and saline applications.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/liquid-level-transmitters-87430955-1.html' target='_blank''&gt;Liquid Level Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transmitters-87431409-1.html' target='_blank''&gt;Pressure Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 12 Nov 2009 08:32:48 -0500</pubDate>
        </item>
        <item>
            <title>Humidity &amp;amp; Temperature Transmitter offers high sensitivity.</title>
            <link>http://news.thomasnet.com/fullstory/568233</link>
            <description>
Suited for pharmaceutical and industrial applications, Model TH200 includes functions for relative and absolute humidity, dew point, wet and dry temperature, and enthalpy. Unit offers measuring ranges of 0-100% RH and -40 to +356&amp;#176;F with accuracy as tight as &amp;#177;1.5% RH and &amp;#177;0.3% Rdg &amp;#177;0.45&amp;#176;F with resolution of 0.1% RH and 0.1&amp;#176;F/&amp;#176;C. Enclosed in IP65 ABS housing with or without 2-line backlit display, it provides simultaneous display of 2 parameters and includes visual and audible alarms.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 04 Nov 2009 08:43:25 -0500</pubDate>
        </item>
        <item>
            <title>High Temperature/Pressure Transducers offer amplified output.</title>
            <link>http://news.thomasnet.com/fullstory/830337</link>
            <description>
Suited for extreme downhole oilfield applications and specifically designed for high cycle and high pressure applications requiring accuracy, stability, and long term performance, 212-40-010 Series pressure and temperature transducers are offered in pressure ranges from 0-5,000 to 0-30,000 psia and operate at temperatures from -40&amp;#176;F to +400&amp;#176;F. They can be provided with alternate pressure port fittings and electrical connections.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transducers-86980604-1.html' target='_blank''&gt;Temperature Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 03 Nov 2009 08:38:39 -0500</pubDate>
        </item>
        <item>
            <title>Pressure/Temperature Transducer is customizable.</title>
            <link>http://news.thomasnet.com/fullstory/830339</link>
            <description>
Designed for direct media stream immersion, 311-38-540 pressure and temperature combination series comes in pressure ranges from 0-5,000 to 0-30,000 psia, operates at temperatures from -40&amp;#176;F to +425&amp;#176;F and is available with Vdc output and accurate to 0.02% F.S. Product can be offered with alternate port fittings and electrical connections.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transducers-86980604-1.html' target='_blank''&gt;Temperature Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 03 Nov 2009 08:38:39 -0500</pubDate>
        </item>
        <item>
            <title>Digital Transducer measures pressure and temperature.</title>
            <link>http://news.thomasnet.com/fullstory/567812</link>
            <description>
Offering MPU-based pressure and temperature measurement, Digital True Pressure Series covers pressure ranges from 0-5,000 to 0-30,000 psia and temperatures from -40 to +302&amp;#176;F. All-welded Inconel&amp;#174; construction withstands corrosive environments, and temperature output is programmable in &amp;#176;K/&amp;#176;F/&amp;#176;C. Along with memory-based user access, features include RS-232, RS-485, I&amp;#178;C, or SPI interfaces as well as digital pressure and temperature output with end-user requests or programmed timing.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-meters-51082303-1.html' target='_blank''&gt;Temperature Meters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-meters-51070902-1.html' target='_blank''&gt;Pressure Meters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transducers-86980604-1.html' target='_blank''&gt;Temperature Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 29 Oct 2009 08:32:01 -0500</pubDate>
        </item>
        <item>
            <title>Flow Transmitters feature optional temperature output.</title>
            <link>http://news.thomasnet.com/fullstory/566780</link>
            <description>
Suited for measuring flow in most clean liquids and many liquids with entrained solids, CSLFC and CSLFB Ultrasonic Flow Transmitters are available with 3-wire RTD temperature output. RTD is built into transducer well, offering process temperature measurement and flow measurement in one instrument. Made of cast brass, CSLFB models are designed for full scale flow ranges from 15-400 gpm in &amp;#190;-3 in. pipe, while CSLFC units measure flows to 4,000 gpm in 4-10 in. pipe.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/flow-transmitters-87430856-1.html' target='_blank''&gt;Flow Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ultrasonic-transmitters-87441481-1.html' target='_blank''&gt;Ultrasonic Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 05 Oct 2009 08:27:04 -0500</pubDate>
        </item>
        <item>
            <title>Air Velocity Transmitter also measures temperature.</title>
            <link>http://news.thomasnet.com/fullstory/566627</link>
            <description>
Suited for HVAC applications, Series VTT Hot-Wire Transmitter offers field-selectable velocity and temperature ranges in English or metric units with maximums up to 6,000 fpm (30 m/s) and 212&amp;#176;F (100&amp;#176;C). Housed in ABS enclosure rated NEMA 4X, units are offered with or without 5-digit LCD display and are available in duct mount version or remote probe version with cable.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-velocity-transmitters-87420808-1.html' target='_blank''&gt;Air Velocity Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 01 Oct 2009 08:42:42 -0500</pubDate>
        </item>
        <item>
            <title>Humidity/Temperature Transmitter is weather-resistant.</title>
            <link>http://news.thomasnet.com/fullstory/564386</link>
            <description>
Supplied in NEMA 3S housing with sintered filter to protect sensor, Series WHT is available with 4-20 mA, 0-5 V, or 0-10 Vdc outputs for humidity and temperature. Passive RTD and thermistor outputs are available to monitor temperature. Able to recover fully from saturation, transmitter is designed to withstand elements and suited for measuring outside air temperature and humidity for building automation applications.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 06 Aug 2009 08:28:43 -0500</pubDate>
        </item>
        <item>
            <title>Humidity Sensor/Transmitter has probe design.</title>
            <link>http://news.thomasnet.com/fullstory/828776</link>
            <description>
Allowing for precise measurement of relative humidity in air from 0-100% RH, EE061 series is suited for use outside, in stables, storage rooms, or greenhouses. It operates from supply voltage of 9-28 Vdc, mrsdutrd 160 mm long, handles temperatures from -40 to 60&amp;#176;C, and comes with 0.5 or 3 m long fixed connection cable. Options include 4-wire passive (sink) temperature output, and mounting flange, and radiation shield for outdoor applications.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-sensors-73745853-1.html' target='_blank''&gt;Humidity Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 05 Aug 2009 08:28:22 -0500</pubDate>
        </item>
        <item>
            <title>Transmitter combines humidity and temperature sensing.</title>
            <link>http://news.thomasnet.com/fullstory/562541</link>
            <description>
Series RHP combines voltage or current humidity transmitter output with passive temperature thermistor or RTD output. Polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants, and humidity sensors are available with 2% or 3% accuracies. In addition to optional 2-line alphanumeric LCD, duct-mounted transmitters are available with interchangeable filter options and replaceable sensors.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-sensors-73754103-1.html' target='_blank''&gt;Temperature Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-sensors-73745853-1.html' target='_blank''&gt;Humidity Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 26 Jun 2009 08:28:09 -0500</pubDate>
        </item>
        <item>
            <title>Displacement Transducers operate in high radiation areas.</title>
            <link>http://news.thomasnet.com/fullstory/826721</link>
            <description>
PY non-contacting displacement transducers are designed to operate under high temperature and cryogenic conditions, as well as in environments where radiation is present. Transducers use variable reluctance principles in double coil configuration and work with any magnetic material. Measuring range is 1.5-6 mm and transducer is suitable for use in temperatures from -220 to +600&amp;#176;C and with radiation doses up to 100G Rad.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/noncontract-displacement-transducers-86941002-1.html' target='_blank''&gt;Non-Contract &amp; Displacement Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transducers-86980604-1.html' target='_blank''&gt;Temperature Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/variable-reluctance-pressure-transducers-86984002-1.html' target='_blank''&gt;Variable Reluctance Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 27 May 2009 08:37:52 -0500</pubDate>
        </item>
        <item>
            <title>Air Velocity/Air Flow Transmitter suits pharmaceutical use.</title>
            <link>http://news.thomasnet.com/fullstory/825758</link>
            <description>
Model CTV200 air velocity &amp;amp; air flow transmitter comes with measuring ranges between 0-200 fpm to 0-4,000 fpm and 32-122&amp;#176;F. Features included are 2 visual dual color LED and audible buzzer alarms, software or keypad configuration, and configurable intermediate and center zero ranges. Product has two output between 4-20 mA or 0-10 V (4 wires), RS 232, and 2 RCR relays 6 A/230 Vac.


&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-velocity-transmitters-87420808-1.html' target='_blank''&gt;Air Velocity Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/flow-transmitters-87430856-1.html' target='_blank''&gt;Flow Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 02 Apr 2009 08:40:32 -0500</pubDate>
        </item>
        <item>
            <title>Temperature Transmitter is WirelessHART(TM) network compatible.</title>
            <link>http://news.thomasnet.com/fullstory/825351</link>
            <description>
Suited for high density temperature measurement, Rosemount&amp;#174; 848T wireless temperature transmitter monitors up to 4 independently configurable RTD, thermocouple, ohm, millivolt, and 4-20 mA inputs, allowing for proactive maintenance of key assets. It includes Electronic Device Display user interface, which provides graphical screens to deliver important configuration and information. Self-powered unit utilizes SmartPower(TM) technology to provide intrinsically safe power module.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/communication-systems-equipment' target='_blank''&gt;Communication Systems and Equipment&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/smart-transmitters-87440434-1.html' target='_blank''&gt;Smart Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/wireless-transmitters-96009485-1.html' target='_blank''&gt;Wireless Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 17 Mar 2009 08:30:34 -0500</pubDate>
        </item>
        <item>
            <title>RTD Thermometers offer &amp;#177;0.3&amp;#176;F accuracy over 1 yr period.</title>
            <link>http://news.thomasnet.com/fullstory/555685</link>
            <description>
Available in standard and custom probe configurations, DST500 Temperature Indicator and DSX500 Transmitter Thermometers feature 1 in. high LCD display, readable from 30 ft away. Model DST500 includes field replaceable battery with 2-yr operational life, while DSX500 is loop-powered from integral, 4-20 mA transmitter. Factory configurable to user's specification, thermometers offer temperature range of -328 to 1,472&amp;#176;F and come with NIST Traceable Certificate of Calibration.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/resistance-thermometers-85180800-1.html' target='_blank''&gt;Resistance Thermometers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-indicators-40051807-1.html' target='_blank''&gt;Temperature Indicators&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/resistance-temperature-detectors-rtd-probes-63558944-1.html' target='_blank''&gt;Resistance Temperature Detectors (RTD) Probes&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/resistance-temperature-detectors-rtd-22181457-1.html' target='_blank''&gt;Resistance Temperature Detectors (RTD)&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 16 Feb 2009 09:09:43 -0500</pubDate>
        </item>
        <item>
            <title>Compact Transmitter measures moisture content in oil.</title>
            <link>http://news.thomasnet.com/fullstory/822769</link>
            <description>
Using monolithic humidity/temperature sensor element, series EE381 transmitter measures moisture content in oil in range of 0-1 aw at temperatures from -40 to 80&amp;#176;C. Sensing head is pressure tight up to 1,450 psi and can be mounted either with G&amp;#189; in. ISO or &amp;#189; in. NPT thread, while rugged, compact metal housing is rotatable over 360&amp;#176;.  Applications include monitoring of transformer oil, hydraulic oil, motor oil of ship engines and lubrication oil of bearings.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/moisture-content-instruments-40650855-1.html' target='_blank''&gt;Moisture Content Instruments&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 15 Dec 2008 07:25:10 -0500</pubDate>
        </item>
        <item>
            <title>Transmitter provides humidity/temperature sensing.</title>
            <link>http://news.thomasnet.com/fullstory/551527</link>
            <description>
Series RH-R Humidity/Temperature Transmitter is designed for applications where space is limited. Compact sensor is protected by replaceable filter and can be mounted up to 16 ft away from weatherproof base. With relative humidity range of 0-100% and temperature range of -40 to 140&amp;#176;F, Series RH-R is suited for environmental chambers, rubber bladder burst detection systems, and air handler applications.

&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 31 Oct 2008 07:43:16 -0500</pubDate>
        </item>
        <item>
            <title>Transmitter measures moisture in liquid hydrocarbons.</title>
            <link>http://news.thomasnet.com/fullstory/821233</link>
            <description>
Vaisala HUMICAP&amp;#174; moisture and temperature transmitter for Oil MMT162, measures moisture in oil in terms of water activity and temperature. Measurements are independent of oil type, age, and temperature. Model MMT162 has 2 analog outputs that can be scaled and measurement ranges changed. Featuring RS-485 serial output, and optional LED-cable for enabling visual alarm, unit suits applications in lubrication systems, hydraulic systems, and transformers.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/moisture-detectors-22171201-1.html' target='_blank''&gt;Moisture Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/dew-point-transmitters-87422507-1.html' target='_blank''&gt;Dew Point Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-transmitters-87430898-1.html' target='_blank''&gt;Humidity Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 16 Oct 2008 07:54:37 -0500</pubDate>
        </item>
        <item>
            <title>Temperature Transmitters feature solid-state design.</title>
            <link>http://news.thomasnet.com/fullstory/549243</link>
            <description>
Featuring 316L stainless steel housing with IP67 enclosure rating, 837E Non-Display Temperature Transmitters are PC-programmable with 4-20 mA analog output. Microprocessor-based devices have no moving parts and can measure media temperatures from -58 to 302&amp;#176;F. Available with sanitary connections, transmitters are suited for use in food, beverage, and pharmaceutical industries, as well as automotive, machine tool, hydraulics, and batch temperature control applications. 
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/programmable-transmitters-87432407-1.html' target='_blank''&gt;Programmable Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 18 Sep 2008 07:40:13 -0500</pubDate>
        </item>
        <item>
            <title>Temperature Transmitter has universal input options.</title>
            <link>http://news.thomasnet.com/fullstory/820674</link>
            <description>
Concentrating up to 32 signals onto single twisted wire pair, TCS Temperature Concentrator System can be set to accept RTD (2-, 3-, 4-wire, Pt, Cu, Ni), thermocouple (J, K, E, T, R, S, N, B, C), resistance/potentiometer (0-4,000 ohms), and -50 to 1,000 mV inputs. It utilizes HART, or MODBUS RTU with converter module, for communication from field to control room. Measuring less than 5 in. wide, loop-powered TCS's operating parameters can be configured from any HART-based system.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 16 Sep 2008 07:45:37 -0500</pubDate>
        </item>
        <item>
            <title>RTD Probe Assemblies handle temperatures from -60 to 500&amp;#176;F.</title>
            <link>http://news.thomasnet.com/fullstory/819770</link>
            <description>
Available in .187 and .250 in. dia and in lengths up to 12 in., RTD probe assemblies and temperature transmitters include thin film PT100 platinum RTD sensing element packaged in all welded 316L stainless steel probe. Options include programmable transmitter built into the probe assembly as well as probe configurations featuring Tri-Clover&amp;#174; fittings and surface finishes that comply with 3A Standard 74-03 for food, dairy, beverage, pharmaceutical, and chemical processing applications. 
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-probes-63559702-1.html' target='_blank''&gt;Temperature Probes&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/programmable-transmitters-87432407-1.html' target='_blank''&gt;Programmable Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-transmitters-87441200-1.html' target='_blank''&gt;Temperature Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/resistance-temperature-detectors-rtd-probes-63558944-1.html' target='_blank''&gt;Resistance Temperature Detectors (RTD) Probes&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 25 Aug 2008 07:39:36 -0500</pubDate>
        </item>