            <title>Piezoresistive Transducers have output voltage up to 300 mV.</title>
            <link>http://news.thomasnet.com/fullstory/829872</link>
            <description>
Available in ranges from 15-500 psia, 8540 series miniature high sensitivity piezoresistive absolute pressure transducers measure static or dynamic pressure within variety of high temperature applications. Units feature 0.15 in. face dia for flush mounting for skin pressure measurements on aircraft, or inlet distortion pressures in turbine engines. Internal sensitivity compensation and zero trim provide accuracy to +500&amp;#176;F with diminished lifetime operations in temperatures up to +600&amp;#176;F.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/absolute-pressure-transducers-86936002-1.html' target='_blank''&gt;Absolute Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/piezoelectric-transducers-86970209-1.html' target='_blank''&gt;Piezoelectric Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 06 Oct 2009 08:37:04 -0500</pubDate>
        </item>
        <item>
            <title>Linear Cable Transducer offers simple, adaptable installation.</title>
            <link>http://news.thomasnet.com/fullstory/827402</link>
            <description>
Model LT25 cable transducer utilizes flexible measuring cable mounted to internal spring-loaded spool and quadrature encoder output to precisely measure linear motion applications. Sturdy cable is made of nylon coated stainless steel and has measurement range up to 125 in. Mounting bracket and encoder connector position are easily reoriented for added adaptability. With an IP66 rating, LT25 suits variety of industrial measurement challenges.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cable-extension-transducers-86940459-1.html' target='_blank''&gt;Cable Extension Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/hazardous-location-transducers-86959400-1.html' target='_blank''&gt;Hazardous Location Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/linear-transducers-86960804-1.html' target='_blank''&gt;Linear Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 16 Jun 2009 08:29:09 -0500</pubDate>
        </item>
        <item>
            <title>Torque Transducer has 100-200 Nm measurement range.</title>
            <link>http://news.thomasnet.com/fullstory/827227</link>
            <description>
Suited for engine, gear or chassis test benches in automotive industry, T12 series of digital torque transducers have accuracy class of 0.03 over measuring frequency range of 0 Hz to 6 kHz. Measurement data are available via either voltage or frequency output or via fieldbuses CAN-open and Profibus DP with up to 4,800 measured values per second output. T12 dialog facilitates secure, error-free data transmission between rotor and stator, even under difficult ambient conditions.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/digital-transducers-95989620-1.html' target='_blank''&gt;Digital Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/torque-transducers-86981008-1.html' target='_blank''&gt;Torque Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 09 Jun 2009 08:25:15 -0500</pubDate>
        </item>
        <item>
            <title>Digital Pressure Transducer is designed for CANBus systems.</title>
            <link>http://news.thomasnet.com/fullstory/826690</link>
            <description>
With standard pressure range up to 15,000 psis, 220-38 Digital Series transducers suit high cycle and high pressure applications in sub-sea, industrial, automation, military and automotive environments. Integrating CANBus serial communications interface, all-welded, hermetically sealed unit uses standard CANopen protocol. Other features included are internal linearity and temperature correction, self test, state of health status, outputs in psi, Bar and Pascal.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/custom-transducers-95996575-1.html' target='_blank''&gt;Custom Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/digital-transducers-95989620-1.html' target='_blank''&gt;Digital Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/strain-gage-transducers-86980554-1.html' target='_blank''&gt;Strain Gage Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 22 May 2009 08:26:51 -0500</pubDate>
        </item>
        <item>
            <title>Transducers measure pressures from atmospheric to 10-8 Torr.</title>
            <link>http://news.thomasnet.com/fullstory/826588</link>
            <description>
Able to be mounted in any orientation, Series 970 Cold Cathode Transducers use up to 4 sensors, including cold cathode, MicroPirani(TM), and Piezo technologies. Providing functionality over wide measurement range, it eliminates need for multiple gauges. They include both analog and digital communication and can be used with PDR900 controller. Three independent relay set points provide process control and set point values, hysteresis, and direction are user-configurable.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cold-cathode-gages-96183041-1.html' target='_blank''&gt;Cold Cathode Gages&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gauging-transducers-86959202-1.html' target='_blank''&gt;Gauging Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 08 May 2009 09:08:23 -0500</pubDate>
        </item>
        <item>
            <title>Current Transducers meet military/industrial specifications.</title>
            <link>http://news.thomasnet.com/fullstory/558361</link>
            <description>
With supply voltage of +22 to +32 Vdc, military-grade, bi-directional Series S651 provides output of 0 to &amp;#177;5 V with accuracy of 1% full scale. Current ranges are 0 to &amp;#177;100 A to 0 to &amp;#177;200 A. Operating from -40 to +65&amp;#176;C, devices feature frequency range of DC-3.5 kHz and 100 &amp;#181;sec response time. Industrial grade, bi-directional Series S764 offers current ranges from 0 to &amp;#177;20 A to 0 to &amp;#177;100 A.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=558361&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electronic-components-devices' target='_blank''&gt;Electronic Components and Devices&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/transducers-86931003-1.html' target='_blank''&gt;Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/sensors-73740607-1.html' target='_blank''&gt;Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/current-sense-transformers-87050506-1.html' target='_blank''&gt;Current Sense Transformers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/current-voltage-power-transducers-86940509-1.html' target='_blank''&gt;Current, Voltage, Power Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/hall-effect-sensors-73745101-1.html' target='_blank''&gt;Hall Effect Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/current-sensors-73742116-1.html' target='_blank''&gt;Current Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/current-voltage-power-measurement-instruments-96127287-1.html' target='_blank''&gt;Current, Voltage &amp; Power Measurement Instruments&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 01 Apr 2009 08:34:40 -0500</pubDate>
        </item>
        <item>
            <title>Cable-Extension Transducer delivers 4-20 mA signal output.</title>
            <link>http://news.thomasnet.com/fullstory/825438</link>
            <description>
Built for wet environments and outdoor applications, rugged SR1M provides position feedback signal that is directly proportional to length of its spring-loaded, 125 in. measuring cable. It offers programmable stroke range settings from 25-125 in. with input voltage of 10-30 Vdc, and maximum velocity of 80 ips with maximum acceleration of 10 G. Loop powered unit weighs only 2.5 lb, includes internal dip switch for signal reversing, and is offered with optional cordset.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cable-extension-transducers-86940459-1.html' target='_blank''&gt;Cable Extension Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/position-transducers-86970340-1.html' target='_blank''&gt;Position Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/position-sensors-73751109-1.html' target='_blank''&gt;Position Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 17 Mar 2009 08:30:35 -0500</pubDate>
        </item>
        <item>
            <title>Module facilitates PC access to live ultrasonic sensor data.</title>
            <link>http://news.thomasnet.com/fullstory/556112</link>
            <description>
Connected to PC, X1 Ranging Module Pro(TM) lets users view critical sensor parameters for instruction, analysis, alignment, and gain calibration. It combines all standard functions of ultrasonic ranging module as well as multi-channel, USB-based oscilloscope feature. Analog output is 0-5 Vdc, with pushbutton Min and Max range setting of 6 in. to 20 ft. Along with X1 module, developers kit includes electrostatic ultrasonic transducer (with housing), power supply, USB cable, and software.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ultrasonic-transducers-86981206-1.html' target='_blank''&gt;Ultrasonic Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ultrasonic-analyzers-1670405-1.html' target='_blank''&gt;Ultrasonic Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 19 Feb 2009 08:34:07 -0500</pubDate>
        </item>
        <item>
            <title>I/P Transducer is vibration and position insensitive.</title>
            <link>http://news.thomasnet.com/fullstory/823315</link>
            <description>
Type-595XP current-to-pressure transducer holds FM and CSA approvals as intrinsically safe and explosionproof and is also compliant with ATEX directive 94/9/EC. Able to be  mounted in any position and stable in high vibration environments, specifications include &amp;#188; in. pneumatic and &amp;#189; in. electric NPT porting; 4-20 mA input; 3-15, 3-27, 6-30 psig output; and max supply pressure of 22 psi (3-15 output) and 42 psi (other outputs). Flow capacity is 2.4 scfm and air consumption is 0.1 scfm.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/hazardous-location-transducers-86959400-1.html' target='_blank''&gt;Hazardous Location Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/currenttopressure-i-p-voltagetopressure-e-p-transducers-96004957-1.html' target='_blank''&gt;Current-To-Pressure (I/P) , Voltage-To-Pressure (E/P) Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 07 Jan 2009 08:44:41 -0500</pubDate>
        </item>
        <item>
            <title>Transducer features overload capacity up to 1,000 A.</title>
            <link>http://news.thomasnet.com/fullstory/823008</link>
            <description>
Based on low consumption Fluxgate Technology, Series DCT-200A measures DC, AC currents, with precision levels of 99.9% of linearity and 5 ppm of linear error. It offers wide band-width of up to 100 kHz, up to 200 A, and measures 52 x 52 x 37 mm. Featuring immunity to all kind of interferences, unit suits energy measurement systems, medical equipment, high stability inverters, and high power supply applications.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=823008&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/electrical-transducers-6289-1.html' target='_blank''&gt;Electrical Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/power-transducers-6292-1.html' target='_blank''&gt;Power Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/current-voltage-power-transducers-86940509-1.html' target='_blank''&gt;Current, Voltage, Power Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/transducers-86931003-1.html' target='_blank''&gt;Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 05 Jan 2009 08:37:38 -0500</pubDate>
        </item>
        <item>
            <title>Digital Pressure Transducer is LabVIEW&amp;#174; compatible.</title>
            <link>http://news.thomasnet.com/fullstory/821024</link>
            <description>
Available with LabVIEW(TM) driver and LabVIEW(TM) based utility software, Heise&amp;#174; DXD digital pressure transducer allows user to address, configure and monitor one or more DXDs. It is offered in ranges from vacuum through 7,500 psi and features accuracy of &amp;#177;0.02% of full span, which includes effects of temperature. With update rates of up to 15 msec, dozens of DXDs can communicate with single PC serial port at speeds up to 115 Kbps via full-duplex RS232 or RS485 communication protocol.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/digital-transducers-95989620-1.html' target='_blank''&gt;Digital Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 02 Oct 2008 07:33:35 -0500</pubDate>
        </item>
        <item>
            <title>Digital Pressure Transducer supports LabVIEW(TM).</title>
            <link>http://news.thomasnet.com/fullstory/549955</link>
            <description>
Available with LabVIEW(TM) driver and LabVIEW(TM)-based utility software, Model DXD offers ranges from vacuum through 7,500 psi with accuracy of &amp;#177;0.02% of full span, which includes effects of temperature. Wetted materials and enclosure are 300 series stainless steel to stand up to variety of process media and environments. With update rates to 15 msec, dozens of DXDs can communicate with single PC serial port at speeds up to 115 Kbps via full-duplex RS232 or RS485 communication protocol.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/digital-transducers-95989620-1.html' target='_blank''&gt;Digital Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 26 Sep 2008 07:39:50 -0500</pubDate>
        </item>
        <item>
            <title>Marine Pressure Transducers offer 0.25% accuracy.</title>
            <link>http://news.thomasnet.com/fullstory/545770</link>
            <description>
Available in gage or absolute pressure ranges of 50 in. H&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;O to 5,000 psi, Series 5SE01313 features thick film design with all stainless steel construction for durability in extreme applications. Units come with internal shunt resistor for system function verification. Powered by 28 Vdc, transducers have vibration limit of 0.04% RO/G and deliver 0-5 V isolated output.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/marine-transducers-86970076-1.html' target='_blank''&gt;Marine Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 18 Jun 2008 07:47:12 -0500</pubDate>
        </item>
        <item>
            <title>Marine Pressure Transducer meets military standards.</title>
            <link>http://news.thomasnet.com/fullstory/545229</link>
            <description>
Designed to meet requirements of military standard MIL-T-24742(SH), Model PX2471 is available in pressure ranges from 15-10,000 psi with loop-powered, 4-20 mA output signal. Unit utilizes Sputtered Thin Film Technology and requires minimal maintenance with non-interacting zero and span adjustments. Calibration test points are accessible for function verification. Applications include naval shipboard use, surface and sub-surface vessels, as well as general maritime uses.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/marine-transducers-86970076-1.html' target='_blank''&gt;Marine Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 11 Jun 2008 07:21:57 -0500</pubDate>
        </item>
        <item>
            <title>Current Transducers monitor automotive batteries.</title>
            <link>http://news.thomasnet.com/fullstory/817315</link>
            <description>
Designed to measure dc, ac, or pulsed current from &amp;#177;40 to &amp;#177;100 A, HAB 60-S transducers provide PWM output signal proportional to primary current being measured and operate from unipolar 5 V supply. They use open-loop, Hall-effect technology that helps simplify installation and servicing by eliminating need to cut primary cable carrying measured current. Electric offset error is 0.075 A across temperature range from -10 to +65&amp;#176; C and 0.15 A across full range from -40 to +125&amp;#176;C.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=3064&amp;prid=817315&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/automotive-transducers-86940400-1.html' target='_blank''&gt;Automotive Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/current-voltage-power-transducers-86940509-1.html' target='_blank''&gt;Current, Voltage, Power Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 02 Jun 2008 07:43:34 -0500</pubDate>
        </item>
        <item>
            <title>Transducers suit industrial and hazardous applications.</title>
            <link>http://news.thomasnet.com/fullstory/817163</link>
            <description>
PT-400 Amplified Output Pressure Transducers provide minimum of 10 million operating cycles with accuracy of &amp;#177;0.25% F.S. (B.F.S.L.), in operating temperatures from -40 to 180&amp;#176;F. They are cCSAus certified for use in hazardous locations, weigh 10 oz, and offer standard 4-20 mA, 0-5 Vdc, and 0-10 Vdc outputs. Units feature pressures ranging from 0-20,000 psi, along with high burst pressure to 3x full scale and overpressure to 2x full scale for in-process reliability.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/hazardous-location-transducers-86959400-1.html' target='_blank''&gt;Hazardous Location Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transmitters-87431409-1.html' target='_blank''&gt;Pressure Transmitters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 28 May 2008 07:48:40 -0500</pubDate>
        </item>
        <item>
            <title>Pressure Transducers feature sputtered strain gauge design.</title>
            <link>http://news.thomasnet.com/fullstory/816967</link>
            <description>
With amplifier/regulator accuracy of 0.25%, 6SE01079 Series of Marine Pressure Transducers conform to Mil-I-45208A quality requirements. Stainless steel constructed products have vibration limit of 0.04% RO/G, isolated 0-5 Vdc output, and are 28 Vdc powered. They are available in gage or absolute pressure, ranges of 50 in. H20 to 5,000 psi, and come with internal shunt resistor to simulate transducer output.


&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/marine-transducers-86970076-1.html' target='_blank''&gt;Marine Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 19 May 2008 07:38:53 -0500</pubDate>
        </item>
        <item>
            <title>Sputtered Thin Film Transducer has accuracy of 0.25%.</title>
            <link>http://news.thomasnet.com/fullstory/816817</link>
            <description>
Series PX1000 provides stability of &amp;#177;0.1% FSO for minimum of 24 hr when subjected to any combination of constant temperature and pressure within specified limits. Standard ranges are 15-10,000 psi for absolute and gage models, and for sealed gage models ranges are available at 100 psi and above. Featuring all-welded construction with strain isolation snf stable sensor elements, units are suited for automotive testing and chemical industries.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/pressure-transducers-86970605-1.html' target='_blank''&gt;Pressure Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gauging-transducers-86959202-1.html' target='_blank''&gt;Gauging Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/absolute-pressure-transducers-86936002-1.html' target='_blank''&gt;Absolute Pressure Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 09 May 2008 07:33:38 -0500</pubDate>
        </item>
        <item>
            <title>Cable-Extension Transducer fits into tiny spaces.</title>
            <link>http://news.thomasnet.com/fullstory/541908</link>
            <description>
Suited for position sensing in applications such as robotics, crash test dummies, biomedical applications, and automotive testing, M150 has .74 x .74 x .38 in. aluminum body, operates over 1.5 in. range, and does not require precise manual alignment. Its .014 in. dia, nylon-coated, stainless steel measuring cable - attached to object under motion - offers constant tension and is fully retractable. Conducive, plastic potentiometer provides high-linearity voltage feedback signal.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cable-extension-transducers-86940459-1.html' target='_blank''&gt;Cable Extension Transducers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 21 Mar 2008 07:38:55 -0500</pubDate>
        </item>
        <item>
            <title>Automatic Torque Transducers offer analog/digital outputs.</title>
            <link>http://news.thomasnet.com/fullstory/538976</link>
            <description>
MCRT&amp;#174; 48200V Series Digital Torquemeters are compact, non-contact devices with full scale ranges from 25-10,000 lbf-in. They output &amp;#177;10 or &amp;#177;5 V analogs of torque, as well as engineering unit data via resident com port. Calibration values, scaling, and units of measure are stored in nonvolatile memory and automatically loaded on power up, with 10 units supported. Internal signal processing is accurate to 14 bits and devices are offered in accuracy grades of 0.2% and 0.15%.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/torque-transducers-86981008-1.html' target='_blank''&gt;Torque Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/digital-transducers-95989620-1.html' target='_blank''&gt;Digital Transducers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/noncontact-sensors-95901237-1.html' target='_blank''&gt;Non-Contact Sensors&lt;/a&gt;&lt;br&gt;</description>