        <item>
            <title>Flame Ionization Detector delivers accurate hydrocarbon measurement.</title>
            <link>http://news.thomasnet.com/fullstory/568927</link>
            <description>
Servomex SERVOPRO FID provides 100 ppb resolution hydrocarbon measurement, with all flow electronically and temperature regulated. It includes Ethernet/Internet connectivity, allowing users to check parameters or troubleshoot unit offsite. Device's logarithmic amplifier minimizes drift and thermal noise. Lock Range function allows operator to fix unit within desired range, while automatic ranging feature changes measurement parameters according to impurities detected.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ionization-detectors-22151476-1.html' target='_blank''&gt;Ionization Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/flame-detectors-22143200-1.html' target='_blank''&gt;Flame Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 24 Nov 2009 08:33:44 -0500</pubDate>
        </item>
        <item>
            <title>Semi-Volatile Organic Compound Analyzer tests water and soil samples.</title>
            <link>http://news.thomasnet.com/fullstory/568426</link>
            <description>
Based on Agilent 5975C gas chromatograph/mass spectrometer, Semi-Volatile Organic Compound Analyzer provides pre-configured tool for detecting and measuring SVoC in water and soil samples. Capillary Flow Technology, configured for backflushing of heavy matrix, optimizes analysis time and minimizes maintenance needs. Analyzer package also includes Deconvolution Reporting Software and Semi-volatiles DRS database/library with 338 single component analytes from EPA methods 525 and 8270.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/laboratory-research-supplies-equipment' target='_blank''&gt;Laboratory and Research Supplies and Equipment&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/chromatography-equipment-supplies-14033609-1.html' target='_blank''&gt;Chromatography Equipment &amp; Supplies&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/volatile-organic-compound-voc-emissions-monitors-52270907-1.html' target='_blank''&gt;Volatile Organic Compound (VOC) Emissions Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/volatile-organic-compound-voc-emission-detectors-22191282-1.html' target='_blank''&gt;Volatile Organic Compound (VOC) Emission Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-chromatographmass-spectrometers-gc-ms-combined-96153259-1.html' target='_blank''&gt;Gas Chromatograph-Mass Spectrometers (GC/MS) Combined&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 13 Nov 2009 08:31:40 -0500</pubDate>
        </item>
        <item>
            <title>Sensors analyze sulfates and H2S in water plants.</title>
            <link>http://news.thomasnet.com/fullstory/568360</link>
            <description>
To ensure proper water treatment, insertion style Model S10 and valve retractable style Model S17 provide accurate analysis of sulfide levels. Both sensors are fully re-buildable and feature 316 stainless steel body that incorporates sensing element, temperature module, and signal conditioner with cabling. pIon electrode cartridge measures activity of free Sulfide ions in solution in concentrations from 0.01-32,000 ppm over pH range from 11-14 pH. 
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/hydrogen-sulfide-detectors-22151203-1.html' target='_blank''&gt;Hydrogen Sulfide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/hydrogen-sulfide-analyzers-1652288-1.html' target='_blank''&gt;Hydrogen Sulfide Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 11 Nov 2009 08:39:27 -0500</pubDate>
        </item>
        <item>
            <title>Toxic/Flammable Gas Monitor suits low oxygen atmospheres.</title>
            <link>http://news.thomasnet.com/fullstory/567226</link>
            <description>
Packaged in weather-resistant, stainless steel housing, AreaRAE Inert features built-in pump with ability to monitor inert atmosphere using up to 100 ft of sample draw tubing, allowing unit to remain outside of work area and in radio contact with breathing air services and safety managers. Detector may be equipped with up to 5 sensors as application or worksite demands. Wireless range is up to 2 miles and data can be re-transmitted over Internet for remote monitoring and evaluation.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/gas-monitors-52257052-1.html' target='_blank''&gt;Gas Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/toxic-gas-detectors-22182406-1.html' target='_blank''&gt;Toxic Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 16 Oct 2009 08:40:33 -0500</pubDate>
        </item>
        <item>
            <title>Alarm and Control System monitors gas detection sensors.</title>
            <link>http://news.thomasnet.com/fullstory/830119</link>
            <description>
Utilizing microprocessor based control card, Detcon Model 1640 supervises and displays condition of field mounted gas detection sensors. It can monitor up to 16 field devices using RS-485 Serial communications and/or 4-20 mA DC analog devices via Detcon Model DA-4 Addressable I/O Cards. System is available in NEMA 4X weatherproof enclosure or NEMA 7 explosion proof. Back-lit alphanumeric display provides indication of gas type/current reading in normal operation.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/controls-controllers' target='_blank''&gt;Controls and Controllers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/safety-security-equipment' target='_blank''&gt;Safety and Security Equipment&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/control-systems-18111609-1.html' target='_blank''&gt;Control Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/alarm-systems-1041607-1.html' target='_blank''&gt;Alarm Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-detectors-22150403-1.html' target='_blank''&gt;Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 14 Oct 2009 08:33:10 -0500</pubDate>
        </item>
        <item>
            <title>Testing System combines sulfur, nitrogen, and halide detection.</title>
            <link>http://news.thomasnet.com/fullstory/566924</link>
            <description>
Compact, automated, and multi-configurable ANTEK MultiTek(TM) is one testing system capable of detection and analysis of unwanted chemicals, pollutants, contaminants, and corrosive elements. Specifically, it detects sulfur, nitrogen, and halides through process that includes combustion Ion Chromatography, Ultraviolet Fluorescence, and Chemiluminescence technologies. This platform works with solid, liquid, gas, and LPG samples.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/nitrogen-testers-84650803-1.html' target='_blank''&gt;Nitrogen Testers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/sulfur-dioxide-detectors-22182166-1.html' target='_blank''&gt;Sulfur Dioxide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/sulfur-analyzers-1662931-1.html' target='_blank''&gt;Sulfur Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/nitrogen-analyzers-96093133-1.html' target='_blank''&gt;Nitrogen Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-analyzers-1651801-1.html' target='_blank''&gt;Gas Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 09 Oct 2009 08:23:47 -0500</pubDate>
        </item>
        <item>
            <title>Gas Detection Transmitters use variety of sensing elements.</title>
            <link>http://news.thomasnet.com/fullstory/566418</link>
            <description>
Offering array of sensing technologies including hydrogen-specific ppm and LEL versions, GD-70D Series includes LCD display, tri-color bar graph for visual notification of alarm status, programmable low/high alarm relays, and fault relay. Sample-draw transmitters retain all calibration and sensor-specific data in non-volatile memory, allowing sensors to be hot-swapped in field with no programming required. Firmware automatically corrects for long-term zero and span drift.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/smart-transmitters-87440434-1.html' target='_blank''&gt;Smart Transmitters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-sensors-73744856-1.html' target='_blank''&gt;Gas Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/smart-sensors-95932067-1.html' target='_blank''&gt;Smart Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 25 Sep 2009 08:36:19 -0500</pubDate>
        </item>
        <item>
            <title>Toxic Gas Detectors are IP66 rated for harsh environments.</title>
            <link>http://news.thomasnet.com/fullstory/829391</link>
            <description>
Consisting of transmitter (GTX) and sensor module (GTS), GT3000 family electrochemical fixed-point detectors provide non-intrusive calibration and ability to swap sensors without de-classifying hazardous areas. Transmitter generates 4-20 mA output signal with HART that is proportional to concentration of target gas and corresponds directly to 0-100% full scale. Sensors are available to detect hydrogen sulfide, oxygen, carbon monoxide, ammonia, chlorine, hydrogen, and sulfur dioxide.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ammonia-detectors-22140727-1.html' target='_blank''&gt;Ammonia Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/electrochemical-detectors-22142509-1.html' target='_blank''&gt;Electrochemical Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/hydrogen-sulfide-detectors-22151203-1.html' target='_blank''&gt;Hydrogen Sulfide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/sulfur-dioxide-detectors-22182166-1.html' target='_blank''&gt;Sulfur Dioxide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/toxic-gas-detectors-22182406-1.html' target='_blank''&gt;Toxic Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 09 Sep 2009 08:35:59 -0500</pubDate>
        </item>
        <item>
            <title>Data Logging Sensor measures CO&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;, temperature, and humidity.</title>
            <link>http://news.thomasnet.com/fullstory/829017</link>
            <description>
K-33 indoor/outdoor, low-power sensor can store up to 5,400 data points in on-board memory for later download and analysis. With sleep mode enabled, sensor can be powered by 4 AA batteries and remotely record atmospheric conditions for weeks or months. For rapid application prototyping or scientific experiments, SDK enables I2C, UART, analog, and digital outputs via USB connection. Software also allows user to read sensor data log and program parameters for custom applications.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/temperature-humidity-combined-recorders-66431008-1.html' target='_blank''&gt;Temperature &amp; Humidity Combined Recorders&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/data-logging-recorders-66342700-1.html' target='_blank''&gt;Data Logging Recorders&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/carbon-dioxide-sensors-73741829-1.html' target='_blank''&gt;Carbon Dioxide Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/humidity-sensors-73745853-1.html' target='_blank''&gt;Humidity Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-sensors-73754103-1.html' target='_blank''&gt;Temperature Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 19 Aug 2009 08:35:10 -0500</pubDate>
        </item>
        <item>
            <title>Gas Sensors feature gold plated contact pins.</title>
            <link>http://news.thomasnet.com/fullstory/829015</link>
            <description>
Designed for detecting carbon monoxide and hydrogen sulfide, respectively, 4CF+ and 4HS+ are suited for use in single and multi-gas detection instruments for life safety applications. Gold plated pins reduce contact resistance with socket, ensuring performance in applications involving shock or vibration.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/carbon-monoxide-detectors-22141402-1.html' target='_blank''&gt;Carbon Monoxide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/hydrogen-sulfide-detectors-22151203-1.html' target='_blank''&gt;Hydrogen Sulfide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-sensors-73744856-1.html' target='_blank''&gt;Gas Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 19 Aug 2009 08:35:09 -0500</pubDate>
        </item>
        <item>
            <title>Ultrasonic Gas Detection System reduces fire/explosion risk.</title>
            <link>http://news.thomasnet.com/fullstory/564433</link>
            <description>
Combining Gassonic detectors with modular, 6-channel MC600 Controller, ultrasonic gas leak detection system suits range of process safety monitoring applications. It responds to ultrasonic noise generated by escaping gas at pressures as low as 145 psi for 5-20 m coverage radius. Gas leaks are detected regardless of ventilation rates, gas dilution, or direction of leak, and controller lets users configure relays for ultrasonic gas leak detectors and select zones/voting schemes.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/combustible-gas-detectors-22141600-1.html' target='_blank''&gt;Combustible Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ultrasonic-detectors-22190201-1.html' target='_blank''&gt;Ultrasonic Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/leak-detectors-22151609-1.html' target='_blank''&gt;Leak Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 07 Aug 2009 08:37:16 -0500</pubDate>
        </item>
        <item>
            <title>Chlorine Gas Sensor has extended calibration interval.</title>
            <link>http://news.thomasnet.com/fullstory/563564</link>
            <description>
Network-enabled smart gas sensor, 5100-06-IT, is standalone module with integral alarm relays and 6-month (180 day) calibration interval. Integration to existing plant-wide safety and monitoring systems is facilitated via 4-20 mA output, RS-485 Modbus interface, SentryBus interface, optional integral relay output, and digital display. Non-intrusive calibration, remote sensor option, and 316 SS enclosure options are also available.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/gas-sensors-73744856-1.html' target='_blank''&gt;Gas Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-monitors-52257052-1.html' target='_blank''&gt;Gas Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/toxic-gas-detectors-22182406-1.html' target='_blank''&gt;Toxic Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-analyzers-1651801-1.html' target='_blank''&gt;Gas Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ph-chlorine-sensors-73750358-1.html' target='_blank''&gt;pH &amp; Chlorine Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 23 Jul 2009 08:35:59 -0500</pubDate>
        </item>
        <item>
            <title>Toxic Gas Detector supports HART communications protocol.</title>
            <link>http://news.thomasnet.com/fullstory/562290</link>
            <description>
Displaying gas concentrations up to 500 ppm, Model TS4000H offers protection against wide range of hazardous industrial gases and can safeguard against oxygen deficiency. In addition to HART configuration, detector is available in Modbus configuration and with three 8 A relays. All electronics are contained within explosion-proof housing. Interface module's galvanically isolated, intrinsically safe design supports sensor field replacement without special tools or hot work permits.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/toxic-gas-detectors-22182406-1.html' target='_blank''&gt;Toxic Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 30 Jun 2009 08:34:58 -0500</pubDate>
        </item>
        <item>
            <title>CO2/Temperature WiFi Sensor helps conserve energy in buildings.</title>
            <link>http://news.thomasnet.com/fullstory/562219</link>
            <description>
Designed to utilize existing IEEE 802.11 voice/data networks, wall-mounted TR9294-WF can be used to regulate outside air ventilation based on actual number of people in particular space. Signal can be directed over local network to building control system and/or over Internet to any remote monitoring/data collection location. Self-calibrating and maintenance-free sensor uses 24 Vac low-voltage power and supports wireless encryption protocols as well as DHCP or static IP address.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/green-clean' target='_blank''&gt;Green &amp; Clean&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/wireless-sensors-96071667-1.html' target='_blank''&gt;Wireless Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-sensors-73754103-1.html' target='_blank''&gt;Temperature Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/carbon-dioxide-sensors-73741829-1.html' target='_blank''&gt;Carbon Dioxide Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 26 Jun 2009 08:28:05 -0500</pubDate>
        </item>
        <item>
            <title>Multi-Gas Monitor targets industrial and fire applications.</title>
            <link>http://news.thomasnet.com/fullstory/562111</link>
            <description>
Featuring 2-button interface, palm-size Protege Monitor detects oxygen, combustibles, hydrogen sulfide, and/or carbon monoxide. Data logging is based on event changes only, rather than automatic intervals, allowing for capture of relevant analytics while minimizing number of stored data points. Up to 7,000 events can be captured and stored for further analysis. To warn of high gas levels, unit uses bright visual, piercing audible, and vibrating tactile alarm indicators.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/gas-detectors-22150403-1.html' target='_blank''&gt;Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-monitors-52257052-1.html' target='_blank''&gt;Gas Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/data-loggers-data-logging-equipment-21763008-1.html' target='_blank''&gt;Data Loggers &amp; Data Logging Equipment&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 18 Jun 2009 08:30:08 -0500</pubDate>
        </item>
        <item>
            <title>Portable Gas Detector can detect from 1-4 gases.</title>
            <link>http://news.thomasnet.com/fullstory/827288</link>
            <description>
Offered to subscribers of iNet Gas Detection as a Service, MX4 iQuad(TM) features combination of 3 alarms: ultra-bright LEDs, 95 db audible alarm, and vibrating alarm to warn users of hazardous gas levels. Rubber overmold covers it's polycarbonate housing to protect dust-tight unit from high-impact bumps and drops. Decector is also resistant to both water jets and submersion.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/services' target='_blank''&gt;Services&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/toxic-gas-detectors-22182406-1.html' target='_blank''&gt;Toxic Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-detector-service-rental-96010368-1.html' target='_blank''&gt;Gas Detector Service &amp; Rental&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 15 Jun 2009 08:31:28 -0500</pubDate>
        </item>
        <item>
            <title>Gas Detectors measure O2, H&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;S, or CO concentrations.</title>
            <link>http://news.thomasnet.com/fullstory/561328</link>
            <description>
Draeger Pac 3500 gas detectors feature replaceable filter and 2 yr operating lifespan. On Draeger Pac 5500 devices, battery, sensor, and filter can be replaced and units have indefinite lifespan with proper maintenance and servicing. Both are based on triple electrode technology, maximizing sensor life, and allow gas to enter sensor from several directions. This minimizes risk of accidentally covered inlet preventing access to sensor for measurement.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/oxygen-monitors-52260510-1.html' target='_blank''&gt;Oxygen Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/hydrogen-sulfide-detectors-22151203-1.html' target='_blank''&gt;Hydrogen Sulfide Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-detectors-22150403-1.html' target='_blank''&gt;Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/carbon-monoxide-detectors-22141402-1.html' target='_blank''&gt;Carbon Monoxide Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 10 Jun 2009 08:27:58 -0500</pubDate>
        </item>
        <item>
            <title>Gas Monitors help detect or monitor hydrogen peroxide.</title>
            <link>http://news.thomasnet.com/fullstory/827389</link>
            <description>
Offered in range of portable survey monitors to permanently installed multipoint systems, hydrogen peroxide monitoring instruments feature full data acquisition, archiving, and reporting capability. Products come with minimum detectability of 0.05 ppm, and full scale ranges up to 0-1,000 ppm. Suitable applications include sterile processing departments and bio-decontamination in health care industry.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/hydrogen-analyzers-1652262-1.html' target='_blank''&gt;Hydrogen Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-detectors-22150403-1.html' target='_blank''&gt;Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/toxic-gas-monitors-86720679-1.html' target='_blank''&gt;Toxic Gas Monitors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 09 Jun 2009 08:25:16 -0500</pubDate>
        </item>
        <item>
            <title>Ozone Tester determines ozone resistance of rubber.</title>
            <link>http://news.thomasnet.com/fullstory/827160</link>
            <description>
Based on Beer-Lambert law to inspect ozone concentration without use of chemicals, QT-0500 ozone tester provides automatically controlled ozone concentration environment for evaluating resistance of rubber products to cracking during service life. Generated by 185 nm UV-lamp, ozone can be controlled between 0-1,000 pphm for model QT-0500 or 200-30,000 pphm for model QT-0500AC. Temperature can be controlled between 68-194&amp;#176;F, and set values are maintained by PLC control system.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ozone-detectors-22171649-1.html' target='_blank''&gt;Ozone Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/rubber-testers-84710805-1.html' target='_blank''&gt;Rubber Testers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 05 Jun 2009 08:33:40 -0500</pubDate>
        </item>
        <item>
            <title>Combustible Gas Detection System suits range of applications.</title>
            <link>http://news.thomasnet.com/fullstory/826472</link>
            <description>
Offering scalable plant safety solution with voting, IR4000 Infrared Combustible Gas Detection System includes IR4000M Multi-Point Monitor that can connect up to 8 IR400 Point IR gas detectors and read their status with one command, one detector at a time. Versatile monitor incorporates display, relay module, and data concentrator in explosion-proof enclosure and magnetic interface. Certified by FM, CSA, ATEX, CE Marking, and IECEx, system is suited for use in SIL 2 environments.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/gas-monitors-52257052-1.html' target='_blank''&gt;Gas Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/infrared-monitors-52258209-1.html' target='_blank''&gt;Infrared Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/infrared-detectors-22151401-1.html' target='_blank''&gt;Infrared Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/combustible-gas-detectors-22141600-1.html' target='_blank''&gt;Combustible Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 07 May 2009 08:29:38 -0500</pubDate>
        </item>