        <item>
            <title>PEEK-Bodied pH Sensors feature 12 mm form factor.</title>
            <link>http://news.thomasnet.com/fullstory/568241</link>
            <description>
Foxboro&amp;#174; PH12 Series high-performance, disposable pH sensors feature PEEK material body that optimizes durability. Electrochemical sensors include Nafion ion barrier to protect reference junction and nonmetallic solution ground which enables addition of efficient sensor diagnostics. Temperature performance range is from -15 to +125&amp;#176;C and rugged units are also chemical-resistant. Sensors are available with flat, ruggedized glass pH electrode or domed pH electrode.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ph-sensors-73750101-1.html' target='_blank''&gt;pH Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/electrochemical-sensors-96152129-1.html' target='_blank''&gt;Electrochemical Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 05 Nov 2009 08:43:38 -0500</pubDate>
        </item>
        <item>
            <title>Oxygen Sensor suits critical care medical applications.</title>
            <link>http://news.thomasnet.com/fullstory/567037</link>
            <description>
Measuring 33.5 x 30 x 46.5 mm, Paracube&amp;#174; Micro is based on paramagnetic oxygen cell technology and provides full measurement range of 0-100% O2. RoHS-compliant unit offers choice of analog or digital signal output, enabling integration within critical care ventilators, anatomical anesthesia, and patient monitoring applications. Micro can also be used in industrial applications including area monitoring and general gas analysis.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/oxygen-sensors-73749608-1.html' target='_blank''&gt;Oxygen Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/medical-sensors-73748105-1.html' target='_blank''&gt;Medical Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 13 Oct 2009 08:32:15 -0500</pubDate>
        </item>
        <item>
            <title>Nitrate Sensor allows online wastewater treatment monitoring.</title>
            <link>http://news.thomasnet.com/fullstory/565941</link>
            <description>
Hach NO3D sc Nitrate sensor features CARTRICAL technology, which enables plants to monitor nitrogen removal online and view trends in wastewater treatment process. Immersed directly in aeration basin, device uses ion-selective electrode to detect nitrate ions in basin as nitrate nitrogen. Influence of chloride is compensated via integrated electrode, and unit also includes temperature sensor. Sensor cartridge can be replaced in minutes.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/water-quality-sensors-73756157-1.html' target='_blank''&gt;Water Quality Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/remote-sensors-67471953-1.html' target='_blank''&gt;Remote Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 17 Sep 2009 08:29:03 -0500</pubDate>
        </item>
        <item>
            <title>Analytical Sensors precisely determine Ammonium levels.</title>
            <link>http://news.thomasnet.com/fullstory/565343</link>
            <description>
Immersion/insertion S10 and valve retractable S17 sensors are fully re-buildable and feature 316 SS body that incorporates sensing element, temperature module, and signal conditioner with cabling. Replaceable pIon electrode cartridge measures activity of free Ammonium ions in solution with concentrations from 0.5-18,000 ppm over pH range of 2-10 and temperatures from 0 to +40&amp;#176;C. Sensors support integration with C22 Analyzer for automatic pH compensation.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ph-sensors-73750101-1.html' target='_blank''&gt;pH Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/sensors-73740607-1.html' target='_blank''&gt;Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 04 Sep 2009 08:26:15 -0500</pubDate>
        </item>
        <item>
            <title>Oxygen Sensor helps minimize beer losses in filling plants.</title>
            <link>http://news.thomasnet.com/fullstory/563792</link>
            <description>
Based on fluorescence quenching technology, InPro6970i features minimal need for maintenance and calibration. Optical sensor, when connected to transmitter, automatically uploads data which includes information on stresses that sensor has been exposed to, such as number of CIP cycles. From this, current status is relayed to user who can be informed on sensor maintenance requirements.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/oxygen-sensors-73749608-1.html' target='_blank''&gt;Oxygen Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/optical-sensors-73749350-1.html' target='_blank''&gt;Optical Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 04 Aug 2009 08:28:49 -0500</pubDate>
        </item>
        <item>
            <title>Chlorine Gas Sensor has extended calibration interval.</title>
            <link>http://news.thomasnet.com/fullstory/563564</link>
            <description>
Network-enabled smart gas sensor, 5100-06-IT, is standalone module with integral alarm relays and 6-month (180 day) calibration interval. Integration to existing plant-wide safety and monitoring systems is facilitated via 4-20 mA output, RS-485 Modbus interface, SentryBus interface, optional integral relay output, and digital display. Non-intrusive calibration, remote sensor option, and 316 SS enclosure options are also available.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/gas-sensors-73744856-1.html' target='_blank''&gt;Gas Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-monitors-52257052-1.html' target='_blank''&gt;Gas Monitors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/toxic-gas-detectors-22182406-1.html' target='_blank''&gt;Toxic Gas Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-analyzers-1651801-1.html' target='_blank''&gt;Gas Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ph-chlorine-sensors-73750358-1.html' target='_blank''&gt;pH &amp; Chlorine Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 23 Jul 2009 08:35:59 -0500</pubDate>
        </item>
        <item>
            <title>Sensors and Analyzers feature built-in calibration.</title>
            <link>http://news.thomasnet.com/fullstory/558920</link>
            <description>
Eliminating need for field calibration, PERpH-X&amp;#174; pH sensors, Model 6081 wireless analyzer, Model 1056 dual-input analyzer, and Model 1057 multi-parameter analyzer include SMART capability, where embedded calibration is uploaded to analyzer from sensor at start-up. In addition to built-in calibration, sensors also store calibration data, making it possible to monitor and schedule maintenance on sensors from central control room.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ph-sensors-73750101-1.html' target='_blank''&gt;pH Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/particulate-analyzers-1660836-1.html' target='_blank''&gt;Particulate Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ph-analyzers-1660901-1.html' target='_blank''&gt;pH Analyzers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/oxidationreduction-potential-orp-analyzers-96073515-1.html' target='_blank''&gt;Oxidation-Reduction Potential (ORP) Analyzers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 10 Apr 2009 08:29:13 -0500</pubDate>
        </item>
        <item>
            <title>Retractable pH Sensor targets harsh industrial applications.</title>
            <link>http://news.thomasnet.com/fullstory/558588</link>
            <description>
Endura TBX587 Retractable pH sensor is designed for 1 in. NPT process connections found in sample lines in refineries and chemical plants. It includes 316 SS hardware, temperature compensation element located at tip, and T-style handle that aids in insertion and retraction into pressurized process pipelines. Based on solid state, Next Step Reference design, sensor can withstand chemical poisoning and build-up found in chemical processes and slurries.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ph-sensors-73750101-1.html' target='_blank''&gt;pH Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Mon, 06 Apr 2009 08:31:13 -0500</pubDate>
        </item>
        <item>
            <title>PbSe Sensor offers customizable functionality.</title>
            <link>http://news.thomasnet.com/fullstory/555079</link>
            <description>
As 4-color lead selenide (PbSe) sensor, MIRA4 provides sensitivity in detection of up to 4 distinct gases in 1.0-5.5 &amp;#181;m IR region. Customizable 4-element detector comes in one hermetically-sealed, industry-standard T0-5 package and replaces need to use 4 individual element detectors. Areas of use include industrial and medical gas analysis, auto and aviation emissions analysis, underground applications, and general industrial environmental monitoring.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/lead-detectors-22151583-1.html' target='_blank''&gt;Lead Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 03 Feb 2009 08:31:41 -0500</pubDate>
        </item>
        <item>
            <title>PbSe Thermal Imaging Array is optimized for sensitivity.</title>
            <link>http://news.thomasnet.com/fullstory/555026</link>
            <description>
Programmable for use in high-speed applications, LIRA5S 256-element multiplex array comes in 28-pin package and is sensitive in 1.0-5.5 &amp;#181;m wavelength region. It can measure up to 256 discrete thermal points and offers data readout speed of 4 MHz that promotes accelerated analysis. Element size of each lead salt detector in array is 40 microns square on 50 micron centers. Integrated electronics system features ROIC chip designed to work with lead selenide (PbSe) detector material.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/optics-photonics' target='_blank''&gt;Optics and Photonics&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/vision-systems' target='_blank''&gt;Vision Systems&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/thermal-imaging-systems-84891860-1.html' target='_blank''&gt;Thermal Imaging Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/salinity-sensors-73752107-1.html' target='_blank''&gt;Salinity Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/lead-detectors-22151583-1.html' target='_blank''&gt;Lead Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 27 Jan 2009 08:34:42 -0500</pubDate>
        </item>
        <item>
            <title>Optical Sensors measure DO for bioprocess applications.</title>
            <link>http://news.thomasnet.com/fullstory/553628</link>
            <description>
Available in 120, 160, 225, 325, and 425 mm lengths, TruDO Optical sensors are fully autoclavable and use phase fluorimetry to measure dissolved oxygen (DO). Optical approach optimizes measurement response time while minimizing long-term drift. Able to output 4-20 mA analog or ModBus digital signal directly to bioreactor controller, sensors do not require polarization, electrolyte solution, or transmitter and can be used as direct replacement for traditional polargraphic DO sensors.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/dissolved-oxygen-sensors-95975082-1.html' target='_blank''&gt;Dissolved Oxygen Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 07 Jan 2009 08:43:01 -0500</pubDate>
        </item>
        <item>
            <title>Optical Sensor measures dissolved oxygen during fermentation.</title>
            <link>http://news.thomasnet.com/fullstory/822982</link>
            <description>
Based on chemo-optical measurement principle, InPro6880i optical sensor uses light to determine dissolved oxygen during fermentation processes, and does not need electrolytes or require polarization. It comes with integrated electronics, and uses ISM technology that provides sensor diagnostics. Additional status information is analyzed on-line providing user with real-time warnings of end-of-life of marker optical cap.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/dissolved-oxygen-sensors-95975082-1.html' target='_blank''&gt;Dissolved Oxygen Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/optical-sensors-73749350-1.html' target='_blank''&gt;Optical Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 30 Dec 2008 09:02:01 -0500</pubDate>
        </item>
        <item>
            <title>Dissolved Oxygen Monitor features auto-cleaning system.</title>
            <link>http://news.thomasnet.com/fullstory/822763</link>
            <description>
Model Q45D offers 2 measurement sensors; galvanic sensor uses 5 ml Teflon membrane that serves as barrier to allow molecular oxygen to diffuse into reaction cell where sensor produces current proportional to oxygen concentration. Optical system uses fluorescence quenching technique. Both sensor versions incorporate integrated air blast Auto-Clean system to remove materials that build up on sensor membrane. Cleaning cycle is user-selectable to maximize cleaning effectiveness.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/dissolved-oxygen-sensors-95975082-1.html' target='_blank''&gt;Dissolved Oxygen Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/monitor-sensors-95929253-1.html' target='_blank''&gt;Monitor Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 17 Dec 2008 07:41:19 -0500</pubDate>
        </item>
        <item>
            <title>Test Kit screens lead levels in paint.</title>
            <link>http://news.thomasnet.com/fullstory/553425</link>
            <description>
LeadQUICK(TM) Home Paint Kit (487924-V) provides visual test for determining compliance with EPA-recommended maximum level of lead (Pb) in paint (1 mg/cm&amp;#178;). Chemical reactions produce visible color change within 22 min if lead compounds, including lead chromate, are present. Using wedged paint chip that measures all paint layers for lead, kit detects lower levels - from 0.05 to 1.2 mg/cm&amp;#178; - within 13 min. Each kit includes 25 tests.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/test-kits-42031716-1.html' target='_blank''&gt;Test Kits&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/lead-detectors-22151583-1.html' target='_blank''&gt;Lead Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/paint-testers-84670207-1.html' target='_blank''&gt;Paint Testers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 16 Dec 2008 07:33:58 -0500</pubDate>
        </item>
        <item>
            <title>Dissolved Oxygen Sensor withstands pressures up to 145 psi.</title>
            <link>http://news.thomasnet.com/fullstory/822254</link>
            <description>
Featuring maximum error rate of less than 2%, Triton DO8 offers repeatability of &amp;#177;0.5% and resolution of 0.01 ppm or 0.01% saturation. It provides 3 different outputs including 0-20 ppm, 0-200% saturation, or 0-500 psi, withstands ambient temperatures from 0-140&amp;#176;F, and records measurements at 20-120&amp;#176;F.  Self-monitoring unit uses fluorescence quenching (FQ) optical technology coupled with microprocessor-based electronics, and stores calibration data within sensor.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/optical-sensors-73749350-1.html' target='_blank''&gt;Optical Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/dissolved-oxygen-sensors-95975082-1.html' target='_blank''&gt;Dissolved Oxygen Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Tue, 25 Nov 2008 07:47:51 -0500</pubDate>
        </item>
        <item>
            <title>Dissolved Oxygen Sensor is suited for wastewater monitoring.</title>
            <link>http://news.thomasnet.com/fullstory/822152</link>
            <description>
RDO Pro DO Sensor incorporates online optical dissolved oxygen sensor technology, which offers superior resistance to both photo bleaching and abrasion by aggressive process media. Suited for wide variety of municipal and industrial water treatment applications, product employs smart sensor technology, and compliments online liquid analytical sensors for pH/ORP, conductivity, dissolved oxygen, ozone, free chlorine, turbidity, and suspended solids.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/dissolved-oxygen-sensors-95975082-1.html' target='_blank''&gt;Dissolved Oxygen Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/luminescence-sensors-73747503-1.html' target='_blank''&gt;Luminescence Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Thu, 20 Nov 2008 07:54:08 -0500</pubDate>
        </item>
        <item>
            <title>Sterilizable pH Sensor delivers stability and reliability.</title>
            <link>http://news.thomasnet.com/fullstory/550081</link>
            <description>
Designed for life science applications and suited for pharmaceutical manufacturers, autoclavable and steam-sterilizable Rosemount Analytical&amp;#174; PUR-Sense(TM) 3800 exhibits sensor drift below 0.1 pH after autoclave of 125&amp;#176;C for 45 min and continued sensor life after 30+ autoclave cycles or 50 steam cycles. Reliability/stability in high heat is based on PERpH-X&amp;#174; and AccuGlass&amp;#174; technologies, and insertion lengths of 120, 225, and 325 mm are available.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/ph-sensors-73750101-1.html' target='_blank''&gt;pH Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 01 Oct 2008 07:36:11 -0500</pubDate>
        </item>
        <item>
            <title>Flame Ionization Detector measures methane gas.</title>
            <link>http://news.thomasnet.com/fullstory/820380</link>
            <description>
Meeting/exceeding requirements for EPA Federal Reference Method 21 for fugitive gas emissions, MicroFID measures methane in landfill gas, while non-methane components can be measured by adding snap-on charcoal filter capsule. Single tutor key prompts operator through basic operations, and critical data is displayed in less than 3 sec. Unit provides datalogging capability so readings can be stored and downloaded to computer for subsequent analysis and record-keeping purposes.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/methane-sensors-95940441-1.html' target='_blank''&gt;Methane Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/flame-detectors-22143200-1.html' target='_blank''&gt;Flame Detectors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-detectors-22150403-1.html' target='_blank''&gt;Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 10 Sep 2008 07:40:43 -0500</pubDate>
        </item>
        <item>
            <title>Laser Methane Detector is ATEX-approved and weighs 600 g.</title>
            <link>http://news.thomasnet.com/fullstory/548366</link>
            <description>
Measuring 70 x 179 x 42 mm, LaserMethane&amp;#174; mini uses Tunable Diode Laser Absorption Spectroscopy to detect ppm levels of methane from distances up to 100 m. Portable, handheld solution features automatic ranging, color LCD, 5-hr battery, and IP54 construction. Zone 1 area rating allows for on-plant use as well as detecting escapes in hard to reach or inaccessible areas. Unit performs self-check on start-up and verifies operation and calibration of laser diode.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/methane-sensors-95940441-1.html' target='_blank''&gt;Methane Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/gas-detectors-22150403-1.html' target='_blank''&gt;Gas Detectors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Wed, 20 Aug 2008 07:36:33 -0500</pubDate>
        </item>
        <item>
            <title>ORP/pH Sensors provide versatile mounting options.</title>
            <link>http://news.thomasnet.com/fullstory/818987</link>
            <description>
Featuring foul-proof DryLoc connector and Ryton&amp;#174; sensor body to provide chemical compatibility for use in wide range of applications, Models 2724-2726 Signet DryLoc pH/ORP Sensors can mount into standard Signet 0.50-4 in. fittings as well as Georg Fischer tees and off-the-shelf reducing tees &amp;#190; in. or larger. Retrofitting into existing &amp;#190; or 1 in. tees can be done by using reducer bushing. Sensing elements are available in various configurations, and all provide 4-20 mA output.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/sensors-monitors-transducers' target='_blank''&gt;Sensors, Monitors and Transducers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/test-measuring-instruments' target='_blank''&gt;Test and Measuring Instruments&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/oxidationreduction-potential-orp-sensors-73749459-1.html' target='_blank''&gt;Oxidation-Reduction Potential (ORP) Sensors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ph-sensors-73750101-1.html' target='_blank''&gt;pH Sensors&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet News)</author>
            <pubDate>Fri, 01 Aug 2008 07:51:31 -0500</pubDate>
        </item>