<?xml version="1.0" encoding="iso-8859-1"?>
<!-- generator="FeedCreator 1.7.1" -->
<rss version="2.0">
    <channel>
        <title>ThomasNet Industrial Newsroom - </title>
        <description>ThomasNet Industrial Newsroom is a service of ThomasNet.com</description>
        <link>http://news.thomasnet.com</link>
        <lastBuildDate>Sun, 07 Sep 2008 02:36:20 -0500</lastBuildDate>
        <generator>FeedCreator 1.7.1</generator>
        <image>
            <url>http://news.thomasnet.com/images/RSS_logo.gif</url>
            <title>Powered by ThomasNet Industrial Newsroom</title>
            <link>http://news.thomasnet.com</link>
            <width>144</width>
            <height>31</height>
            <description>ThomasNet Industrial Newsroom is a service of ThomasNet.com</description>
        </image>
        <item>
            <title>Air Handling Unit is designed for ease of installation.</title>
            <link>http://news.thomasnet.com/fullstory/515691</link>
            <description>
Available for contactors and distributors, E-Series enhanced model air handler is designed for use with SpacePak air distribution system. Horizontal DX fan coil unit features leak- and rust-proof polyethylene drain pan as well as simplified internal electric cabinet with terminal blocks. Refrigerant connections are located at supply air end of unit for optimal accessibility. Other components include removable return air panel and integral Schrader valve.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 18 Apr 2007 07:36:36 -0500</pubDate>
        </item>
        <item>
            <title>Air Handling Units provide 100% fuel efficiency.</title>
            <link>http://news.thomasnet.com/fullstory/491668</link>
            <description>
Offered in air volumes from 1,000-60,000 cfm and inputs from 0.1-6.5 Mbtu/hr, direct-fired COMBAT&amp;#194;&amp;#174; DF-Series provides multiple installation options, including indoor and outdoor as well as vertical and horizontal configurations. Galvanized steel heaters are available in natural gas or propane gas models with 30:1 fully modulating burner and double-width, double-inlet, forward-curved centrifugal fan that puts 100% of available heat in air stream.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/thermal-heating-equipment' target='_blank''&gt;Thermal and Heating Equipment&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2508&amp;prid=491668&amp;cat=3167&amp;goto=http%3A%2F%2Fwww.tempco.com'&gt;TEMPCO - Electric Heater Corporation&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/directfired-heaters-37505005-1.html' target='_blank''&gt;Direct-Fired Heaters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 22 Aug 2006 08:04:02 -0500</pubDate>
        </item>
        <item>
            <title>Air Handling Units incorporate energy recovery system.</title>
            <link>http://news.thomasnet.com/fullstory/478712</link>
            <description>
Integrated Custom Air Handling (ICA) units in active desiccant dehumidification systems are offered with optional PowerPurge(TM) energy recovery system. PowerPurge collects waste heat off hottest section of desiccant wheel and uses it to help with regeneration, reducing energy required for reactivation while lowering discharge temperature of process air.

&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/energy-recovery-systems-26121277-1.html' target='_blank''&gt;Energy Recovery Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 30 Mar 2006 07:14:13 -0500</pubDate>
        </item>
        <item>
            <title>Vertical Indoor Air Handler has small-footprint design.</title>
            <link>http://news.thomasnet.com/fullstory/465890</link>
            <description>Able to be floor-mounted in closet or mechanical room, Destiny&amp;#226;&amp;quot;&amp;#162; combines blower coil with modular, low-pressure air handler. Full double-wall, foam&amp;#226;¤&amp;quot;injected panel construction facilitates cleaning for improved indoor air quality, while operating static pressure offers flexibility in unit ducting and placement. Suited for applications from 600&amp;#226;¤&amp;quot;15,000 cfm, unit offers multiple coil, filter, and mixing box selections and also comes in horizontal configuration.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 03 Aug 2005 08:08:59 -0500</pubDate>
        </item>
        <item>
            <title>Vertical Indoor Air Handler heats and/or cools buildings.</title>
            <link>http://news.thomasnet.com/fullstory/458474</link>
            <description>Featuring insulated double-wall construction, Model VFC vertical fan coil air handling unit is suited for use in schools, office buildings, and medical facilities. Panels on each side of unit offer access to all internal components, and internal neoprene isolation reduces potential of vibration noise. Equipped with flexible blower connection to housing, unit is available in 7 sizes with capacities from 300&amp;#226;¤&amp;quot;3,500 cfm and up to 3.5 in. wg.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Fri, 17 Dec 2004 07:44:47 -0500</pubDate>
        </item>
        <item>
            <title>Indoor Air Handler suits limited space applications.</title>
            <link>http://news.thomasnet.com/fullstory/455168</link>
            <description>Available in 8 sizes, horizontal Model LFC Low Profile Fan Coil covers performance range from 300&amp;#226;¤&amp;quot;4,700 cfm and up to 3.5 in. wg. It features insulated double wall housing, removable stainless steel drain pan, 4 access panels, and internally-isolated drive frame to help eliminate potential for noise transmitting through ductwork. Unit is suited for cooling and/or heating schools, office buildings, churches, apartments, and condominiums. &lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 02 Sep 2004 07:48:27 -0500</pubDate>
        </item>
        <item>
            <title>Centrifugal Utility Sets handle temperatures to 600&amp;#194;&amp;#176;.</title>
            <link>http://news.thomasnet.com/fullstory/21076</link>
            <description>With Class I or Class II construction, fans offer forward curve, backward inclined, or airfoil wheels in diameters from 7&amp;#226;¤&amp;quot;36 in. Units are AMCA certified for sound and air and are available with UL 705 or UL 762 listings. They are offered in galvanized steel, hot dipped galvanized steel, 6 mil epoxy, stainless steel, or all aluminum. Accessories include variable inlet vanes, outlet shutters, and weather covers.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/centrifugal-fans-27380401-1.html' target='_blank''&gt;Centrifugal Fans&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 08 Apr 2003 07:38:16 -0500</pubDate>
        </item>
        <item>
            <title>Custom Air Handler features double wall construction.</title>
            <link>http://news.thomasnet.com/fullstory/18449</link>
            <description>Integrated Custom Air Handler incorporates no-through metal design in either 2.5 or 4 in. wall thickness. Smooth-fitting panels create fewer joints, preventing leaks, while sloping roof eliminates standing rainwater. Doors are available in inward and outward swinging or plug design. Standard options include chilled water piping, refrigeration packages, filtration, full temperature and humidity controls, face and bypass heating and humidity control.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Mon, 20 Jan 2003 08:13:19 -0500</pubDate>
        </item>
        <item>
            <title>Snow Shield&amp;#226;&amp;quot;&amp;#162; protects filters by melting snow.</title>
            <link>http://news.thomasnet.com/fullstory/17827</link>
            <description>Deep pocket design prevents snow from clogging air filters and diminished air flow into buildings. Design also provides constant drainage, prevents refreezing of snowmelt, and eliminates stagnant water pools. Extracting snow flakes from air as it enters buildings, product installs into factory built air handlers and field built HVAC systems. It is available in various panel sizes for 3,000&amp;#226;¤&amp;quot;30,000 cfm range; multiple panels can handle over 100,000 cfm.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/materials-material-processing' target='_blank''&gt;Materials and Material Processing&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/architectural-civil-engineering' target='_blank''&gt;Architectural and Civil Engineering Products&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2217&amp;prid=17827&amp;cat=3283&amp;goto=http%3A%2F%2Fad.doubleclick.net%2Fclk%3B205493190%3B27545926%3Bm%3Fhttp%3A%2F%2Fwww.usa.siemens.com%2Fanswers%2Fen%2F%3Fpage%3Dindustry%26stc%3D148'&gt;Siemens Corporation - Banner w/DoubleClickTags&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/snow-melting-systems-75981605-1.html' target='_blank''&gt;Snow Melting Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/ice-snow-melters-50491208-1.html' target='_blank''&gt;Ice &amp; Snow Melters&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/snow-filters-75981407-1.html' target='_blank''&gt;Snow Filters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 26 Dec 2002 07:37:40 -0500</pubDate>
        </item>
        <item>
            <title>Flow Converting Devices can be used with blowers.</title>
            <link>http://news.thomasnet.com/fullstory/5671</link>
            <description>Flow-converting devices are for use with regenerative blowers ranging from 1/3 hp to 50 hp. Airflow can instantly change from vacuum to pressure, or can be rerouted to different lines. Flow converting devices can be actuated by 24 VDC, 115 VAC, 220 VAC, or pneumatically, and can be mounted directly to blower or down stream.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/electrical-equipment-systems' target='_blank''&gt;Electrical Equipment and Systems&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2236&amp;prid=5671&amp;cat=612&amp;goto=http%3A%2F%2Fwww.globtek.com'&gt;Globtek Inc. - Your Power Partner...For Over 20 Years!&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/converters-18831909-1.html' target='_blank''&gt;Converters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 02 Jan 2002 13:37:37 -0500</pubDate>
        </item>
        <item>
            <title>Isolation Systems protect against airborne contaminants.</title>
            <link>http://news.thomasnet.com/fullstory/4176</link>
            <description>AirShelter&amp;#226;&amp;quot;&amp;#162; Isolation Systems use HEPA-filtered air to create contained, positive-pressure environments. Their main component is American Air Filter's AstroCel&amp;#194;&amp;#174; II HEPA filter. The combination of positive pressure ventilation(PPV) and HEPA filtration provides filtration levels greater than 99.97% on 1 to 5 micron particles. AirShelter line includes ceiling and floor-mounted HEPA filtration systems and associated monitoring and control equipment.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/fluid-gas-flow-equipment' target='_blank''&gt;Fluid and Gas Flow Equipment&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1674&amp;prid=4176&amp;cat=954&amp;goto=http%3A%2F%2Fwww.swagelok.com'&gt;SWAGELOK  CORPORATION - Pressure Regulators for Industrial Applications&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-handling-systems-770289-1.html' target='_blank''&gt;Air Handling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-purification-systems-840504-1.html' target='_blank''&gt;Air Purification Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/air-filters-28881001-1.html' target='_blank''&gt;Air Filters&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 08 Nov 2001 08:03:00 -0500</pubDate>
        </item>
    </channel>
</rss>
