<?xml version="1.0" encoding="iso-8859-1"?>
<!-- generator="FeedCreator 1.7.1" -->
<rss version="2.0">
    <channel>
        <title>ThomasNet Industrial Newsroom - </title>
        <description>ThomasNet Industrial Newsroom is a service of ThomasNet.com</description>
        <link>http://news.thomasnet.com</link>
        <lastBuildDate>Fri, 10 Oct 2008 23:13:07 -0500</lastBuildDate>
        <generator>FeedCreator 1.7.1</generator>
        <image>
            <url>http://news.thomasnet.com/images/RSS_logo.gif</url>
            <title>Powered by ThomasNet Industrial Newsroom</title>
            <link>http://news.thomasnet.com</link>
            <width>144</width>
            <height>31</height>
            <description>ThomasNet Industrial Newsroom is a service of ThomasNet.com</description>
        </image>
        <item>
            <title>Cold Plate is designed for high power fiber coupled lasers.</title>
            <link>http://news.thomasnet.com/fullstory/819859</link>
            <description>
Model OCP-150 is compact high power 150 W OEM thermoelectric, nickel-plated cold plate to maximize heat spreading for high heat flux laser diodes. It has mounting patterns for nLight's Pearl fiber coupled lasers, LIMO's fiber coupled lasers, and QPC's Brightlase Ultra. Heatsinks for OCP-150 have 3 heatpipes, and all heatpipes and heatsinks are nickel plated and soldered together to maximize heat transfer.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/optics-photonics' target='_blank''&gt;Optics and Photonics&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2038&amp;prid=819859&amp;cat=1782&amp;goto=http%3A%2F%2Fwww.digitalmicroscope.com%2FINRM'&gt;Keyence Corporation of America - The Source for Digital Microscopy Solutions&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cold-plates-61348009-1.html' target='_blank''&gt;Cold Plates&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/thermoelectric-cooling-devices-19651207-1.html' target='_blank''&gt;Thermoelectric Cooling Devices&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/laser-cooling-equipment-43277052-1.html' target='_blank''&gt;Laser Cooling Equipment&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Fri, 22 Aug 2008 07:48:41 -0500</pubDate>
        </item>
        <item>
            <title>Central Cooling Plants have pre-engineered, modular design.</title>
            <link>http://news.thomasnet.com/fullstory/547847</link>
            <description>
Pre-assembled to facilitate installation, modular central plants are suited for new construction and expansion projects where fast-track completion schedules or minimal interruption to cooling are priorities. Solutions combine water-cooled chiller with pumps, cooling tower, and interconnected piping. Chiller models include screw, scroll, centrifugal, or magnetic bearing compressor, depending on requirements, while cooling tower includes VFD as standard. Sizes range from 100-600 tons.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cooling-towers-86680402-1.html' target='_blank''&gt;Cooling Towers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/cooling-systems-19651405-1.html' target='_blank''&gt;Cooling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/water-cooled-chillers-13943501-1.html' target='_blank''&gt;Water Cooled Chillers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 07 Aug 2008 07:46:49 -0500</pubDate>
        </item>
        <item>
            <title>Peltier Devices are offered in compact sizes.</title>
            <link>http://news.thomasnet.com/fullstory/818943</link>
            <description>
Offered in sizes 15 x 15, 20 x 20, and 30 x 30 mm with heights ranging from 3.3-5.1 mm, CPXXXXX Series Peltier Devices have no moving parts and are suited for applications where size and weight are limited. They provide input of 2.0-8.5 A, solder melting point of 138&amp;#176;C, and maximum compress of 98.07 N/cm&amp;#178;. Available with heights from 3.8-4 mm, 40 x 40 mm version features input of 6.0-8.5 A.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/thermal-management-products-96080189-1.html' target='_blank''&gt;Thermal Management Products&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/peltier-thermoelectric-cooling-devices-57616039-1.html' target='_blank''&gt;Peltier Thermoelectric Cooling Devices&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 31 Jul 2008 08:02:47 -0500</pubDate>
        </item>
        <item>
            <title>OEM Thermoelectric Cold Plate has dual butterfly mounts.</title>
            <link>http://news.thomasnet.com/fullstory/546297</link>
            <description>
Featuring 2 model BA-01 butterfly mounts, OCP-050A stabilizes uncooled butterfly lasers using external TECs. It features aluminum cold plate and proprietary thermoelectric modules, which maintain enough cooling capacity for 2 of any high-power pump lasers. Butterfly lasers with internal thermoelectric coolers have lower power due to cooling capacity limit of internal TECs. Uncooled butterfly lasers provide higher power limited only by laser diode itself.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/thermoelectric-cooling-devices-19651207-1.html' target='_blank''&gt;Thermoelectric Cooling Devices&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/thermoelectric-coolers-19631555-1.html' target='_blank''&gt;Thermoelectric Coolers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 08 Jul 2008 07:41:07 -0500</pubDate>
        </item>
        <item>
            <title>Heating and Cooling Coils offered in choice of materials.</title>
            <link>http://news.thomasnet.com/fullstory/542862</link>
            <description>
Coils are manufactured from tube materials consisting of copper, 90/10 cupronickel, SS, or carbon steel. Steam Coils have standard steam and steam distributing coils. Also available are industrial HVAC heating and cooling air-handling coils and plate fin, helical fin, L-footed, and solder-bonded air coils with 3/8-1 in. OD tubing for steam and water applications. Econo Line shell and tube heat exchangers, 4-30 in., are offered in steam-to-liquid or liquid-to-liquid styles.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/thermal-heating-equipment' target='_blank''&gt;Thermal and Heating Equipment&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2508&amp;prid=542862&amp;cat=3167&amp;goto=http%3A%2F%2Fwww.tempco.com'&gt;TEMPCO - Electric Heater Corporation&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/mechanical-components-assemblies' target='_blank''&gt;Mechanical Components and Assemblies&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/air-conditioning-coils-16140808-1.html' target='_blank''&gt;Air Conditioning Coils&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/steam-coils-16300402-1.html' target='_blank''&gt;Steam Coils&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/tubing-coils-16320202-1.html' target='_blank''&gt;Tubing Coils&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/cooling-coils-16160806-1.html' target='_blank''&gt;Cooling Coils&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/heating-coils-16211203-1.html' target='_blank''&gt;Heating Coils&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/shell-tube-heat-exchangers-26641001-1.html' target='_blank''&gt;Shell &amp; Tube Heat Exchangers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 10 Apr 2008 07:34:06 -0500</pubDate>
        </item>
        <item>
            <title>Automatic Fogging Machine features dual timer assembly.</title>
            <link>http://news.thomasnet.com/fullstory/815332</link>
            <description>
Suited for industrial, residential, commercial, and hospitality applications, Model FM920 automatic fogging machine features ceramic piston sleeves for creating pressure of 920 psi. Dual timer assembly, with settings for minutes and seconds, allows users to set exact misting and stop times desired. Pump automatically stops when water supply is interrupted, and 0.1 mm mesh inlet filter prevents debris from entering pump.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/machinery-machining-tools' target='_blank''&gt;Machinery and Machining Tools&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2329&amp;prid=815332&amp;cat=1106&amp;goto=http%3A%2F%2Fwww.omnimetal.com'&gt;Omni Metal Finishing, Inc. - Finishing with Excellence&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/misting-systems-51681534-1.html' target='_blank''&gt;Misting Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/fogging-machinery-46910907-1.html' target='_blank''&gt;Fogging Machinery&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 20 Mar 2008 08:19:46 -0500</pubDate>
        </item>
        <item>
            <title>Tramp Oil Separator features compact design.</title>
            <link>http://news.thomasnet.com/fullstory/814523</link>
            <description>
Intended for use with water-miscible coolants and parts washing fluids, Master Coalescer Jr.(TM) works with CNC machines with small, hard to access coolant sumps. It includes removable media pack that provides up to 132 square ft of coalescing surface, and comes with electric 120 V diaphragm pump that primes to 48 in. Tramp oil separator is also available in portable model that features 2 rigid and 2 swivel casters and hinged pull handle with magnetic latch.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/chemical-processing' target='_blank''&gt;Chemical Processing and Waste Management&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/coolant-recycling-systems-19540764-1.html' target='_blank''&gt;Coolant Recycling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/oil-separators-54640552-1.html' target='_blank''&gt;Oil Separators&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 12 Mar 2008 08:14:16 -0500</pubDate>
        </item>
        <item>
            <title>Thermoelectric Coolers have up to 100 W/cm&amp;#178; cooling power.</title>
            <link>http://news.thomasnet.com/fullstory/804840</link>
            <description>
Supporting maximum temperature difference (delta T) of over 60&amp;#176; Kelvin, Series MPC-D303 microchip thermoelectric coolers (TECs) target laser and photonic sensor manufacturers. Fabricated on silicon wafer using standard semiconductor processes and soldered at 300&amp;#176;C, chip-sized TECs feature cold side area of only 0.98 mm&amp;#178;. With maximum operating temperature of 200&amp;#176;C, they can realize temperature changes faster than 180&amp;#176; K/sec.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/peltier-thermoelectric-cooling-devices-57616039-1.html' target='_blank''&gt;Peltier Thermoelectric Cooling Devices&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/thermoelectric-coolers-19631555-1.html' target='_blank''&gt;Thermoelectric Coolers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Fri, 05 Oct 2007 07:58:47 -0500</pubDate>
        </item>
        <item>
            <title>Cooling Systems protect workers from heat stress, fatigue.</title>
            <link>http://news.thomasnet.com/fullstory/529076</link>
            <description>
Mounted to short and full brim hardhats, PRO-AIR(TM) ACAIR3000(TM) provides forced ambient air throughout headwear to keep workers cool. Microprocessor-controlled unit, powered by rechargeable batteries, offers automatic and manual functions. Also available, ACAIR2000(TM) is designed for arc flash hood applications. It provides continuous air supply to worker while reducing hazardous effects of shield fogging. Rechargeable batteries offer 3 hr of continuous operation per charge.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/safety-security-equipment' target='_blank''&gt;Safety and Security Equipment&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cooling-devices-96085071-1.html' target='_blank''&gt;Cooling Devices&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/cooling-blowers-5760400-1.html' target='_blank''&gt;Cooling Blowers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/personal-safety-products-57722209-1.html' target='_blank''&gt;Personal Safety Products&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 04 Sep 2007 08:16:06 -0500</pubDate>
        </item>
        <item>
            <title>Temperature Controller works with fluid dispensing systems.</title>
            <link>http://news.thomasnet.com/fullstory/528150</link>
            <description>
Peltier series Thermoelectric Temperature Controller combines Peltier thermoelectric device, temperature sensor, and temperature control mounted to manifold where fluid passes through to be heated, maintained, or cooled. Mounted in-line or on fluid dispensing equipment, product uses Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials and heat or cool fluid materials to temperature set point. Accessories are available.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/controls-controllers' target='_blank''&gt;Controls and Controllers&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/peltier-thermoelectric-cooling-devices-57616039-1.html' target='_blank''&gt;Peltier Thermoelectric Cooling Devices&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/temperature-controllers-18200105-1.html' target='_blank''&gt;Temperature Controllers&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Fri, 17 Aug 2007 07:45:46 -0500</pubDate>
        </item>
        <item>
            <title>Cooling Seat Cushion fits most cars, trucks, and SUVs.</title>
            <link>http://news.thomasnet.com/fullstory/504090</link>
            <description>
Utilizing centrifugal fan, SummerSeat pulls in fresh air to cool back and bottom of driver or passenger. Foam cushioning, microfiber mesh, and Eva(TM) Cooling Plastic promotes cool air flow, while adjustable cooling control lets user set desired level of comfort. Product draws minimal power from vehicle's battery and has energy saving automatic shut-off timer that deactivates seat every hour. Optional ac adapter is available for office use.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/mounting-attaching-products' target='_blank''&gt;Mounting and Attaching Products&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/non-industrial-products' target='_blank''&gt;Non-Industrial Products&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/special-property-cushions-96072970-1.html' target='_blank''&gt;Special Property Cushions&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/chair-cushions-21290408-1.html' target='_blank''&gt;Chair Cushions&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/car-cushions-21281803-1.html' target='_blank''&gt;Car Cushions&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/cooling-devices-96085071-1.html' target='_blank''&gt;Cooling Devices&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 10 Jan 2007 08:06:39 -0500</pubDate>
        </item>
        <item>
            <title>Coolant System monitors volume and mix ratios.</title>
            <link>http://news.thomasnet.com/fullstory/493864</link>
            <description>
Mounted to machine coolant tank, Coolant Control Center (CCC) provides continuous real time in-line monitoring of coolant, measuring coolant concentration, PH, conductivity, temperature, and volume. System features PLC for coolant correction and programming routines for precise maintenance of machining fluids. Measuring 16.92 x 38.89 x 11.92 in., CCC has &amp;#190; in. water inlet union and works with 220 V 2-phase electric connector or 400 V 3-phase power hookup.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/machinery-machining-tools' target='_blank''&gt;Machinery and Machining Tools&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=2329&amp;prid=493864&amp;cat=1106&amp;goto=http%3A%2F%2Fwww.omnimetal.com'&gt;Omni Metal Finishing, Inc. - Finishing with Excellence&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/coolant-systems-19540806-1.html' target='_blank''&gt;Coolant Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/machine-tool-coolant-systems-95947263-1.html' target='_blank''&gt;Machine Tool Coolant Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 19 Sep 2006 07:43:43 -0500</pubDate>
        </item>
        <item>
            <title>Chip Conveyor features coolant filtration and separation.</title>
            <link>http://news.thomasnet.com/fullstory/493863</link>
            <description>
ConSep single-platform chip conveyor/coolant separator removes chips and contaminates to 50 microns in size. Separator has internal chip handling (auger) system, which also handles fines and sediment, and backwash that automatically cycles to indexing filter drum's poly fiber media, making unit maintenance free. Clear access panel enables visual inspection of cleaning process, and filtered coolant is held in holding tank for return to machine tool.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/chemical-processing' target='_blank''&gt;Chemical Processing and Waste Management&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/material-handling-storage' target='_blank''&gt;Material Handling and Storage&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/chip-separators-73780207-1.html' target='_blank''&gt;Chip Separators&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/coolant-recovery-systems-19540731-1.html' target='_blank''&gt;Coolant Recovery Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/chip-processing-conveyors-19112408-1.html' target='_blank''&gt;Chip Processing Conveyors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/chip-conveyors-19110600-1.html' target='_blank''&gt;Chip Conveyors&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/coolant-separators-73791204-1.html' target='_blank''&gt;Coolant Separators&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/filtration-systems-29402005-1.html' target='_blank''&gt;Filtration Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 19 Sep 2006 07:43:42 -0500</pubDate>
        </item>
        <item>
            <title>Fluid Recovery System can be moved to any location.</title>
            <link>http://news.thomasnet.com/fullstory/493705</link>
            <description>
Maneuverable in factory aisles, compact system removes solid contaminants from coolant and lubricant fluids used in metalworking processes. It utilizes Centrifuge and Clari-Clean centrifuge bowl cleaner, which are mounted on cart to allow fluid cleaning operation to be brought to any machine. Portable system features 8 gpm circulation system and removes contaminants to standard drum, located on 6 x 3 ft cart.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/fluid-gas-flow-equipment' target='_blank''&gt;Fluid and Gas Flow Equipment&lt;/a&gt; Sponsored by:  &lt;a target='_blank' href='http://news.thomasnet.com/redir.html?lnty=rssad&amp;spclid=1674&amp;prid=493705&amp;cat=954&amp;goto=http%3A%2F%2Fwww.swagelok.com'&gt;SWAGELOK  CORPORATION - Pressure Regulators for Industrial Applications&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/liquid-recovery-filtering-systems-28744449-1.html' target='_blank''&gt;Liquid Recovery Filtering Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/coolant-recovery-systems-19540731-1.html' target='_blank''&gt;Coolant Recovery Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Mon, 18 Sep 2006 07:46:22 -0500</pubDate>
        </item>
        <item>
            <title>Refrigerant Dehydrator operates continuously.</title>
            <link>http://news.thomasnet.com/fullstory/490192</link>
            <description>
Able to process 4,200 lb of refrigerant per week, Model CD-120 removes moisture, acid, sludge, and particulates from any flooded evaporator AC/R refrigeration systems. Totally automatic unit features 4 filter cores and uses only gravity, heat, and pressure differential to operate. For installation, dehydrator requires 120 Vac power supply and two 3/8 in. connections. Refrigerant charge does not have to be pulled to install.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/refrigeration-air-conditioning-system-dehydrators-21980602-1.html' target='_blank''&gt;Refrigeration &amp; Air Conditioning System Dehydrators&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Fri, 28 Jul 2006 08:12:10 -0500</pubDate>
        </item>
        <item>
            <title>Side-Mount Cooling Units condition electronic enclosures.</title>
            <link>http://news.thomasnet.com/fullstory/483768</link>
            <description>
Offered in NEMA 12, NEMA 3R/4, and stainless steel NEMA 4/4X versions, DTS 3000 Series cools electrical and electronic enclosure applications in various industries. Capacities range from 4,000-20,000 BTU, and operating voltages are 115, 230, and 460 Vac. While stainless steel NEMA 4/4X unit is suited for all wash-down related applications, all units feature unobstructed airflow management for optimized cooling performance and energy management.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/electronic-enclosure-cooling-systems-96009808-1.html' target='_blank''&gt;Electronic Enclosure Cooling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/electronics-cabinet-cooling-air-conditioners-700401-1.html' target='_blank''&gt;Electronics Cabinet Cooling Air Conditioners&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 02 May 2006 08:05:54 -0500</pubDate>
        </item>
        <item>
            <title>Cooling Systems maintain enclosure temperature at 80-90&amp;#176;F.</title>
            <link>http://news.thomasnet.com/fullstory/481209</link>
            <description>
Suited for NEMA Type 4 and 4X rated electrical cabinets, UL listed, Vortex A/C(TM) cooling systems are available in 3 models that deliver 900, 1,500, or 2,500 Btu/hr. Units feature noise levels of 62 dBA and operate in environments up to 175&amp;#176;F. Vortex tube technology converts filtered compressed air into low pressure, refrigerated air stream. 
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cooling-systems-19651405-1.html' target='_blank''&gt;Cooling Systems&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/electronic-equipment-coolers-19581800-1.html' target='_blank''&gt;Electronic Equipment Coolers&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/electronics-cabinet-cooling-air-conditioners-700401-1.html' target='_blank''&gt;Electronics Cabinet Cooling Air Conditioners&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/electronic-enclosure-cooling-systems-96009808-1.html' target='_blank''&gt;Electronic Enclosure Cooling Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Thu, 27 Apr 2006 06:32:25 -0500</pubDate>
        </item>
        <item>
            <title>Heat Sinks cool condensed electronic packages.</title>
            <link>http://news.thomasnet.com/fullstory/473306</link>
            <description>
Fabricated from lightweight extruded aluminum, maxiFLOW(TM) heat sinks are utilized for cooling BGAs and hot components inside electronic systems. Featuring low profile spread fin arrays to enable convectional air cooling within restricted/low air flow conditions, they are available in lengths and widths ranging from 10 x 10 mm to 60 x 60 mm, and heights starting at 2 mm. 
 
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/computer-hardware-peripherals' target='_blank''&gt;Computer Hardware and Peripherals&lt;/a&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/heat-sinks-75653808-1.html' target='_blank''&gt;Heat Sinks&lt;/a&gt;  |  &lt;a href='http://www.thomasnet.com/products/cooling-devices-96085071-1.html' target='_blank''&gt;Cooling Devices&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Tue, 24 Jan 2006 07:13:03 -0500</pubDate>
        </item>
        <item>
            <title>Thermoelectric Cooling Modules suit high power laser diodes.</title>
            <link>http://news.thomasnet.com/fullstory/467801</link>
            <description>
Utilizing DCS technology, Cold Plates enable scalable cooling and mitigate heat-spreading problem of using both heatsink and cold plate. Technology is targeted for cooling high power laser diodes such as those found in material processing lasers, medical research, and high power fiber lasers. All cold plates have mounting patterns for most diodes, and custom patterns are available upon request.
&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/cold-plates-61348009-1.html' target='_blank''&gt;Cold Plates&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 05 Oct 2005 06:49:35 -0500</pubDate>
        </item>
        <item>
            <title>Coolant Delivery System provides automatic filtration.</title>
            <link>http://news.thomasnet.com/fullstory/465005</link>
            <description>Capable of removing particles down to 25 microns from emulsions and oils, Turbo Force coolant delivery system automatically back-flushes contaminants into chip conveyor for individual machines or through central filtration system for multiple station operations. Available with pumps offering flow rates of 1-180 gpm at up to 1,750 psi, system is designed for high-volume, high-pressure applications in abrasive milling, turning, and drilling processes.&lt;br&gt;&lt;br&gt;&lt;b&gt;This story is related to the following:&lt;/b&gt;&lt;br&gt;&lt;a href='http://news.thomasnet.com/news/HVAC' target='_blank''&gt;HVAC&lt;/a&gt;&lt;br&gt;&lt;br&gt;Search for suppliers of: &lt;a href='http://www.thomasnet.com/products/coolant-systems-19540806-1.html' target='_blank''&gt;Coolant Systems&lt;/a&gt;&lt;br&gt;</description>
            <author>info@productnews.com (ThomasNet Industrial Newsroom)</author>
            <pubDate>Wed, 29 Jun 2005 08:16:49 -0500</pubDate>
        </item>
    </channel>
</rss>
