document.write('\'Powered'); document.write('
ThomasNet News® - Electrical Equipment & Systems
'); document.write('
ThomasNet News® is a service of ThomasNet.com
'); document.write('
Encapsulated 6 W DC/DC Converter features 4:1 input range.
'); document.write('
'); document.write('Meeting 3rd edition medical safety standard, NCM6 series offers 3 nominal input voltage ranges of 5 Vdc (4.5–9 Vdc), 12 Vdc (9–36 Vdc) or 48 Vdc (18–75 Vdc). Each offers 7 output voltage models: 4 single-output versions (+3.3, +5, +12, and +15 Vdc) and 3 dual output models (+5, +12, and +15 Vdc). Along with 5,200 Vdc input to output isolation, these 20.0 x 32.0 x 10.75 mm, 6 W converters feature -40 to +85°C operating range and input undervoltage lockout.<br />'); document.write(''); document.write('
'); document.write('
Emergency/Exit Light features adjustable LED lamps.
'); document.write('
'); document.write('Measuring 11 ¾ x 12 ½ x 2 3/8 in., Model EESLA-LED is constructed with heavy-duty, premium-grade aluminum housing and 2 fully adjustable LED lamp heads. Back-up battery provides at least 90 minutes of emergency operation. Featuring dual voltage 120/277 Vac operation and push-to-test switch, light is UL listed for damp locations and has universal mounting pattern to facilitate installation. Unit comes with red or green letters and maintenance-free 8.4 V NiCd battery.'); document.write('
'); document.write('
DC-DC Regulators offer 0.1% line regulation.
'); document.write('
'); document.write('Specified with input voltage range of 4.5–22 V, PowerBlox™ XR76108, XR76112, and XR76115 are synchronous step down regulators supporting point-of-load supplies of 8, 12, and 15 A, respectively. Units deliver adjustable output voltage from 0.6–18 V with 1% output accuracy over full temperature range. With emulated current mode Constant On-Time control scheme, regulators provide fast line and load transient response using ceramic output capacitors.'); document.write('
'); document.write('
Infrared LED features flush-mountable design.
'); document.write('
'); document.write('Measuring 3.1 x 1.5 x 1.5 mm with only 0.6 mm extending above and below PC board, side-looking T-shaped Midled SFH 4140 can be integrated into extra-thin smartphones or tablet computers. Transmitter features wavelength of 940 nm and uses integrated reflector to create beam angle of ±25°. Producing 50 mW/sr of typical radiant intensity from 100 mA drive current, device achieves ranges needed for remote control functions.'); document.write('
'); document.write('
Surge Protection Modules suit LED lighting applications.
'); document.write('
'); document.write('Constructed with thermally protected varistors, Models LSP05 and LSP10 protect outdoor LED fixtures with max lightning surge current ratings of 10,000 A and 20,000 A, respectively. LSP05 Module is configured with parallel connections, while LSP10 Module is available with either parallel or series connections. Built-in thermal disconnect function provides additional protection from catastrophic failures and fire hazards. Both provide real-time indication when SPD module needs to be replaced.'); document.write('
'); document.write('
Surge Protector incorporates end-of-life indication.
'); document.write('
'); document.write('Designed to be utilized for luminaires on electrical mains up to 277 V, EOL3-277-20KA series protects luminaires against surges up to 20,000 A. In-line fusing shuts down LED luminaire to protect it until surge protector is replaced, facilitating diagnosis by maintenance crews while promoting protection. When capabilities of surge protector have been exceeded, included LED lights up to indicate that unit needs to be replaced. Models with local and remote LED indicator are available.'); document.write('
'); document.write('
Integrated HPLC Selector serves OEM applications.
'); document.write('
'); document.write('Available in 4, 6, 8, and 10 position configurations, stainless or PEEK, Cheminert C55 Series is designed to be built into OEM systems. Compact assemblies, featuring Cheminert HPLC injector design and 24 V motor, only need to be connected to instrument\'s power supply. Single momentary contact closure steps valve to next position, and separate contact closure moves valve to position 1 (Home). Optional serial (RS232) interface board is available.'); document.write('
'); document.write('
Electric Receptacle combines USB ports, tamper-resistant outlets.
'); document.write('
'); document.write('Along with 2 Type A, 2.0 USB ports that offer 3.6 A charging power, Leviton USB Charger/Tamper-Resistant Duplex Receptacle provides two 15 or 20 A/125 V tamper-resistant receptacles. Design enables charging of up to 2 USB powered electronic devices while leaving 2 tamper-resistant receptacles free for other uses. Smart chip recognizes and optimizes charging power of connected device, and additional receptacle\'s shutter blocks access to contacts from foreign objects to improve safety.'); document.write('
'); document.write('
Remote Switch Actuator fosters safe circuit breaker operation.
'); document.write('
'); document.write('Without requiring any modification to breaker, RSA-69A lets technicians safely close or trip ABB/Sace Megamax F-Series (F1 to F6) low-voltage power circuit breakers (1,200–6,000 A) outside of arc-flash hazard boundary. Applicable CBS ArcSafe® Remote Switch Operator (RSO) control unit enables open and close operation from up to 300 ft away. Utilizing strong magnets, actuator requires no modifications for switchgear mounting, and operators can move actuator from one breaker to another.'); document.write('
'); document.write('
Track Fixtures support MR16 LED and halogen lamps.
'); document.write('
'); document.write('Available in 4 models, Versa Track Series provides accent lighting in applications ranging from restaurant dining or lounge areas to in-store retail displays and residential settings. Integral electronic driver/transformer is rated for 0–60 W. Models include: Versa Cylinder, Versa Gimbal Ring, Versa Wireback, and Versa Roundback. Depending on model, finishes include black, bronze, natural metal, and white.'); document.write('
'); document.write('
DC-DC Converters feature slim, DIN rail-mounted design.
'); document.write('
'); document.write('Housed in 2.99 x 1.24 x 1.02 in. DIN-rail package, Series PYB10-DIN, PYB15-DIN, and PYB20-DIN include 47 modules with output power from 10~20 W. Units offer input ranges of 9~36 Vdc or 18~75 Vdc, with single outputs of 3.3, 5, 12, 15, or 24 Vdc; dual outputs of ±5, ±12, or ±15 Vdc; and triple outputs of 3.3/±12, 3.3/±15, 5/±12, and 5/±15 Vdc. Operating from -40 to +85°C, converters deliver efficiencies reaching 91% with input to output isolation of 1,500 Vdc.'); document.write('
'); document.write('
Power Conversion Driver/MOSFET works with high-performance FPGAs.
'); document.write('
'); document.write('Model ET4040 monolithic 40A driver plus synchronous MOSFET powertrain enables design of point-of-load power solutions. It provides continuous output current over -40 to + 85°C temperature range and input from 4.5-14 V. On-board monolithic current sense maximizes reliability and thermal performance. Powering FPGA core supply rails in single- or multi-phase configurations, unit also suits VDDQ supply rails for DDR3, DDR4, and QDR memories and supplies ASIC and ASSPs in servers and communications systems.'); document.write('
'); document.write('
Industrial Ethernet Switches upgrade networks to Gigabit speed.
'); document.write('
'); document.write('Equipped with 8, 12, or 16 Gigabit Ethernet ports and up to 4 fiber optic ports, EDS-G500E Series withstands harsh conditions and prevents unplanned system downtime. Switches offer severe shock/vibration resistance, Level 4 EMS protection to repel EMI, and thermal fin design that can reduce switch temperatures 5°C or more. Available with Class 1, Div. 2/ATEX Zone 2 ratings, series features redundant Ethernet Turbo Ring, Turbo Chain, RSTP/STP, and MSTP to maximize system reliability.'); document.write('
'); document.write('
Polysulfone Foam is designed for wire and cable applications.
'); document.write('
'); document.write('Providing low-halogen content and low-smoke performance, Udel® P-1703 NT polysulfone (PSU) foam passes NFPA 262 smoke and flame test for plenum (CMP) applications. Resin has specific gravity of 1.24 and foam rate of 50%–60%; latter imparts dielectric constant of 1.8–2 to meet cable electrical requirements without requiring significant modifications to existing constructions. By controlling processing conditions, foaming level can be tuned to 20%–70% closed-cell structure utilized in industry.'); document.write('
'); document.write('
D-Sub Cable Assemblies come in 1 ft length for tight areas.
'); document.write('
'); document.write('CHD Deluxe High Density D-Sub cables and CRMN Deluxe Panel Mount D-Sub cables are available in 1 ft length options to streamline fit and D-Sub connections in space-constricted applications. While CHD cable assemblies are fully shielded throughout to prevent data corrupting EMI/RFI and feature metal thumbscrews to facilitate connections, CRMN cable assemblies feature connectors with threaded inserts and are fully shielded with molded backshells and 26 AWG conductors.'); document.write('
'); document.write('
Power Supplies feature 10-yr electrolytic capacitor lifetime.
'); document.write('
'); document.write('Operating from universal input of 85–265 Vac, ZWS300BAF Series comprises 12, 15, 24, 36, and 48 V models, each adjustable by up to ±10% to accommodate non-standard system voltages. Units operate from -10 to +70°C, allowing 100% load operation in 40°C convection cooled environment and 60% load at 70°C with 1.4 m/s airflow. With active PFC that meets IEC61000-3-2, series has 3 kVac input to output isolation and meets conducted and radiated EMC conforming to EN55011/EN55022B and FCC-B.'); document.write('
'); document.write('
Heavy-Duty Pushbutton Switches suit exterior applications.
'); document.write('
'); document.write('Constructed of brushed stainless steel for use in harsh environments, WR5276 Series carries IP65 rating and includes 4 configurations of exterior grade switches: HD28 Alternate Action Form Z Non-Illuminated, HD28xL Alternate Action Form Z Illuminated LED Ring, HD29 Momentary Action Form Z Non-Illuminated, and HD29xL Momentary Action Form Z Illuminated LED Ring. Switch contacts are isolated NO and NC, and illuminated LED ring color is red or green.'); document.write('
'); document.write('
LED Lamps provide 360 degree light projection.
'); document.write('
'); document.write('Available for internal and external use, EcoLights LED Bulbs contain no mercury or other toxins, emit 0% UV radiation, and are 100% recyclable. Lamps offer instant switch-on, are fully dimmable, and are available in variety of shapes, sizes, and glass renderings. Operating without bulky heat sink of conventional LED lamps, bulbs provide eco-efficient solutions for large scale industry, car parks, warehouses, supermarkets, offices, restaurants, and hotels.'); document.write('
'); document.write('
Universal PMIC offers full design programmability.
'); document.write('
'); document.write('Consisting of quad-output, synchronous step-down PMIC, Model XRP7720 can be programmed to meet needs of nearly all systems. Configurable parameters and functions include output voltage, full feature up and down sequencing, fault behavior, GPIO functionality, and control loop. All are re-configurable through on board FLASH memory. During qualification, system engineer has access to full suite of Power(XR) capabilities such as re-configurability, real-time dynamic control, and telemetry.'); document.write('
'); document.write('
Programmable Quad-Output PMIC monitors system power.
'); document.write('
'); document.write('Compatible with Intel® Node Manager energy monitoring, XRP7725 Synchronous Step-down PMIC offers full control via SMBus compliant I2C interface allowing for advanced local- and remote-reconfiguration, full performance monitoring and reporting, as well as fault handling. Output voltages can be programmed from 0.6–5.5 V without any external components. By sampling current on each of 4 outputs every millisecond and accumulating readings, accuracy of power monitoring is optimized.'); document.write('
');