 Shell and Tube Heat Exchangers have U tube designs.Diversified Heat Transfer, Inc.
Ridgewood, NY 11385
Mar 07, 2008
Available for all heat transfer applications, shell and tube heat exchangers come in horizontal and vertical tube designs. Optional welded tube-to-tube sheet construction promotes strength and sealing qualities. U Tube designs are stress relieved at bend area, and standard shell sizes range from 3-40 in. OD and up to 40 ft long. Products are manufactured to various standards, including those of 3A, ASME, TEMA, and API.
|
Air-to-Air Heat Exchanger suits space-limited applications.Noren Products, Inc.
Menlo Park, CA 94025
Mar 07, 2008
Rated at 700 BTU/hr cooling capacity with efficiency of 10 W/°C, Mighty Mini CC100 provides closed-loop cooling within sealed enclosures, protecting electronics from contamination caused by dirt, oil, humidity, and corrosives. Heat pipe technology removes excess heat from electrical and electronic enclosures, and solution is built as to require minimal maintenance. Areas of application include electrical, electronic, drive, and device control panels.
|
Memory Module Cooler uses integrated heat pipe.Nexus Technology
Nieuwerkerk aan den IJssel Netherlands
Feb 22, 2008
Available in black, blue, and plain aluminum, HXR-5500 features aluminum extrusion heatsink with integrated 5 mm dia heat pipe used to cool memory modules. Heat pipe transports heat from memory module onto detached aluminum heat sink on top of module. By using this product, memory module temperature can be reduced by 13 to 14°C.
|
Heat Exchanger is suited for food industry applications.Solex Thermal Science, Inc. (formerly Bulkflow Technologies, Inc.)
Calgary, AB T2Z3V6 Canada
Nov 20, 2007
Fully enclosed and totally sealed, Bulkflow Heat Exchanger consists of closely spaced, hollow, fully welded heat exchanger plates. Solution eliminates concern for dirt or contamination while indirectly heating or cooling free-flowing powder and bulk solids. Able to integrate with existing equipment, modular solution has mass flow discharge feeder that controls product flow rate and regulates throughput. Static design has no moving parts and ensures gentle product handling.
|
Compact Heat Exchanger provides hot water to restaurants.Turbotec Products, Inc., Div. of Thermodynetics
Windsor, CT 06095
Oct 25, 2007
Compatible with all commonly used refrigerants, Enviro-Pak enables restaurant owners to get free hot water by capturing otherwise wasted heat piped away from refrigeration or central air conditioning systems in 1.5-5 ton range. Heat recovery system uses excess refrigerant energy to reduce water heating equipment load and provide free domestic hot water for cooking and cleaning. Quietly operating system comes with white powder coat or stainless steel jacket.
|
 Sludge Heat Exchanger is jacketed and non-clogging.Komax Systems, Inc.
Wilmington, CA 90748 1323
May 25, 2007
Based on Hi-Pass(TM) non-clogging static mixer, Klean-Flow heat exchanger suits wide range of municipal and industrial applications including municipal sludge digesters, biogas recovery, ethanol production, and animal waste heat recovery. Unit comes with contoured elements to maximize heat transfer while eliminating corners that can trap solid or fibrous materials.
|
 Heat Recovery System captures heat from exhaust gases.MEGTEC Systems
De Pere, WI 54115-5030
Feb 06, 2007
By extracting wasted heat from process dryers, ovens, and air pollution control systems, Process Heat Recovery System heats areas of plant or process. Measuring 4 x 21 ft, unit works with existing or new product lines. It prevents condensation from forming, eliminating disposal issues. System allows choice of heated air delivery or cooling air when ambient conditions permit, and is capable of energy recovery with source temperatures from 200-700°F.
|
 Tube Bundles measure mercury concentrations.Parker Hannifin Corp., Parflex Div.
Ravenna, OH 44266 9137
Feb 02, 2007
Available in continuous lengths up to 1,000 ft, Multitube® Bundles offer consistent high-temperature maintenance and low/high ambient fluctuation durability without need for field input power splice connections. Constant-watt heating element eliminates cold spots that could affect analyzer readings. Even during extreme ambient temperature fluctuation of -30°F, product maintains critical temperature levels consistently with accuracy rating of 99%.
|
Heat Exchanger tolerates thermal variances.Chart Industries, Inc.
Cleveland, OH 44124-4031
Jan 05, 2007
Suitable for applications involving high temperature and large temperature differentials, WPX Welded Plate Heat Exchanger can cover 6,000 square meter surface area and reach pressures up to 1,015 psi. Heat transfer elements allow minor local movements to relieve thermal stresses. Cross-counter-flow heat transfers through corrugated stamped sheets designed to optimize transfer coefficients. Heat exchanger is suited for variety of boiling, condensing, or single-phase flow regimes.
|
 Heat Recovery Unit provides free hot water.Turbotec Products, Inc., Div. of Thermodynetics
Windsor, CT 06095
Dec 12, 2006
Engineered to minimize water heating equipment load, Enviro-Pak hot water maker and heat recovery unit uses excess refrigeration energy of existing or newly installed air-conditioning or refrigeration systems in 1.5-5 ton range. Unit can be used with R-22 or R410a applications, and can provide increase in SEER for older systems up to 3 SEER points. Offered with white powder coat paint or stainless steel jacket, system includes indicator lights for operational and safety diagnostics.
|
Heat and Mass Exchanger provides energy efficient cooling.Delphi
Troy, MI 48098-2815
Dec 05, 2006
Requiring no compressor or chemical refrigerants, HMX Heat and Mass Exchanger enables water-fueled air conditioners to cool homes, office buildings, and industrial spaces without generating greenhouse gas emissions. System capitalizes on thermodynamic M-Cycle, which harnesses endless supply of atmospheric energy to drive cooling. Cooling capacity and Energy Efficiency Ratio increase along with temperature outside, minimizing power consumption during peak demand.
|
Single-Use HME Device works with tracheostomy tubes.Smiths Medical
London NW11 8DS United Kingdom
Nov 07, 2006
Portex® Thermovent® T2 Heat and Moisture Exchange (HME) Device provides humidification for spontaneously breathing patients whose upper airways are bypassed by tracheostomy tube. It includes easy-opening port for suctioning, and oxygen line connection port for supplementary oxygen. Oxygen reservoir end caps are rounded for patient comfort, while clear housing allows visualization of HME. Device may be used for 24 hr max and is suited for patients with tidal volume greater than 70 ml.
|
 Graphite Heat Exchanger utilizes multiple bundles.SGL Carbon Technic, LLC
Strongsville, OH 44149
Sep 28, 2006
Allowing operation in countercurrent flow regime, Model RM Multi-Tube Bundle Exchanger handles applications with close temperature approaches or temperature crosses. Bundle modules can be removed for cleaning, inspection, or replacement. Impervious graphite exchangers are used for heating and cooling corrosive chemicals such as hydrochloric acid, sulfuric acid, and phosphoric acid.
|
 Heat Sinks cool Freescale MPC8641D dual-core processors.Advanced Thermal Solutions Inc.
Norwood, MA 02062
Aug 31, 2006
Featuring integral fan that blows air through linear field of flat aluminum fins, Juneau ATS-405 Active Heat Sink delivers thermal resistance of 0.51°C/W with thermal grease. Developed to cool Freescale processors in restricted height enclosures, Anchorage ATS-474 Passive Heat Sink features maxiFLOW(TM) angled fin technology with thermal resistance of 1.05°C/W in air velocity of 100 lfm and 0.49°C/W in air velocity of 400 lfm.
|
 Heat Sink cools BGA components in low airflow conditions.Advanced Thermal Solutions Inc.
Norwood, MA 02062
Aug 01, 2006
Measuring 9 mm in height, Model EX2 is suited for use inside enclosures where space is limited. Case-to-ambient thermal resistance is 1.8°C/W within air velocity of 600 fpm. Unit can be securely attached to component with double-sided, thermally conductive adhesive tape. No mechanical hardware is required.
|
Air/Water Heat Exchangers cool down electronic enclosures.Pfannenberg
Lancaster, NY 14086
May 30, 2006
Side mount heat exchangers, designed for complete outside or inside cabinet installation, are available in cooling capacities from 650-5,000 W. Suited for use in various industries, they provide thermal management of electrical and electronic enclosures. Each unit features integrated temperature monitoring and compact design with thermostat and solenoid valve for temperature control. Products are sealed and maintenance-free with NEMA 12 rating.
|
Internal Heat Exchanger has double-pipe design.DENSO Corp.
Aichi 448-8661 Japan
Mar 28, 2006
Targeted for automobile air conditioning systems, double-pipe internal heat exchanger integrates 2 pipes into one pipe with inner and outer tubes. Inner tube wall has spiral grooves that face outer tube, which enhance heat exchange and ensure that gap between inner and outer tubes is maintained when pipe is bent during installation into vehicle. Pipe length can be as small as 16 in. to achieve sufficient cooling.
|
Heat Exchanger cools computer room hot spots.IBM (Corporate Headquarters)
Armonk, NY 10504-1783
Mar 21, 2006
Designed for IBM 7014-T42 rack, Model 6858 Rear Door Heat Exchanger enables server density to be increased without increasing cooling requirement in computer room. Water-cooled unit removes up to 50,000 Btu/hr of heat from air exiting back of fully populated rack before it enters room. Rear door design attaches to customer-supplied water, using industry-standard fittings and couplings.
|
 Plate Heat Exchanger handles capacities to 15,585 gpm.Alfa Laval Inc.
Richmond, VA 23231
Oct 28, 2005
Measuring approximately 13 ft, Model T50 has 20 in. port on plate with 38 sq-ft of heat transfer area and is suited for sea cooling applications in large plants. Plate is available in low-theta, medium-theta, and high-theta versions that can be combined in 5 channel combinations to provide optimized design for specific temperature programs. Unit can be supplied with options such as reinforced feet, extended connections, and earthing lugs.
|
 Heat Exchanger has door-mount design.IBM (Corporate Headquarters)
Armonk, NY 10504-1783
May 09, 2005 Able to increase server density without increasing cooling requirements, Rear Door Heat eXchanger is designed to dissipate heat generated from back of computer systems. It attaches to customer supplied water and can dissipate up to 50,000 BTUs of heat from air exiting from back of full rack of servers before it enters room. Unit fits on IBM Enterprise 42U racks. |