Chemical Testers

Test & Measuring Instruments

Modular Analyzer automates aquaculture monitoring.

June 29, 2015

Featuring modular, plug-and-play design, T80-S80 Analyzer System automates testing for dissolved oxygen, pH, ammonia, and other parameters. Rackmount T80 Transmitter, equipped with 2¾ x 1½ in. LCD, is available in loop powered, 24 Vdc line powered, or 110/220 Vac line powered modes. DO80 DO Sensor features measurement range from 0.00–20.00 ppm over temperature range of -10 to +60°C. For pH, S80 offers 0.00–14.00 measurement range with temperature of -10 to +90°C. Read More

Sensors, Monitors & Transducers, Test & Measuring Instruments

Rugged Handheld Tester works with wireless sensors.

June 23, 2015

Offering 1 second response time and wireless distance of 50 ft or more, Model UHH2 Universal Handheld Test Equipment provides functionality of Mobile Meter® Software App on weatherproof IP68 Android®-based handheld. Wireless anemometer, hygrometer, and pressure probes communicate to handheld using Bluetooth SIG, Inc. wireless technology and can all be displayed simultaneously. Powered by 2,000 mAh lithium ion battery, unit includes 1.2 GHz quad-core CPU and 4.3 in. touchscreen. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Green & Clean

Air Quality Station measures gaseous pollutants to ppb level.

May 27, 2015

Weighing less than 1 kg, E4100 measures up to 4 gases – CO, NO, NO2, SO2, H2S, O3, and VOCs – in addition to such basic weather data as humidity, atmospheric pressure, and temperature. Particle counter, also available, includes particle measurements PM 2.5 and PM10 for particles smaller than 2.5 and 10 µm dia. All measurement data can be sent to Web-based database or proprietary systems via wireless Internet connection.

Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Carbon Monoxide Monitor offers audible/visible LED warning.

May 13, 2015

Designed to measure CO concentration, humidity, and air temperature, AQM-103 Series is suited for indoor air quality diagnosis and HVAC performance verification. CE-compliant device features large LCD that shows measurements as well as date and time with programmable high alarm and audible/visible LED warning light for high CO concentration. With CO measurement range from 0–999 ppm, monitor/data logger offers 1 ppm resolution and accuracy of ±5% of reading or ±10 ppm, whichever is greater. Read More

Test & Measuring Instruments

Water Quality Meter uses Android app.

April 27, 2015

With SAM-1 App, SAM-1™ Smart Aqua Meter transforms Android smartphones or tablets into pH, ORP, or Conductivity/TDS meters with integral temperature measurement. Unit plugs into headphone jack of device and connects to Sensorex smart analytical sensors. Instantly recognizing smart sensor, app provides interface for measurements and managing data. Readings can be tagged with GPS location and user comments. Stored data can be transmitted via email and opened in Excel for analysis and reporting. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Multigas Analyzer offers dual measurement capability.

April 23, 2015

Used for production and batch validation of medical-grade gases, SERVOPRO MultiExact 5400 features Gas Filter Correlation (GFX) IR sensors that allow simultaneous monitoring of 0–10 ppm CO and 0–500 ppm CO2 impurities in air, oxygen, or nitrogen. Single-analyzer solution, which offers independent auto-validation/calibration of measurements with option of integrated stream-switching valve block, promotes reliability for each measurement via flow sensor technology. Read More

Test & Measuring Instruments

Total Chlorine Analyzer simplifies water monitoring.

March 26, 2015

Utilizing 3-electrode amperometric sensor, plug-n-play TC-80 monitors total chlorine in drinking water, rinse water, cooling water, or other fresh water samples from 0.05–20 ppm chlorine as standard or 0.005–2.000 ppm with low range sensor. Panel mount design includes built-in flow control and automatic pH compensation. Available with 110-240 Vac or 24 Vdc power, TC-80 graphically displays both Total Chlorine and pH for trend analysis. Unit provides two 4–20 mA outputs and 3 alarm relays. Read More

Materials & Material Processing, Test & Measuring Instruments, Sensors, Monitors & Transducers, Green & Clean

Formaldehyde Meter detects unsafe levels in indoor air.

March 19, 2015

With measurement range of  0–5 ppm, Model FD08 can determine whether flooring, carpeting, drapes, wall board, or other furnishings emit unsafe level of formaldehyde. Handheld Indoor Air Quality tool displays readings on 2 in. LCD with resolution of 0.01 ppm and accuracy of ±(5%+0.03 ppm). Operating from 32–122°F, Model FD08 can also measure workplace levels in manufacturing facilities and warehouses where formaldehyde is used in resins and bindings, or as process chemical. Read More

Test & Measuring Instruments

Water Tester simplifies chlorine demand measurement.

March 16, 2015

Measuring amount of chlorine consumed by ammonia, iron, manganese, and other organic materials, CD-2000 provides advanced information such as Chlorine Demand in raw water. Corresponding amount of chlorine is added to achieve clean water with consistent level of residual chlorine. Suited for daily control and research purposes, instrument can measure chlorine demand in diverse water types and provide measurement without interference from turbidity or color of water. Read More

Test & Measuring Instruments

Packaging Tester measures oxygen permeability.

January 30, 2015

With 3 integrated test cells, I-Oxtra 7700 Oxygen transmission Rate Testing System is designed to improve test efficiency and minimizes space requirements. System is designed according to ASTM D3985 (based on equal pressure method) as well as ASTM F2622, ASTM F1307, ASTM F1927, and ISO 15105-2. Film test ranges of 0.01–6,500 cm³•d (standard) and 0.07–65,000 cm³•d (optional) offer 0.001 cm³/m²•d resolution, while package test range of 0.0001–60 cm³/m²•d offers 0.00001 cm³/pkg•d resolution. Read More

Test & Measuring Instruments

Environmental Test Kits include tablet PC.

January 5, 2015

Available with 7, 8, or 10 in. tablet PC, DirectSense® TAB Kits are suited for IAQ, TVOC, TOX, HVAC, and AIR applications. All tablets come with cameras that enable direct attachment of photos and video to data files on-site. Smaller tablets support up to 6 sensors, while some 8 in. and all 10 in. versions accommodate 32 sensors simultaneously. Via included WiFi card, 10 in. tablet empowers optional GrayWolfLive™ cloud software for remote access to logged files, and optional remote alerts/alarms. Read More

Test & Measuring Instruments

Indoor Air Quality Meter measures CO2, air temp, RH, and more.

October 17, 2014

Leveraging NDIR (non-dispersive infrared) technology, 800046 can be used to monitor IAQ in spaces as well as test air from HVAC equipment. Backlit simultaneous display shows CO2 level from 0–5,000 ppm, humidity from 0–100%, and air temperature from 14 to 140°F. User can also choose rotating display of dew point (8 to 140°F) and wet bulb temperature (-100 to 140°F) instead of air temperature. Additional calculations cover TWC (Time Weighted Average) and STEL (Short-Term Exposure Limit). Read More

Test & Measuring Instruments

Test System measures oxygen permeability of contact lenses.

July 15, 2014

Based on equal pressure/coulometric method, i-OXTRA 7700 measures oxygen transmission rate of various films, sheeting, and finished packages. System offers test range of 0.01~6500 cm³/m²-d with resolution of 0.001 cm³/m²-d. Capable of testing 3 distinct or identical specimens with individual test results, i-OXTRA 7700 can be connected with maximum of 9 satellite bases to perform up to 30 tests simultaneously. Analyzer is equipped with 4 USB ports and dual Internet ports for data transmission. Read More

Test & Measuring Instruments

Total Hydrocarbon Analyzer provides long term stability.

June 2, 2014

Employing flame ionization detector (FID), Series 2300 is used to continuously measure concentrations of hydrocarbons in gas streams. Optional catalytic methanizer enables CO and CO2 measurement, and alternative version is available for beverage-grade CO2 applications. Microprocessor-controlled instrument displays concentration in ppm or ppb on graphical LCD touchscreen, which is accompanied by membrane keypad for navigation through settings and functions. Read More

Test & Measuring Instruments, Controls & Controllers, Sensors, Monitors & Transducers

Carbon Dioxide Probe supports high sterilization temperatures.

May 20, 2014

Featuring Microglow IR light source, CARBOCAP® Carbon Dioxide Probe GMP231 provides incubator manufacturers with carbon dioxide (CO2) measurements and sterilization durability at up to 180°C. This enables facilitated and complete sterilization of incubator with probe in place. Along with 4-point NIST traceable calibration for CO2, features include CO2 sensor measurement optimized for 5% CO2, measurement range of up to 20% CO2, and full temperature and pressure compensation. Read More

Test & Measuring Instruments

Oxygen Permeability Tester works with flexible packaging.

May 14, 2014

Designed on principle of electrochemistry according to ASTM F1307 and ASTM D3985, i-Oxtra 7700 simultaneously possesses function of container and quantity testing of permeable oxygen, with testing accuracy up to 0.0001 ml/pkg /day. This flexible package testing instrument features oxygen cavity and can satisfy permeability testing for various kinds of plastic packaging. In additional to performing test in open air, instrument can complete testing with oxygen concentration of 100%. Read More

Test & Measuring Instruments, Laboratory and Research Supplies & Equipment

Lab-Grade Instrument measures temperature, velocity, pressure.

May 9, 2014

Preloaded with IQstage™ DAQ software, iQ-200™ measures temperatures of solid materials and surrounding air from -40 to 750°C while also tracking air velocity from 0–1,200 fp (standard) or 0–10,000 fpm (custom) and air pressure (0–0.15 psi). Measurements are taken simultaneously at multiple points to accurately profile heat sinks, PCBs, and card racks for testing and characterization. Instrument connects via USB to PC for data management, storage, and sharing. Read More

Test & Measuring Instruments, Materials & Material Processing

DEF Hydrocarbon Contamination Test produces results in 20 sec.

March 28, 2014

Requiring ~30 ml sample size and 20 sec immersion, ACU480508 helps DEF manufacturers and distributors and others mitigate risk of using unacceptable DEF. This dip-and-read tests, which enables early detection of hydrocarbon contamination, is also suitable for testing presence of hydrocarbons in antifreeze coolant and water. Presence of hydrocarbons causes black spots on test strips that can be compared to chart to determine contamination level. Read More

Test & Measuring Instruments

Permeability Test System indicates oxygen transmission rate.

March 21, 2014

Based on equal pressure/coulometric method, i-Oxtra 7700 measures oxygen transmission rate (OTR) of various films, sheeting, and finished packages. System integrates 3 test cells, promoting operational efficiency while reducing space requirements. Film test ranges are 0.01–6,500 cm³/m²·d (standard) and 0.07–65,000 cm³/m²·d (optional), both with 0.001 cm³/ m²·d resolution. Optional package test has 0.0001–60 cm³/pkg·d range and 0.00001 cm³/pkg·d resolution. Read More

Test & Measuring Instruments

Spectroscopic Probes support continuous NIR monitoring.

March 4, 2014

Used for on-line analysis of hydrocarbon process streams, FCP-020 withstands demanding conditions, including continuous 24/7 outdoor operation, and features window sealing technique involving direct sapphire to metal welded pressure seal. Sapphire, high nickel alloys, and thin layer of gold or PTFE are only materials in contact with process, ensuring chemical resistance. High nickel alloy seal, compressed at high pressure prior to welding, enables extreme temperature cycling resistance. Read More