Chemical Testers

Test & Measuring Instruments

Packaging Tester measures oxygen permeability.

January 30, 2015

With 3 integrated test cells, I-Oxtra 7700 Oxygen transmission Rate Testing System is designed to improve test efficiency and minimizes space requirements. System is designed according to ASTM D3985 (based on equal pressure method) as well as ASTM F2622, ASTM F1307, ASTM F1927, and ISO 15105-2. Film test ranges of 0.01–6,500 cm³•d (standard) and 0.07–65,000 cm³•d (optional) offer 0.001 cm³/m²•d resolution, while package test range of 0.0001–60 cm³/m²•d offers 0.00001 cm³/pkg•d resolution. Read More

Test & Measuring Instruments

Environmental Test Kits include tablet PC.

January 5, 2015

Available with 7, 8, or 10 in. tablet PC, DirectSense® TAB Kits are suited for IAQ, TVOC, TOX, HVAC, and AIR applications. All tablets come with cameras that enable direct attachment of photos and video to data files on-site. Smaller tablets support up to 6 sensors, while some 8 in. and all 10 in. versions accommodate 32 sensors simultaneously. Via included WiFi card, 10 in. tablet empowers optional GrayWolfLive™ cloud software for remote access to logged files, and optional remote alerts/alarms. Read More

Test & Measuring Instruments

Indoor Air Quality Meter measures CO2, air temp, RH, and more.

October 17, 2014

Leveraging NDIR (non-dispersive infrared) technology, 800046 can be used to monitor IAQ in spaces as well as test air from HVAC equipment. Backlit simultaneous display shows CO2 level from 0–5,000 ppm, humidity from 0–100%, and air temperature from 14 to 140°F. User can also choose rotating display of dew point (8 to 140°F) and wet bulb temperature (-100 to 140°F) instead of air temperature. Additional calculations cover TWC (Time Weighted Average) and STEL (Short-Term Exposure Limit). Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Electrochemical Air Quality Monitor delivers ppb accuracy.

September 15, 2014

Designed for integration with existing systems, Envitems E6100 can measure common gaseous sources of urban air pollution — NO2, NO, SO2, CO, HS2, and O3 — and offers option to add particulate detectors. Electrochemical technology enables measurement down to ppb level, and users can wirelessly download data recordings. Compact air quality station, capable of precision measurement, suits research and urban air quality monitoring applications. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Laboratory and Research Supplies & Equipment

Flame Ionization Detector is unaffected by background gases.

August 28, 2014

Part of 9100 Series On-Line Gas Chromatograph, Flame Ionization Detector provides detection capabilities for hydrocarbon compounds and other VOCs. Chromatograph offers fully integrated GC software, programmable touchscreen, and USB interface. For unattended operation, unit features remote access and control, automatic calibration, and internal data storage. Other attributes include LAN connection, analog outputs, multipoint sampling, and graphical display of current or historic concentrations. Read More

Test & Measuring Instruments

Test System measures oxygen permeability of contact lenses.

July 15, 2014

Based on equal pressure/coulometric method, i-OXTRA 7700 measures oxygen transmission rate of various films, sheeting, and finished packages. System offers test range of 0.01~6500 cm³/m²-d with resolution of 0.001 cm³/m²-d. Capable of testing 3 distinct or identical specimens with individual test results, i-OXTRA 7700 can be connected with maximum of 9 satellite bases to perform up to 30 tests simultaneously. Analyzer is equipped with 4 USB ports and dual Internet ports for data transmission. Read More

Test & Measuring Instruments

Total Hydrocarbon Analyzer provides long term stability.

June 2, 2014

Employing flame ionization detector (FID), Series 2300 is used to continuously measure concentrations of hydrocarbons in gas streams. Optional catalytic methanizer enables CO and CO2 measurement, and alternative version is available for beverage-grade CO2 applications. Microprocessor-controlled instrument displays concentration in ppm or ppb on graphical LCD touchscreen, which is accompanied by membrane keypad for navigation through settings and functions. Read More

Test & Measuring Instruments, Controls & Controllers, Sensors, Monitors & Transducers

Carbon Dioxide Probe supports high sterilization temperatures.

May 20, 2014

Featuring Microglow IR light source, CARBOCAP® Carbon Dioxide Probe GMP231 provides incubator manufacturers with carbon dioxide (CO2) measurements and sterilization durability at up to 180°C. This enables facilitated and complete sterilization of incubator with probe in place. Along with 4-point NIST traceable calibration for CO2, features include CO2 sensor measurement optimized for 5% CO2, measurement range of up to 20% CO2, and full temperature and pressure compensation. Read More

Test & Measuring Instruments

Oxygen Permeability Tester works with flexible packaging.

May 14, 2014

Designed on principle of electrochemistry according to ASTM F1307 and ASTM D3985, i-Oxtra 7700 simultaneously possesses function of container and quantity testing of permeable oxygen, with testing accuracy up to 0.0001 ml/pkg /day. This flexible package testing instrument features oxygen cavity and can satisfy permeability testing for various kinds of plastic packaging. In additional to performing test in open air, instrument can complete testing with oxygen concentration of 100%. Read More

Test & Measuring Instruments, Laboratory and Research Supplies & Equipment

Lab-Grade Instrument measures temperature, velocity, pressure.

May 9, 2014

Preloaded with IQstage™ DAQ software, iQ-200™ measures temperatures of solid materials and surrounding air from -40 to 750°C while also tracking air velocity from 0–1,200 fp (standard) or 0–10,000 fpm (custom) and air pressure (0–0.15 psi). Measurements are taken simultaneously at multiple points to accurately profile heat sinks, PCBs, and card racks for testing and characterization. Instrument connects via USB to PC for data management, storage, and sharing. Read More

Test & Measuring Instruments, Materials & Material Processing

DEF Hydrocarbon Contamination Test produces results in 20 sec.

March 28, 2014

Requiring ~30 ml sample size and 20 sec immersion, ACU480508 helps DEF manufacturers and distributors and others mitigate risk of using unacceptable DEF. This dip-and-read tests, which enables early detection of hydrocarbon contamination, is also suitable for testing presence of hydrocarbons in antifreeze coolant and water. Presence of hydrocarbons causes black spots on test strips that can be compared to chart to determine contamination level. Read More

Test & Measuring Instruments

Permeability Test System indicates oxygen transmission rate.

March 21, 2014

Based on equal pressure/coulometric method, i-Oxtra 7700 measures oxygen transmission rate (OTR) of various films, sheeting, and finished packages. System integrates 3 test cells, promoting operational efficiency while reducing space requirements. Film test ranges are 0.01–6,500 cm³/m²·d (standard) and 0.07–65,000 cm³/m²·d (optional), both with 0.001 cm³/ m²·d resolution. Optional package test has 0.0001–60 cm³/pkg·d range and 0.00001 cm³/pkg·d resolution. Read More

Test & Measuring Instruments

Spectroscopic Probes support continuous NIR monitoring.

March 4, 2014

Used for on-line analysis of hydrocarbon process streams, FCP-020 withstands demanding conditions, including continuous 24/7 outdoor operation, and features window sealing technique involving direct sapphire to metal welded pressure seal. Sapphire, high nickel alloys, and thin layer of gold or PTFE are only materials in contact with process, ensuring chemical resistance. High nickel alloy seal, compressed at high pressure prior to welding, enables extreme temperature cycling resistance. Read More

Test & Measuring Instruments

Gas Analyzer provides ultra-trace purity measurements.

February 19, 2014

Designed specifically for contaminant gases and hydrocarbons that can be present at ultra-trace levels in semiconductor manufacture, SERVOPRO NanoChrome provides sub-ppb measurement of H2, CH4, CO, CO2, and NMHC in range of common background gases including He, H2, N2, Ar, and O2. In addition to high-sensitivity Plasma Emission Detector, analyzer utilizes adaptive chromatographic filtering methods and ProPeak peak detection techniques for sensitive and selective measurement. Read More

Test & Measuring Instruments, HVAC

Indoor Air Quality Monitor offers real-time data logging.

December 23, 2013

Featuring compact, handheld design, AQ Pro measures CO2, temperature, % RH, barometric air pressure, and differential pressure as standard, but can be upgraded to also measure VOC, formaldehyde, O2, NO2, SO2, and H2S. Unit includes active internal sampling pump, magnetic rubber boot, and Bluetooth. Powered by rechargeable Li-ion battery, monitor is suited for use in hospitals, schools, labs, cleanrooms, and airports. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

CO2 Display measures humidity and temperature.

October 1, 2013

Equipped with ROTRONIC HYGROMER® IN-1 humidity sensor, CO2 Display provides 18,000 data point memory for simultaneous measurement and recording of CO2, relative humidity, and temperature. Instrument can be configured directly with buttons and provides accuracy of ±2.5 % RH / ±0.3 K / ±30 ppm +5% of measured value. Suitable for wall-mounting or bench-top operation, indoor air quality analyzer allows stored data to be exported to USB stick for analysis with software. Read More

Test & Measuring Instruments, HVAC, Green & Clean

Portable Indoor Air Quality Monitor offers up to 11 parameters.

August 15, 2013

Supporting parameter customization to meet application requirements, AQ Expert provides monitoring and real-time data logging for IAQ testing in hospitals, buildings, schools, labs, clean rooms, and airports. Bluetooth- and USB-enabled unit, powered by Li-ion rechargeable battery, features internal memory and measures CO2, CO, %RH, temperature, VOC, O2, NO2, Ozone, SO2, H2S, and barometric air pressure. Other features include active internal sampling pump and software. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Infrared Analyzer measures oil in off-shore drill cuttings.

August 6, 2013

Weighing less than 5 lb, Portable InfraCal Analyzer measures hydrocarbons at 3.4 micrometers. Fixed-filter mid-infrared analyzer is designed with no moving parts and has user interface specifically designed for non-technical users. For analysis procedure, sample is collected in container and solvent is added at ratio of 1 part solvent to 10 parts sample. After shaking for 2 minutes, solvent partitions and portion of solvent is introduced to infrared analyzer for measurement. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Universal Analyzer integrates predictive maintenance.

July 31, 2013

Equipped with 2 ¾ x 1 ½ in. LCD, single-channel Model T80 Universal Transmitter provides continuous measurement of pH, ORP, pION, dissolved oxygen, turbidity, conductivity, or resistivity. Transmitter digitally communicates with any Model S80 Intelligent Sensor, automatically uploading calibration data and configuring transmitter's menus and display screens. SENTINEL technology alerts maintenance technicians to sensor electrode wear so that sensor electrodes are replaced only as necessary. Read More

Test & Measuring Instruments, Software, Sensors, Monitors & Transducers, Green & Clean, Services

Air Quality Monitor helps increase health care facility safety.

July 31, 2013

Used to monitor events which can create undesirable environmental air conditions, IC Sentinel distributed, networked sensor and software suite generates real-time and long-term air quality metrics in hospitals and healthcare facilities. Solution provides particulate level, differential room pressure, humidity, and CO2 level metrics related to control of airborne particulates. Monitor can also provide sound and light levels, which can be associated with patient satisfaction studies. Read More