|
|
Advertisement
|
|
Test & Measuring Instruments ->
Probes ->
Radiation Probes
Radiation Probes
(Showing headlines 1 - 17)
|
Digital X-Ray Detector delivers 9.4 megapixel resolution.Samsung Electronics Co., Ltd.
Seoul 100-742 Korea (south)
Jan 11, 2008
Intended for radiology machines, flat panel X-ray detector (FPXD) combines digital imaging with TFT technology to eliminate need for film and development process. Solution features 45 x 46 cm screen and 3,072 x 3,072 resolution for delivery of ultra-high definition images. Image enhancement function eliminates most digital image noise interference. In addition to X-ray systems, applications include CAT scans, building inspections, and airport security scanners.
|
LC Detector can analyze non-ionizable compounds.Agilent Technologies, Inc
Santa Clara, CA 95051
Jan 08, 2008
Series 1200 evaporative light scattering detector (ELSD) offers isocratic and gradient analysis of non- and semi-volatile compounds independent of compound's absorbance, fluorescence, or electro-activity. Liquid chromatography (LC) detector features applicability for Rapid Resolution Chromatography (RRLC) with peak widths of 1 sec, 4 nebulizers to cover all HPLC techniques from low l-to semi-preparative flow rates, and convenient front access to facilitate inspection and maintenance.
|
X-Ray Inspection System suits packaged and bulk products.Mettler Toledo, Inc.
Columbus, OH 43240
Dec 26, 2007
Offering mass detection with belt width options of 300, 400, and 600 mm, AdvanChekPlus uses low energy X-ray technology to detect and reject contaminants including metal, stone, glass, and bone, even when packaged in metal foil. It features user-intuitive color touch screen interface, automatic set-up, and modular design. Unit comes in washdown protected NEMA 12 enclosure which is upgradeable to NEMA 4X for high pressure, hot, or caustic washdown environments.
|
 Silicon Drift Detector is capable of low-energy detection.Thermo Fisher Scientific
Waltham, MA 02454
Aug 16, 2007
Suited for electron microscopes, UltraDry offers capabilities that allow for detection of low-energy X-rays down to Beryllium. Clear peak separations in low-energy region facilitate interpretation of spectra and promote confidence in analysis, while X-ray detection performance allows for collection of data at optimized count rates without affecting energy resolution or light element sensitivity. Large-area detector can be coupled with NORAN System SIX and Direct-to-Phase software.
|
 Eddy Current Probe operates in temperatures to 240°C.Sensonics
Berkhamsted Hertfor HP1 1EF United Kingdom
Jul 05, 2007
Used to monitor rotating shaft alignment and axial position, PRS05 Senturion Proximity Probe is constructed with bobbin expansion chamber and wire strain relief techniques for high-temperature operation. Construction also includes glass-filled PPS bobbin case, rated to 300°C, resistant to oil and chemicals. Offering 0-5 mm non-contact measurement range in 12 mm tip (M18 body) configuration, probe maintains measurement error of less than 5% over full range.
|
UV Sensor comes with calibration capability.EMX Industries, Inc.
Cleveland, OH 44128
May 15, 2007
Series UVX-300-GC UV luminescence sensors provide calibration through proprietary software algorithms that offers one-time calibration of all sensors before distribution in system. Sensors are used on assembly lines to detect presence or absence of components such as O-ring seals, adhesives, labels, paint, and lubricants. They can also detect transparent objects. Units offer remote lock feature that prevents unauthorized changes to sensor settings.
|
X-Ray Molecular Spectrometer helps identifiy potential threats.Optosecurity Inc.
Québec G1P 4S4 Canada
Dec 06, 2006
Interpreting standard checkpoint 2-D X-Ray tomography to identify containers and their contents, Optosecurity XMS (X-Ray Molecular Spectrometer) recognizes potential threats according to their unique molecular signatures and identifies innocuous materials and liquids that may be assembled into explosives. Product can be connected to existing x-ray checkpoint systems to improve threat detection and works inline without requiring secondary offline processes.
|
 UV Luminescence Sensor has long-range, high-speed operation.Balluff, Inc.
Florence, KY 41042-0937
Nov 17, 2006
Able to detect UV luminescent materials/markers over distances to 300 mm, BLT 31M combines adjustable light projection and high resolution to suit part detection and error proofing applications. Sensing range helps avoid incidental contact in manufacturing process, while 6 kHz response time suits high-speed applications. With optional 50 mm lens, projected light can be directed into 5 mm spot. Sensor includes auto-teach and manual programming as well as analog and discrete outputs.
|
EDS System features 4-channel detector.BRUKER AXS Inc
Madison, WI 53711-5373
Apr 26, 2006
Powered by ESPRIT(TM) software, QUANTAX(TM) QUAD is designed for X-ray microanalysis on electron microscopes. It features 4-channel XFlash® QUAD Detector, which consists of 4 independently operating, 10 mm² Silicon Drift Detectors with integrated anodes and FETs. Cooled by Peltier elements, XFlash requires no liquid nitrogen and is maintenance-free. It accepts max input count rates in excess of 2,000,000 cps with standard energy resolution better than 133 eV at 10,000 cps.
|
LC System works with PDA, TUV, and ELS detectors.Waters Corp.
Milford, MA 01757
Feb 01, 2006
Waters® ACQUITY UPLC(TM) Ultra Performance LC(TM) (UPLC(TM)) is available with photodiode array (PDA), evaporative light scattering (ELS), and tunable ultraviolet (TUV) detectors for high-resolution analysis of compounds. Liquid chromatography (LC) system enables control over detector programming and monitoring from within Waters Empower(TM) chromatography software or MassLynx(TM) mass spectrometry software. PDA and TUV detectors support data rates to 80 Hz.
|
 Flame Detectors monitor for hydrocarbon-based fires.Mine Safety Appliances Company / Instrument Division
Pittsburgh, PA 15230
Dec 06, 2005
Designed to detect UV and/or IR radiation emitted by hydrocarbon-based fires and flames, FlameGard Detectors operate as stand-alone units or can be connected to fire or security system. They are enclosed in copper-free, explosion-proof aluminum housings and can be mounted with bracket or optional swivel mount kit. In dusty environments, optional air purge kit keeps viewing glass clear. Detectors are FM approved and include false alarm suppression.
|
 X-Ray Detector suits protein crystallography.Bruker AXS GmbH
Germany
Sep 02, 2005
Designed for macromolecular X-ray crystallography, ÅXIOM 200 has essentially zero detector noise, and is able to record each individual X-ray photon as it strikes detector. By eliminating readout dead-time, imaging system supports continuous scans where goniostat is scanned without stopping between frames. Active area of 200 mm diameter and high spatial resolution allows large protein crystal unit cells to be resolved.
|
 UV Strips and Labels provide visual indication of UV dose.UV Process Supply, Inc.
Chicago, IL 60614-4805
Sep 01, 2005 UV FastCheck™ Strips are used to determine levels of accumulated UV dose via visual inspection of 5 separate color changing zones. Made from same material, UV Intensity Labels operate on same color changing principle but display UV dose accumulation via 1 color changing zone. They measure UV doses from 0 mJ/cm² to greater than 5,000 mJ/cm². Strips measure 2 1/8 x ½ in., while labels measure 1 x ¾ in. |
 Flame Detectors provide high false alarm immunity.General Monitors
Lake Forest, CA 92630
Jul 29, 2005 Microcontroller-based, ATEX-approved UV/IR Model FL3110 and UV Model FL3111 include flicker-discrimination circuitry and self-checking continuous optical path monitoring to ensure fire protection. Both feature segregated wiring compartment where field terminations can be made without exposing ex-proof section to elements. Electronics are integral within stainless steel explosion-proof housing, allowing information to be processed at point of detection. |
 UV Sensor detects presence of fluorescent agents.Keyence Corporation of America
Woodcliff Lake, NJ 07675
Jan 25, 2005 Digital Model CZ-H52 detects materials that are invisible to naked eye, and can not be detected by photoelectric sensors. Unit emits UV light beam from transmitter in sensor head, and receiver picks up visible light reflected by fluorescent materials. Sputtered gold coating on receiver lens eliminates reflections from ambient and stray light. Detection range is 0.98–2.17 in. and minimum beam spot size is 0.39 in. at distance of 0.98 in. from target. |
 UV Sensor aids in control of adhesive dispensing.EMX Industries, Inc.
Cleveland, OH 44128
Dec 30, 2004
With operating distance to 350 mm, UVX-300G UV luminescence sensor detects glue and adhesives in assembly and manufacturing processes. It discriminates targets in any orientation from similarly colored backgrounds and offers 5 user-selectable gain settings and readings from 0-99. Features include adjustable light projection, numerical display of reading intensity, and auto-teach and manual calibration. Feedback response time is rated at 6 kHz.
|
 Flame Detector monitors for hydrocarbon-based fires.MSA
Pittsburgh, PA 15230 0426
Oct 14, 2004 FlameGard® UV/IR Flame Detector detects UV and IR radiation emitted by hydrocarbon-fueled fires and responds by activating relay, which can be part of fire alarm loop or connected to digital control system. Enclosed in heavy duty, copper-free, explosionproof aluminum housing, unit provides stand-alone operation or can be connected to standard 4-wire fire control panels. Optional Air Purge Kit keeps viewing glass clear in dusty environments.
|
(Showing headlines 1 - 17)
|
Latest Products in the News |
PANalytical, Inc. - February 21, 2008 PANalytical at PITTCON 2008
PANalytical, Inc. - January 19, 2008 PANalytical and CERN Collaboration Brings First Commercial Application of Medipix2
More Products in the News...
|
|
|