|
|
Advertisement
|
|
Test & Measuring Instruments ->
Instrumentation I & O Devices ->
Interface Isolation Boards & Modules
Interface Isolation Boards & Modules
(Showing headlines 21 - 40) 1 2 3 4 5 6 7 8 9
|
 Interface Kit digitally controls 8 DPDT relay outputs.Phidgets, Inc.
Calgary, AB T2M3R7 Canada
Feb 19, 2008
Intended for wide range of applications, PhidgetInterfaceKit 0/0/8 allows users to control, from any PC, 8 DPDT relay outputs that are rated at 250 Vac or 2 A, for maximum of 65 W. It has maximum switching voltage of 250 Vac and 220 Vdc, 10 µA wetting current, 10 mV voltage, and quiescent and active current consumption of 14 and 380 mA, respectively. Unit also offers 18 msec operating and releasing time and 20 contacts/minute switching speed at maximum load.
|
 Interface converts PC/laptop into laser power/energy meter.Ophir-Spiricon Inc.
Logan, UT 84321
Jan 30, 2008
Pulsar-4 Multi-Channel Smart Head to PC Interface supports up to 4 smart heads at once using plug and play connectivity. USB interface records pulse energies at up to 20,000 Hz for 4 channels simultaneously and external trigger measures missing or specific pulses. Device is compatible with Ophir thermopile, photodiode, and pyroelectric smart heads. USBI PC software and ActiveX support is standard.
|
Ethernet to Serial Interface remotely controls Modbus RTUs.ICS Electronics Corp.
Pleasanton, CA 94588
Jan 15, 2008
Model 8099 allows temperature chambers and other Modbus-controlled devices to be controlled as VXI-11.3 or LXI instrument over Internet or company network. By providing Modbus RTU packet communication to adapt Modbus slave devices to TCP/IP (Ethernet) network, solution lets user send simple read-write messages over network to control and query slave Modbus devices. Unit is has RS-232 and RS-485 interfaces, performs all Modbus RTU packet formatting, and handles response packets.
|
Single-Chip SpaceWire Interface is radiation-hardened.BAE Systems
Wayne, NJ 07474 0975
Jan 15, 2008
Measuring less than 1E-9 upsets/bit-day SEU, Radiation-Hardened Single-Chip SpaceWire Interface is radiation-hardened to 200 krad (Si) total dose, and is latch-up immune. Chip consists of 4 SpaceWire ports and 2 peripheral component interconnect buses connected by 6-port router, multi-GB memory interface supported by direct memory access controller, and embedded microcontroller for packet processing/standalone operation.
|
 LCD Controller includes text overlay feature.Digital View, Inc.
Morgan Hill, CA 95037
Nov 30, 2007
Model SVH-1920 Advanced HD LCD controller offers text overlay feature that merges video and informational text on single display and enables controller to receive text strings of up to 40 characters. Text sequences are delivered via controller serial port and can be overlaid on up to 4 separate lines at bottom of screen. Text strings can be sent to individual lines, along with horizontal positioning commands, line or screen erasure, and selectable background transparency.
|
 Communication Modules suit self-healing ring applications.Weed Instrument Co., Inc.
Round Rock, TX 78680
Nov 28, 2007
Utilizing Downstream Multicasting technology, EOTec 2C31 and 2C32 are single and dual self-healing ring modules that provide multiple communication paths between various elements of control system. Downstream Multicasting transmits incoming message in multiple directions and insures that, while directing message toward all nodes in ring, it is never retransmitted back to point of origin. Housed in DIN-rail enclosures, fiber optic modules include local and remote diagnostic tools.
|
I/O Module integrates with process automation systems.MYNAH Technologies
Chesterfield, MO 63005
Nov 14, 2007
Allowing users to complete automation migration without having to replace existing PLC I/O systems, PLC I/O Interface supports GE Genius Bus, ModiconS908 Remote I/O, and Allen-Bradley 1771 Remote I/O systems. PLC Explorer Utility facilitates configuration of interface and system migration. Interface uses Modbus TCP/IP protocol for open connectivity to modern control systems and allows I/O access from multiple controllers that support this protocol.
|
 Controller provides interface for transducers.AMETEK Solartron Metrology
Gastonia, NC 19301
Nov 01, 2007
Designed to work with gauging transducers operating on Solartron's Orbit® Network, SI 3500 features menu-driven display that can be programmed to set limits and record other parameters. Powered by 24 Vdc, plug-and-play instrument can display single or multiple transducer readings or computed results, such as A, B, A+B, (A+B)/2, or (A-B)/2, as well as computations with constants. Device features discrete I/O and selection of analog outputs in form of 4-20 mA or dc voltage.
|
Tap Filters allow remote management of network traffic.VSS monitoring, Inc.
Burlingame, CA 94010
Oct 09, 2007
Distributed Network Taps allow users to separate select traffic from monitoring stream to provide analyzers with packets of interest only. Filter Options include MAC source/destination; IP address/range; UDP & TCP port/range; VLAN/QoS; and IP type-of-service, including any protocol of known port ranges. User can configure multiple filters per tap port using HTTP or command line interface where each filter can be set to PASS or DROP traffic selection.
|
I/O Station links adjustable frequency drives to networks.TURCK, Inc.
Plymouth, MN 55441
Sep 24, 2007
DeviceNet(TM) Drive Interface station is designed to interface adjustable frequency drives onto DeviceNet network and can support up to 4 standalone adjustable drives on network. Housing is constructed of glass-filled nylon that provides IP 20 protection rating. Station connects to DeviceNet via 5-pin removable screw terminal connector and 12 relay outputs, 4 digital inputs, and 4 analog outputs are available on screw terminal connectors.
|
 DAQ/Strain Gage Interface Board suits embedded applications.Electro Standards Laboratories
Cranston, RI 02921 3403
Sep 12, 2007
Supporting high speed analog and digital data acquisition, CellMite ProD Model 4333 features dual 24-bit independent strain gage channels with simultaneous sampling of 15 kS/sec that can also be configured as quad 24-bit strain gage channels sampled at 5 kS/sec. It also features twelve 12-bit analog input channels with throughput of 1 MS/sec, four 16-bit analog output channels with user-specified scaling and offset with range of ±10 V. Digital inputs can be sampled at 20 MS/sec.
|
 Interface Module provides battery/power supply protection.Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Aug 16, 2007
Used as protective interface between battery and power supply, XCSBC Battery Charger Interface Module is rated for power supplies from 1-10 A. It is mainly used for DC backup so that battery acts as backup in case of power failure and power supply provides trickle-charge for battery to remain fresh. Occupying 1 in. of space on DIN rail, module features protection diodes, charging current limiting resistor, and protection fuses for battery.
|
 Universal Controller aids continuous flow isotope ratio MS.Thermo Fisher Scientific
Waltham, MA 02454
Jul 19, 2007
Designed for GC, LC, and elemental analyzers coupled with isotope ratio mass spectrometers, ConFlo IV Universal Interface enables immediate switching between up to 3 sample preparation devices. It includes smartEA(TM) mode, which allows automated pre-evaluation and adjustment of sample gas intensities. Along with flexible, computer controlled auto-dilution of sample and reference gases, software also controls stand-by and start-up of Thermo Scientific TRACE GC and Flash EA modes.
|
Line Interface Unit suits high-density applications.Exar Corp.
Fremont, CA 94538
Jul 19, 2007
Providing relay-less board hot swapping, 16-channel T1/E1/J1 Model XRT83VSH316 features selectable RX and TX internal terminations for 75/120, 100, and 110 W lines. Unit has master clock timing generator where only single T1, E1, or 8 kHz clock is needed. Additional features include system side RLOS, AIS, QRSS/PRBS generation/detection; line side RLOS, AIS, QRSS/PRBS generation/detection; DMO with 16-bit LCV counters; and diagnostic loop back modes for each channel.
|
Interface Boards facilitate host-based media processing.Pika Technologies Inc.
Kanata, ON K2M2V8 Canada
Jul 10, 2007
With PCIe version of Digital T1/E1 Gateway trunk board and PCIe Analog Station Board, developers can design IP-centric applications that support shift to IP but allow for gradual migration that will incorporate mix of VoIP and TDM technologies. Trunk board supports up to four T1 or E1 spans, configurable in single span increments, while Analog Station Board supports connection of up to 12 ports for traditional analog telephone devices. Both conform to 9.5 in. PCIe form factor.
|
Starter Kit adds wireless connectivity to applications.Jennic Ltd
Sheffield United Kingdom
Jul 02, 2007
With Starter Kit, developers with little or no RF design experience can add IEEE802.15.5 and ZigBee wireless connectivity to their products. Three hardware nodes, based on JN5139 wireless microcontroller modules, allow users to evaluate and develop wireless sensor network applications. Serial API can be used, either embedded with application or via serial or SPI ports to external microcontroller. Nine-pin RS232 connector is supplied for interface to PCs and industrial equipment.
|
Interface Module simplifies RJ/wired conections.Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Jun 21, 2007
Available in both RJ-11 and RJ-45 types in 4, 6, and 8 position, Modular Jack RJ Interface Module provides means of interfacing between various types of equipment that use Ethernet/RJ type of connectors and individual wiring. Each module features rugged modular DIN rail base with clearly ink-marked terminal blocks that help simplify wiring.
|
Line Interface Units feature 8-channel operation.Exar Corp.
Fremont, CA 94538
Jun 20, 2007
Models XRT83VSH38 and XRT83VSH28 8-channel LIUs offer power down mode with
independent receive and transmit selection, onchip transmit short circuit protection, and selectable crystal-less digital jitter attenuator with 32-bit or 64-bit FIFO. Model XRT83VSH38 for T1/E1/J1 applications also features selectable RX and TX internal terminations (T1/E1/J1) for 75/120, 100, and 110 W lines. Model XRT83VSH28 is aimed at E1 only environments.
|
 Ethernet-to-Digital Interface Board provides 48 digital I/O.ICS Electronics Corp.
Pleasanton, CA 94588
Jun 14, 2007
Designed to control digital devices over company network or Internet, Model 8063 Ethernet-to-Parallel Interface offers 48 parallel I/O lines that can be configured as inputs or outputs in 8-bit bytes. Unit can monitor 15 input lines and generate VXI-11 Service Request messages when enabled line changes state. Handshake lines are provided for synchronizing data transfers or for latching data into external devices. Compliant with RoHS, device is housed in rack mounted Minibox case.
|
Inteface monitors and controls I/O of HVAC drives.ABB Automation
New Berlin, WI 53151
May 11, 2007
RLON-01 LonWorks interface for ACH550 series variable frequency drive supports pass-through I/O, allowing integrators to use drive's digital inputs and outputs as free I/O points in system. Points can be used for monitoring and control of external devices that may or may not be related to VFD HVAC application. Uses include ability to monitor inputs and outputs, command outputs, and monitor hand/auto status, voltage, or drive last fault.
|
(Showing headlines 21 - 40) 1 2 3 4 5 6 7 8 9
|
|
|