 PMC I/O Module utilizes reconfigurable Virtex-5 FPGAs.Acromag, Inc.
Wixom, MI 48393 7037
Feb 22, 2008
PMC-VLX modules feature logic-optimized Xilinx® Virtex(TM)-5 FPGA that is reconfigurable for high-performance I/O processing and custom logic routines. Two banks of 32 Mb x 16-bit DDR2 SDRAM receive data from I/O ports for FPGA processing; processed data moves to 2 banks of 256 Kb x 32-bit dual-ported SRAM for high-speed DMA transfer to PCI bus. PMC base card is ready for use in conduction-cooled systems and provides 64 LVDS I/O channels accessible via P4 rear connectors.
|
I/O Cubes target Simulink users.United Electronic Industries
Canton, MA 02021
Feb 15, 2008
Suited for Simulink users who need to test their simulations on real hardware, UEISIM facilitates creation and tuning of wide variety of applications, including simulation model verification, rapid prototyping, and hardware-in-the-loop testing. Model UEISIM 300 allows installation of up to 3 I/O boards, while Model UEISIM 600 allows installation of up to 6 I/O boards (containing up to 150 analog inputs or 288 DIO), and measures 4 x 4.1 x 5.8 in.
|
 Module measures up to 10 analog inputs.Axiomatic Technologies Corp.
Mississauga, ON L4W2Z3 Canada
Feb 14, 2008
Designed to communicate data to CAN network, Model AX030100 offers 10 user-selectable inputs including 0-5 V, 0-20 mA, and 4-20 mA for connection to variety of analog machine sensors or levers. User can also select multiple PWM inputs, frequency, counter, or active high digital input. Accepting nominal power input of 12, 24, 42, 48, or 72 Vdc, module features IP67-rated packaging suitable for applications in harsh environment of mobile equipment with on-board battery power.
|
Mezzanine Cards use FPGAs for various I/O combinations.Men Micro Inc.
Lago Vista, TX 78645-4160
Jan 17, 2008
Based on Cyclone FPGAs, Universal Submodule concept is available in P699 XMC and P598 conduction-cooled PMC models. Model P699 uses Cyclone III FPGA with 24,624 logic elements and 4 MB Flash memory, while Model P598 features Cyclone II with 33,216 logic elements and 2 MB flash. Nios soft core processor, which features 32 MB of DDR2 SDRAM main memory, is implemented on FPGA. Different IP cores allow user to change functionality of either card without hardware modifications to main module.
|
I/O Card uses 1 M or 1.5 M gate Xilinx FPGA for all logic.Mesa Electronics
Richmond, CA 94806-1950
Jan 03, 2008
Featuring four 50-pin connectors with I/O module rack compatible pin-outs and interleaved grounds, Model 5I22 enables creation of any kind of specialized I/O function. Each connector provides 24 I/O bits for total of 96 programmable I/O bits that are 5 V tolerant and can sink 12 mA. Bus master and DMA capability optimize PCI transfer rates, while 48 MHz crystal oscillator provides reference clock, which can be multiplied by FPGAs DLLs for higher clock speeds.
|
 Analog Input Card features 32 channels.Advantech Automation Corp.
Cincinnati, OH 45240
Dec 20, 2007
With isolated circuits, Model PCI-1715U protects sensitive measurement circuitry from interference currents or voltages, which is useful when external voltage is different that expected by measurement hardware. Unit offers sampling rate up to 500 kS/s, 12-bit resolution, and isolation protection of 2,500 Vdc. Providing programmable gain for each input channel, card includes 1,024 samples FIFO buffer and supports internal and external pacer sampling modes.
|
 Modules offer optical coupler/splitter/WDM functionality.M2 Optics, Inc.
Holly Springs, NC 27540
Dec 19, 2007
M2 FiberSplit(TM) Micro Modules feature 2U packages allowing 20 single width passive optical modules to fit into 19 in. rack. At 5.1 x 0.7 in. and 2U high, modules are available in 1 x 2 through 1 x 8 splitters as well as in CWDM and DWDM configurations. They are also available in combinations operating in 1,310 nm, S, C, and L bands. Applications include telecom, Passive Optical Networks (PON), LAN, CATV, and data distribution centers.
|
RFID Module suits IP20 cabinet or IP67 field installations.TURCK, Inc.
Plymouth, MN 55441
Dec 17, 2007
Complimenting BL20 and BL67 network I/O systems, 2RFID Module enables up to 8 channels to be added to single BL ident code, depending on system requirements. All channels operate in parallel so there is no time delay during communication between data carrier and module. Additionally, 32 kByte memory allows asynchronous processing of individual read/write commands, while LEDs display diagnostics for RFID channels and fieldbus-specific diagnostic messages.
|
 Serial I/O Copper Link eliminates data traffic congestion.FCI
Etters, PA 17319
Dec 11, 2007
Suited for linking servers, storage, computers, switches, and other data network or communications devices, EyeMax(TM) 4X and 12X serial I/O copper link enables continuous flow of high-speed data transfers at greater than 2.5 Gbps per link/channel for cable lengths up to 10 m. RoHS-compliant unit also offers less than 4% cross-talk performance to support switched fabric link capabilities and scalability within and between system hardware applications.
|
I/O Module enables in-chassis analysis of protocol traffic.LeCroy Corp.
Chestnut Ridge, NY 10977
Dec 07, 2007
Designed for PETracer(TM) PCI Express Protocol Analyzer series, ExpressModule(TM) Interposer helps analyze traffic between ExpressModules and their respective host systems by decreasing probing setup times. PCI Express-based solution inserts into back of server backplane and promotes RAS capability in server systems. It minimizes signal interference by using passive tapping, allowing protocol traffic between ExpressModule and backplane to be analyzed while inside chassis.
|
Ethernet Modules interface 16 discrete I/O.Acromag, Inc.
Wixom, MI 48393 7037
Dec 06, 2007
Providing eight 32-bit pulse counters with timers, alarms, and non-volatile memory, BusWorks® 989EN Modules deliver isolated Ethernet Modbus TCI/IP interface for any I/O mix of up to 16 discrete signals. Commercial and industrial-grade inch-wide units have 16 individually configurable bi-directional I/O channels with 0-28 Vdc signal range. When configured as inputs, channels accept 2- or 3-wire sensors and active logic switches for use with dry contacts, proximity, namur, or 5-28 Vdc logic.
|
Analog Input Module provides precise data acquisition.Men Micro Inc.
Lago Vista, TX 78645-4160
Nov 27, 2007
Available in 16- or 18-bit versions, M36N M-Module provides data acquisition for automation, measuring, and simulation applications. It can be used as I/O extension for CompactPCI, PCI, PXI, or VME embedded systems as well as on standalone SBCs. Module provides up to 16 single-pole grounded channels for voltage or current, or 8 channels for differential voltage or current. ADC and automatic increments of multiplexer channel enable total acquisition time of 130 µsec for full 16 bits.
|
Remote I/O Units integrate with SCADA systems.Audon Electronics
Nottingham NG9 4AT United Kingdom
Nov 26, 2007
Suited for data acquisition and distributed control applications, Modbus-based I/O units integrate analog/digital signals to supervisory SCADA systems. Digital I/O modules include model 16DI with 16 digital inputs, model 16DO with 16 open collector transistor outputs, model 4RO with 4 mains capable power relays, and model 8DIO with 8 digital inputs and 8 transistor outputs. Analog I/O modules include models 8AIIS and 8VIS that accept 8 x 4 20 mA or voltage inputs.
|
I/O Module integrates with process automation systems.MYNAH Technologies
Chesterfield, MO 63005
Nov 14, 2007
Allowing users to complete automation migration without having to replace existing PLC I/O systems, PLC I/O Interface supports GE Genius Bus, ModiconS908 Remote I/O, and Allen-Bradley 1771 Remote I/O systems. PLC Explorer Utility facilitates configuration of interface and system migration. Interface uses Modbus TCP/IP protocol for open connectivity to modern control systems and allows I/O access from multiple controllers that support this protocol.
|
Digital Instrument can test LRU and SRU assemblies.Geotest - Marvin Test Systems, Inc.
Irvine, CA 92614-5846
Nov 13, 2007
Suited for testing complex digital products, Model GX5055 6U PXI digital I/O instrument offers I/O voltage range of 10 to +15 V with full 25 V swing, per pin programmable drive, sense, and load capabilities, as well as deskew per pin and 50 MHz vector rate. Unit is designed to address broad range of Mil/Aero digital test applications at both factory and depot level.
|
I/O Blocks facilitate design of DeviceNet networks.Balluff, Inc.
Florence, KY 41042-0937
Nov 05, 2007
ODVA-approved connectivity products include 4 machine-mount DeviceNet(TM) I/O modules, available in 16 input-only, 16 point-configurable, 8-input/8-output, and 8 output-only models, that allow design and construction of virtually any DeviceNet network. Each has status LEDs; high-density inputs that enable use of splitters to double input count; and full-metal, low-profile housing that survives rough treatment and keeps cables protected.
|
 Digital I/O Boards assemble PCI and compact PCI test systems.ICSDataCom
Pleasanton, CA 94588
Nov 01, 2007
Including Models ME8200A, ME8200B, ME8200AC, and ME8200BC, Series ME8200 cards provide 16 isolated outputs, 16 isolated inputs, and 16 general purpose TTL lines. Isolated outputs can drive 3-45 V loads and source up to 700 mA per channel, while 16 isolated inputs accept inputs from 3.3-45 V and incorporate transient protection. General purpose TTL lines are 2 bidirectional 8-bit ports, and can be independently used as latched outputs or as gated inputs.
|
Analog Input Station features IP67 rating.TURCK, Inc.
Plymouth, MN 55441
Oct 29, 2007
Featuring fiberglass-reinforced nylon housing and full epoxy encapsulated electronics, Analog Input Station supports 4 analog inputs on DeviceNet(TM) network. Inputs may be configured for either analog current from 0-20 mA or 4-20 mA, or analog voltage from 0-10 V or -10 to 10 V. Capable of on-machine installation in harsh environmental conditions, station uses rotary switch or DeviceNet software for configuration.
|
 I/O Modules interface to low/high voltage peripherals.Mosaic Industries
Newark, CA 94560
Oct 26, 2007
Featuring 4 dedicated digital inputs and up to 16 more channels that can be configured for either input or output, Digital I/O Wildcard adds programmable digital I/O to controller. Each I/O line is configured for pull-up, pull-down, or tri-state operation. Power I/O Wildcard can be used to interface high-voltage peripherals to instrument or to drive stepper motor, and offers 8 high-current outputs and 4 high-voltage digital inputs. Inputs and outputs are optically isolated to ±2,500 V.
|
Data Acquisition Board includes arbitrary waveform generator.ACCES I/O Products, Inc.
San Diego, CA 92121 1506
Oct 22, 2007
Suited for any PC/embedded system with USB port in rugged industrial environments, Model USB-DA12-8A measures 3.550 x 3.775 in., and features 8 independent 12-bit DACs, 32-bit counter, 128K sample buffer on-board, and DIN rail mounting provision. Other features include 0-2.5, 0-5, 0-10, ±2.5, ±5, and ±10 V output ranges, single-ended and differential outputs for noise immunity, ARB status and control signals via external connections, and two DB25 industry-standard connectors.
|