Other Indicators

Test & Measuring Instruments, Sensors, Monitors & Transducers, Communication Systems & Equipment

Circuit Breaker Finder performs multiple functions.

November 7, 2014

Comprising transmitter and receiver, BF20 Circuit Breaker Finder with NCV Detector and GFCI Outlet Checker determines circuit breaker or fuse associated with any 110 V outlet without interrupting power. Fully automatic unit also detects energized lines, cables, and outlets; tests for and identifies common outlet wiring faults; and verifies operation of GFCI circuits. Designed to comply with safety standard IEC 61010-1, instrument includes circuit that eliminates false positives. Read More

Test & Measuring Instruments

Dual Display Digital Indicator accepts range of input signals.

October 14, 2014

Featuring dual display with tri-color and variable-intensity digits, 2200 Series accepts variety of input signals – thermocouples or RTDs, current, voltage, resistance, and process signals – and offers meter update rate of up to 160/sec and 24 Vdc sensor excitation. Universal power input accepts AC or DC voltage, built-in USB port allows configuration via computer, and plug-in option cards are available for field upgrades. Interface software is also available. Read More

Test & Measuring Instruments, Controls & Controllers, Sensors, Monitors & Transducers

Pressure Controller monitors gas supply pressure.

October 7, 2014

Used for monitoring gas supply pressure from 1 or 2 pressure switches with single or dual outputs, GigaGuard™ Pressure Status Indicator (PSI) comes in 8.0 x 2.5 x 4.25 in., NEMA-rated, ABS plastic enclosure with brackets for wall/rack mounting. Configuration may be accessed and adjusted via any Web-compatible browser, and indicator lights and audible alarm signify pressure conditions that exceed user-specified set points. Communications are supported via MODBUS TCP or Ethernet RJ45 port. Read More

Test & Measuring Instruments, HVAC, Sensors, Monitors & Transducers

Refurbished/Replacement TCDs are available for legacy Varian GCs.

August 14, 2014

Refurbished or replacement thermal conductivity detectors (TCDs) are available for Bruker (Varian) gas chromatographs (GCs). Each detector, made of stainless steel and supplied with rhenium-tungsten (WX) filaments as standard, meets original equipment specifications and comes ready to install in legacy Varian GC. Special filaments for reactive samples are available. Corrosion-resistant detectors utilizing nickel, Monel®, titanium or gold-plated thermal conductivity blocks are also offered. Read More

Test & Measuring Instruments, Controls & Controllers, Sensors, Monitors & Transducers

Single Float Level Transmitters suit shallow tank monitoring.

July 16, 2014

As drop-in replacements using existing tank fittings, XM/XT Series provide continuous fluid level monitoring of tanks with depths <20 in. XM/XT-300 Series, constructed from all-wetted polysulfone plastic parts, is direct compatibility with various chemicals, while XM/XT 700 Series comes in stainless steel or brass. Both fluid level transmitters feature 0.14 in. resolution, indicating length to 14 in., and stem length to 20 in. Custom mountings and float materials are available. Read More

Test & Measuring Instruments, Controls & Controllers, Sensors, Monitors & Transducers, Electronic Components & Devices

Conductivity Sensor integrates into inline systems.

July 2, 2014

Suited for cooling tower monitoring and other processing environments, CS8000TC electrode has conductivity cell constant of k=1.0 ±10% for wide measurement range within its temperature/pressure of 60°C/100 psig. Temperature compensation is included with choice of 4 sensor types: 10K, 30K NTC, Pt100, and Pt1000 RTD. Keyed flange facilitates sensor orientation, detachable cable assembly negates need to pull cable through conduit, and sensors can be removed without tools for cleaning/calibration. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Remote Sensor Monitoring Devices log data and send notifications.

June 2, 2014

Used for remote monitoring over Ethernet, Poseidon2 3266/3268 can log measured data; monitor temperature, humidity, or voltage; and monitor detector states (DI inputs) and up to 8 other external sensors and 4 detectors. Alarm emails can be sent if values venture outside set safe range. Also able to connect to other monitoring systems, devices can send alarm SMS messages through shared HWg-SMS-GW. Poseidon2 3268 has 2 relay outputs for setting other devices. Read More

Safety & Security Equipment, Test & Measuring Instruments, Transportation Industry Products, Vision Systems, Computer Hardware & Peripherals, Mechanical Components & Assemblies, Electrical Equipment & Systems, Sensors, Monitors & Transducers, Mechanical Power Transmission, Electronic Components & Devices, Green & Clean, Display & Presentation Equipment

Flashing Dome LED Beacon Lights suit AC or DC applications.

April 10, 2014

Offering IP23 protection and vibration resistance, Models XPE and XME provide brightly colored triple-flash sequence that illuminates at 110 flashes/min, making them suited for indoor mobile equipment. XPE model measures 162 mm dia x 203 mm tall and has high-impact, heat-resistant ABS resin body, while XME version, made of stainless steel with melamine baked finish, is 187 mm in dia x 239 mm tall. Typical current consumption ranges from 0.07 A for 230 Vac models to 0.42 A for 12 Vdc models. Read More