Test & Measuring Instruments ->
Indicators ->
Current or Voltage Indicators
Current or Voltage Indicators
(Showing headlines 1 - 20) more ....
|
 Power Monitor Module enables channel-specific diagnosis.Siemens AG
Munich D-80333 Germany
Apr 17, 2012
Complimenting all 24 V power supplies, Sitop PSE200U distributes and monitors load current across several load feeders. Overloading and short circuits are displayed on separate LED for disconnected channel. Channel-specific signalling - indication of faulty 24 V load circuit - is available in selectivity modules with outputs of either 4 x 3 A or 4 x 10 A. To enable channel-specific analysis, message output is connected to controller's digital input.
|
 Battery Monitoring IC extends battery life of handhelds.STMicroelectronics
Lexington, MA 02421
Jan 23, 2012
Supplied in 2 x 3 x 0.8 mm package, STC3105 measures battery voltage and current to increase handheld electronics' battery runtime and lifespan. IC uses open-circuit voltage and coulomb-counter methods to estimate battery capacity as well as supervise and track charge/discharge status. Drawing 60 µA typ, product also features power-saving mode and programmable alarm output. Latter can alert system when battery state of charge is below certain level without involving system MCU.
|
 Wide-Band High Current Transformer has 30 cm OD and 15 cm ID.Ion Physics Corp.
Fremont, NH 03044
Feb 10, 2011
Electrostatically shielded CM-01-CS11 measures narrow current pulse of several hundred kA and AC currents up to 2,000 ARMS with 3 dB bandwidth of 0.1 Hz to 100 kHz. One turn primary is internally terminated in low inductance impedance network to convert current signal to voltage signal. Offering 1 mV/A sensitivity, monitor senses magnetic field surrounding primary current carrying cable or charged particle stream. Saturation limit is 250 A, usable risetime is 4 µsec, and droop is 0.1%/ms.
|
 USB AC Monitor and Relay replaces PC-based plug-in cards.J-Works, Inc.
Sylmar, CA 91342
Feb 03, 2011
Used in test, control, monitoring, and measurement applications, model JSB375 monitors 4 AC lines and features four 15 A, SPST relays. AC monitor inputs sense AC voltage, and current state of each input can be read from USB port. SPST relays outputs provide host control between common line and normally open connection point. In addition to supporting 2 or 4 monitors and relays, product accommodates any programming or test language that supports USB communications.
|
Medium Voltage Indicator uses capacitive coupling, earth ground.Grace Engineered Products, Inc.
Davenport, IA 52807
Sep 27, 2010
Respectively suited for 2-15 kV and 15-43 kV applications, VoltageVision® R-1VH and R1VL provide safety for workers performing mechanical or electrical maintenance on medium voltage equipment by helping to ensure isolation of electrical energy. Products utilize capacitive coupling with earth ground to complete flashing circuit as well as provide surge immunity and electrical installation integrity. Amount of energy transferred to indicator determines flash rate and intensity.
|
Power Monitoring System cuts data center power consumption.2BM Ltd
Nottingham NG9 6DZ United Kingdom
Sep 09, 2010
Able to be installed into live environments for uninterrupted operation, 2bm iMeter features intelliAmp sensor, which monitors current draw of racks via 16 and 32 A cables. System provides insight into energy requirements of servers, SANs, switches, and attendant supporting equipment, enabling controlled reduction of data center's PUE rating. In addition to continuous voltage and current monitoring, system offers True-RMS current metering, user-configurable alarm thresholds, and Web interface.
|
 MaterialsTesting System characterizes electrical materials.AMETEK Solartron Metrology
Gastonia, NC 28054
Aug 13, 2010
Designed to test electrical properties of materials ranging from insulators to superconductors, ModuLab MTS combines time domain tests and AC tests together with wide range of modules, providing high voltage, high current, resolution, and sample/reference measurements. Core of system is MAT core module, which makes use of DSP technology to provide accurate experiment control, data acquisition, data averaging, and responsive safety and step limit detection.
|
Automation Control System offers safe processing of analog values.Pilz Automation Safety L.P.
Canton, MI 48187
Jun 08, 2010
With failsafe analog input modules, PSS 4000 is suitable for safe, decentralized recording of analog values. Two different modules are available for safety-related evaluation of voltage signals from -10 to +10 V or current signals from 0-25 mA. PSSuniversal PLC offers various head modules to which I/O modules can be connected individually and which are available for control functions, local preprocessing, or in form of communication interface for SafetyNET p.
|
High-Voltage, High-Side Current Monitors offer 40 and 60 V operation.Diodes, Inc.
Westlake Village, CA 91362
Jun 07, 2010
Models ZXCT1083, ZXCT1085, and ZXCT1087 support voltage range of 2.7-40 V, while ZXCT1082, ZXCT1084, and ZXCT1086 units are rated for 2.7-60 V. Products detect current in high-side sense resistor and reference it to ground. Featuring independent supply and common-mode voltage inputs, ICs permit currents to be measured beyond limits of normal power supply rails. They operate over -40 to +125ºC temperature range, with quiescent current of 0.6 μA, and offer fixed and programmable gain.
|
Voltage and Current Monitor targets grid-connected systems.austriamicrosystems AG
Premstatten Austria
May 25, 2010
Housed in 4 x 4 mm QFN-16 package, Model AS8002 delivers sensed voltage and current in high-resolution digital format and is intended for grid connected systems such as solar photovoltaic inverters. Flexible front-end provides adjustable gain to accommodate various resistor values, while on-chip calibration allows compensation for external component inaccuracies and variations over temperature. Operating from 3.0-3.6 V, IC is specified for temperature range of -40 to +125°C.
|
Dual Voltage Phase Monitor covers 200-240, 425-525 Vac ranges.Motor Protection Electronics, Inc.
Apopka, FL 32703
May 25, 2010
Featuring dual adjustment ranges, Model 001-DVM-118 monitors for under voltage, phase reversal, and phase imbalance. Plug-in, 8-pin unit has one SPST output relay rated 10 A @ 240 Vac and one additional NO contact between pins 6 and 7. This additional contact carries same rating and closes as well when correct voltage is supplied. With correct voltage applied, internal relays will energize and LED illuminates, allowing normal operation.
|
12-Pin Phase Monitor offers dual adjustment ranges.Motor Protection Electronics, Inc.
Apopka, FL 32703
May 25, 2010
With adjustment ranges of 200-240 or 425-525 Vac, 12-pin Model 001-DVM-1212 monitors for under voltage, phase reversal, and phase imbalance. Plug-in style unit has one DPDT output relay rated 10 A at 240 Vac. With correct voltage applied, internal relay energizes and LED illuminates, allowing normal operation. Abnormal condition causes LED to blink during trip delay, and when trip delay has expired, internal relay will be de-energized. LED then provides pulses that indicate fault condition.
|
 Quad-Voltage Supervisor conserves energy and board space.ON Semiconductor, LLC
Phoenix, AZ 85008
Apr 26, 2010
Integrating 4 voltage level monitors in RoHS-compliant, 6-pin SOT23 package, CAT8710 is suited for simultaneously monitoring multiple voltages in microprocessor- or ASIC-based systems. There are 2 factory preset thresholds for monitoring 3.3, 3.0, 2.5, and 1.8 V supplies within ±5% and 2 that are customer-programmable using external resistors and adjustable down to 0.6 V. While product can be operated from 1.5-5.5 V supply, it only draws 3 µA.
|
 APD Current Monitor reduces settling time for GPON modules.Maxim Integrated Products
Sunnyvale, CA 94086
Apr 05, 2010
Supplied in 3 x 3 mm, 14-pin TDFN package with exposed pad, DS1842A is 76 V APD (avalanche photo diode), bias-output-stage, and current-monitoring IC suited for providing bias to and current monitoring for APDs in PON-OLT and PON-ONT equipment. It integrates high-voltage current source; several current mirrors for monitoring APD current; and FET switch configured to work in conjunction with external DC-DC controller to implement boost DC-DC converter.
|
 Multichannel System Monitors have highly integrated design.Maxim Integrated Products
Sunnyvale, CA 94086
Mar 16, 2010
Designed to simplify power-management schemes in multivoltage systems, flash-configurable MAX16070/MAX16071 supervise 12/8 voltages plus one current. Each integrates current monitor, nonvolatile fault registers, and graphical configuration tool. In addition to ±1% accurate voltage monitoring, products offer ±2.5% accurate current monitor that eliminates need for external current-sense amplifier. Specified over -40 to +85°C range, ICs come in 6 x 6 mm, 40-pin TQFN package.
|
 Three-Phase Energy Meter delivers robust multifunctionality.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Feb 23, 2010
General-purpose EM21 Series features detachable, connector-less, and battery-less LCD that lets user configure instrument for panel or DIN-rail mounting as energy meter or transducer. It is suitable for active and reactive energy metering for cost allocation as well as main electrical parameter measurement and retransmission. Solution supports single-phase (2-wire), 2-phase (3-wire), 3-phase (3-, 4-wire, balanced, unbalanced) systems for up to 400 VLL.
|
 Dual Voltage/Phase Monitors deliver diverse protection.Motor Protection Electronics, Inc.
Apopka, FL 32703
Feb 15, 2010
Dual Voltage Phase Monitors, available in 2 plug-in styles, are auto-ranging units that protect against under voltage, phase reversal, phase loss, and phase imbalance. Options include over voltage protection and 5 Delay on Operate time delays. Acting as diagnostic tool, 8-pin 001-DVM-118 and 12-pin 001-DVM-1212 use LED to provide series of pulses that indicate which fault is present. Eight-pin version offers additional SPST contact on previously unused pins 6 and 7.
|
Transducers provide DC current monitoring.American Aerospace Controls, Inc. (AAC)
Farmingdale, NY 11735
Aug 25, 2009
Available for differential and ground fault current monitoring, space flight Series S 767 and military grade Series 913 B provide isolated analog output directly proportional to input magnetically. Featuring ½ in. aperture, Series S 767 operates on 22-36 Vdc power with response time of 50 ms. Series 913 B, designed with ¾ in. aperture, operates from 24-32 Vdc power with response time of 1 ms. Both chassis-mount series feature 0 to +5 V output and accuracy of 1% FS.
|
 AC Current Detectors come in clamp-on and pass-thru models.American Aerospace Controls, Inc. (AAC)
Farmingdale, NY 11735
Jul 16, 2009
Designed to compare AC input to fixed or adjustable current threshold, Series 870 and ACS-3 provide isolated switch or relay output that is activated as required. Housed in metal case and operating from -20 to +71°C, Series 870 features SPDT relay output with 10 A contacts, frequency from 47-63 Hz, and ¾ in. dia aperture. Series ACS-3, operating from -50 to +65°C, is housed in plastic case with solid state switch output, frequency from 6-100 Hz, and response time of 200 msec.
|
 Dynamic Current Loggers provide 8,000 samples/sec.Saelig Co., Inc.
Pittsford, NY 14534
Jun 12, 2009
Designed for current and voltage measurements in automotive hybrid or electrical powertrain systems, KLARI-MOD SC 1000V Series offer 16-bit resolution and 1,000 V safety isolation between measurement circuitry and data output. Modules can be adapted to meet changing measurement requirements via use of different shunts or voltage probes. Data output is available via CANbus or RS232 serial interface.
|
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
HD Electric Co. - February 1, 2012 DVI Digital Voltage Indicators
Electro Static Technology - November 4, 2011 New Kit Measures Motor Shaft Voltage to Determine Vulnerability of VFD-Controlled Motors
More Products in the News...
|
|
|