Corrosion Indicators

Test & Measuring Instruments, Sensors, Monitors & Transducers

Dual Linear Array Probe provides corrosion imaging.

February 23, 2015

Adding entry-level inspection capability to existing Olympus HydroFORM® and RexoFORM corrosion solutions, Dual Linear Array™ Probe helps optimize inspection of internally corroded parts such as pipes, tanks, and plates. Phased array solution offers features such as large beam coverage, accelerated scan speed, and C-scan imaging with increased data-point density. Aluminum housing facilitates handling and operation while carbide wear plates protect wedges for durability. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Services

Corrosion Testing is available globally via two laboratories.

October 20, 2014

Equipped with Q-FOG CRH cyclic corrosion tester, laboratories in Homestead, FL and Saarbrücken, Germany offer contract testing services for global customers for automotive corrosion tests requiring RH control. Available tests include GMW 14872 and SAE J2334 as well as others from Ford, ISO, GB/T, VW, Volvo, Chrysler, and Renault. Testers can also perform traditional salt spray and Prohesion® and meet international and automotive corrosion test standards. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Metals Testing System identifies wear and corrosion.

August 28, 2014

When placed on chemically treated test medium, one drop from Acustrip Metals Test® identifies presence and degree (ppm) of metals associated with wear and corrosion – copper, iron, and nickel – within 1 min.  Each metal has its own section on test medium, and regular use lets technicians and operators trend wear on engines and equipment component parts; abnormal presence of metals would lead to immediate corrective action. Product is designed for field use. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Cyclic Corrosion Testers include relative humidity control.

April 3, 2014

Available in both 600 and 1,100 L sizes, Q-FOG® CRH Testers can perform traditional salt spray and prohesion, and meet most major international and automotive corrosion test standards. Units feature RH control through use of air pre-conditioner. In addition to atomized mist salt fog, testers include optional shower function, where spray droplets are much bigger and flow rates are much higher. Advanced cleaning feature for spray nozzles prevents clogging frequently found in competitive chambers. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Flaw Detector uses corrosion inspection software.

September 5, 2013

Available with portable EPOCH 600 Ultrasonic Flaw Detector, Corrosion Module includes automatic ultrasonic setups based on transducer selection, Automatic Gain Control, thickness gage measurement algorithm, V-Path correction, and transducer wear compensation using automatic zero function. Module also features corrosion-style data logger file types, color-coded Grid View, and timed B-scan view for fast data collection and consolidated reporting of areas of interest. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Communication Systems & Equipment

Wireless Corrosion Transmitter works with water systems.

October 12, 2012

Measuring corrosion rate and pitting tendency, Corrater® CWT-9020 is designed for on-line monitoring of water systems in electrically hazardous areas with operating range of -40 to +70°C. Transmitter can be supplied as part of Cosasco® Wireless Corrosion Monitoring System or added to any Emerson Smart Wireless Network or output from gateway via Modbus Interface to any process automation system. Once installed, computed corrosion rate and pitting tendency may be read. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Corrosion Under Insulation Sensors are offered in 3 types.

June 15, 2012

Used to detect corrosion under insulation, Cosasco CUI sensors fit in with any plant integrity management program. Continuous Insulated Braid (corrosion fuse) Wire, Inserted corrosion fuse probe array, and CUI Corrosometer® Probe all offer direct corrosion detection and may be customized to meet individual requirements and applications. Facilitating installation, inserted corrosion fuse probe array and CUI Corrosometer® Probe do not require removal of insulation. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Corrosion Sensors detect corrosion under insulation.

May 23, 2012

Offered in 3 types, CUI Corrosion Monitoring Sensors may be customized to meet requirements. Continuous Insulated Braid Wire Sensor, using insulated carbon steel wire as corrosion fuse, detects corrosion over large area. Inserted Probe Array Sensor acts as corrosion fuse detector that provides indication of corrosion occurring at pipe surface. Consisting of individual electrical resistance probe, CUI Corrosometer® Probe measures corrosion rate near pipe surface and helps determine underlying cause. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Mining, Oil Drilling & Refining

Corrosion Monitoring Tool targets downhole environments.

November 22, 2011

Constructed of corrosion-resistant 17-4 PH SS, DCMS(TM) uses Corrosometer® electrical resistance corrosion probe element to determine rate of metal loss within downhole tubing. Tubular electronic instrument automatically reads and records corrosion probe at regular user-defined intervals. Upon retrieval of Downhole tool, corrosion rate history is downloaded to PC via Corrdata® II Software. Designed to withstand temperatures to 302°F and pressures to 10,000 psi, unit offers 90-day battery life. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Inspection System provides semi-automated corrosion mapping.

July 13, 2010

Comprised of OmniScan MX PA flaw detector, OmniScan MXU software with corrosion mapping, and HydroFORM Phased Array Probe Carrier with Mini-Wheel encoder, HydroFORM System provides non-destructive testing of metal plates, pipes, and welded components for detection of internal corrosion, mid-wall anomalies, and environmentally damage mechanisms. Phased array probes cover area up to 2.36 in. wide at speed of 3.93 ips with data increment size of .039 x .039 in. in scan and index direction. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Corrosion Monitoring System suits water treatment facilities.

June 18, 2010

CorrTran® AQUA monitors water and wastewater processes for general and localized corrosion, enabling users to determine effectiveness of corrosion inhibitors. It also enables users to detect and correct corrosion issues for preventative maintenance. When measurement cycle is complete, corrosion rate and pitting value are calculated and relayed to plant personnel as 4-20 mA HART signal. System includes main unit, 100 psi working pressure probe, 10 ft cable, and steel or copper electrodes. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Test Cabinet offers temperature range of -30 to +90°C.

January 20, 2004

Model CCX Advanced Cyclic Corrosion Cabinet with 90°C option features temperature-resistant materials for dispersion towers and connectors, temperature-resistant fiberglass shell and gel coat, fiberglass cover with tempered-glass viewing window, and insulation around exposure zone. Unit replicates stresses that result in degradation including salt-saturated air and salt spray, high humidity, condensation, sunlight, and temperature variations. Read More

Test & Measuring Instruments

Corrosion Detection Transmitters offer real-time monitoring.

December 31, 2003

Corrosion Detection Transmitters allow user to monitor, online, effectiveness of corrosion inhibitors, and to detect and correct corrosion issues through preventive maintenance. They feature 2-wire, loop-powered, 4-20 mA signal with HART protocol. Suited for direct or remote mounting, transmitters can be located in general-purpose and hazardous locations. Probes are available in various styles and materials so they satisfy most applications. Read More

  • 1