Test & Measuring Instruments ->
Indicators
Indicators
(Showing headlines 461 - 480) << 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
|
 Weight Indicator handles wide variety of applications.Avery Weigh-Tronix
Fairmont, MN 56031
Oct 16, 2006
Usable in stand-alone as well as process control weighing applications, Evolution(TM) E1110 Multi-Application Configurable Indicator can be integrated with existing industrial networks and SCADA systems. It stores up to 10 recipes, each with up to 50 programmable steps, and performs process control without PLC. Along with totalizing feature, indicator has Truck Fleet Management feature; 8-digit, 1 in. yellow LED display; and alarm mode with 20 independent cutoffs.
|
 Dual pH Meters feature non-glass or glass design.Paul N. Gardner Co., Inc.
Pompano Beach, FL 33060 6608
Oct 09, 2006
Waterproof, NEMA4x-rated Model IQ160 measures pH, mV, temperature, and ORP. It features automatic or manual temperature compensation, automatic buffer recognition of 7 buffers, and up to 3-point calibration. Stainless steel pH probe has virtually unbreakable sensor that stores dry and needs no maintenance. Providing multi-parameter capabilities, Model IQ170 has all features of IQ160, plus ability to measure conductivity, TDS, and salinity.
|
 AC RMS Panel Meter is UL-listed.Laurel Electronics, Inc.
Costa Mesa, CA 92626
Oct 02, 2006
Laureate Model RMS 4½ digit meter provides 0.15% full scale accuracy for ac voltage or current signals from 10 Hz to 10 kHz. It offers 5 ac RMS voltage ranges from 200 mV to 300 V full scale and 4 ac RMS current ranges from 2 mA to 5 A full scale. High common mode rejection allows stable readings with current shunts located on high side of line, while 5 A input capability with 10 mW current shunt allows output of 5 A current transformers to be applied directly to meter.
|
 Pressure Gauges offer optional indicating transmitter.Mid-West Instrument
Sterling Heights, MI 48314
Sep 29, 2006
Utilizing convoluted elastomer diaphragm to separate high and low pressures, Models 140-142 are available with loop-powered, 8-28 Vdc, 2-wire, 4-20 mA transmitter. Differential pressure ranges from 0-20 in. H2O to 0-100 psid with accuracy of ±2% from 20-100% FS. Gauge fronts are corrosion-resistant plastic, and pressure containing elements are available in aluminum, brass, or 316 SS. Safe working pressure is 3,000 psig for aluminum and 316 SS and 1,500 psig for brass.
|
 Load Measurement System offers wireless functionality.Tekscan, Inc.
South Boston, MA 02127
Sep 25, 2006
Promoting flexibility of use for force and pressure sensors in product research, quality assurance, and testing applications, Wireless ELF(TM) enables laptop or PC to capture and store force data from event up to 200 ft away. It combines 0.008 in. thin piezoresistive FlexiForce® single-element load sensors with USB-powered hub, battery-operated transmitter, and software that displays real-time data in pounds, grams, or Newtons. Users can view data digitally or in chart format.
|
 Monitors measure pollution in industrial water emissions.Analytical Technology, Inc.
Oaks, PA 19426
Sep 21, 2006
AutoClean suspended solids/turbidity and pH monitors help European food manufacturers comply with IPPC (Integrated Pollution Prevention Control) regulations for controlling water emissions. D15/76 suspended solids/turbidity monitor measures optical clarity of water from 0-10 mg/l to 0-10,000 mg/l. Using Q25 pH sensors, Q45P AutoClean pH monitor can be used to check pH levels of any water emission.
|
 Digital Indicators are available with USB interface.Mahr Federal Inc.
Providence, RI 02905
Sep 19, 2006
MarCator Digital Indicators feature USB connectivity that allows multiple indicators to be linked to PCs through USB hub, without multiplexer. With large LCD displays, MarCator 1086 and 1087 include integral tolerance function that can display measured values within tolerance zone, or indicate in- or out-of-tolerance conditions without measured values. Indicators also come with button lock function, in./mm selection, ABS feature, and adjustable factor.
|
 In-Line Sensor monitors pH of liquid chemicals.Norcross Corp.
Newton, MA 02458 1829
Sep 13, 2006
Installed directly in fluid line, In-Line pH Sensor incorporates transmitter, which converts mV signal to 4-20 mA for transmission to controller. Featuring flat tip probe with glass insert, sensor has integral reservoir, which traps fluid to keep probe tip wet during job changes and to prevent drying out. Applications include liquid chemical processes such as water-based printing inks, food production, pharmaceutical, and general manufacturing.
|
Data Acquisition Module offers current monitoring.Spectrum Control, Inc.
Fairview, PA 16415
Sep 13, 2006
Employing monitoring computer and 6 dual current sensing modules, Data Acquision Module 7832M-02 measures voltage and amount of current draw present at strategic points in system and verifies that system is operating within specified metrics. Data is transmitted via SNMP, but use of Telnet and serial communications is also supported. In addition to monitoring and reporting system aspects, module also helps identify circuit breaker trips and early stage device failures.
|
 Indicators suited agribusiness weighing applications.Avery Weigh-Tronix
Fairmont, MN 56031
Sep 11, 2006
Comprised of 3 programmable models, 640 Series indicates gross and net weights and has pushbutton tare function for temporary zeroing. Backlit LCD displays (1.1 in. for 640 and 640M and 2 in. for 640XL) feature 10 adjustable brightness levels. Capable of manual or automatic accumulation, products store data in 100+ memory channels as alpha or numeric symbols. Additional features include motion filtering device, Auto-LOC function, and optional RS-232 bi-directional serial port.
|
 Handheld pH Meters feature -2.00 to 19.99 pH range.Cole-Parmer Instrument Co.
Vernon Hills, IL 60061
Sep 08, 2006
IP67-rated Oakton® 600 Series waterproof meters feature accuracies to ±0.002 pH and are expandable to 0.001 resolution. Units store up to 500 data sets through automatic, manual, or timed collection. Calibration abilities include up to 6 calibration points, user-settable calibration-due alarm, and up to 15 buffer options with auto buffer recognition of USA, NIST, DIN, and PWB standards. Infrared IrDA wireless technology enables printing and PC downloading.
|
 Power Monitor manages energy in manufacturing environments.Rockwell Automation
Milwaukee, WI 53204
Aug 30, 2006
Available in 5 models, Powermonitor 1000 profiles plant's energy consumption and utilization data and can be applied independently for collecting and charting energy information or integrated into existing energy monitoring systems. Transducer models TR1 and TR2 provide power factor monitoring and measure voltage, current, and power-related tags. Energy-monitor models EM1, EM2, and EM3 measure consumption related tags such as real, reactive, and apparent energy.
|
 Three-Phase Monitoring Relays protect machinery and people.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Aug 25, 2006
Provided in 177-275 Vac and 323-550 Vac ranges, DIN rail mount Series DPB71 monitors for overvoltage, undervoltage, phase sequence, and phase loss situations on 3 phase and 3 phase+ neutral systems. Capable of monitoring 50-60 Hz, Series DPC01 is available in ranges from 115 Vac delta voltage through 690 Vac delta or star voltage. Units provide True RMS monitoring for over and under voltage, phase sequence, phase loss, and symmetry on 3 phase and 3 phase+ neutral systems.
|
Indicator Alarms target plastics industry.Eurotherm Controls Ltd
Worthing East Suss BN13 3PL United Kingdom
Aug 11, 2006
Series 3200i indicators include melt pressure alarm unit, which is DIN3440-approved. Horizontal unit 32h8i is 1/8 DIN and features scrolling text messaging, 2 relay outputs, digital IO, and Modbus communications. Process inputs include strain gauge for melt pressure or universal for thermocouple, RTD, and 4-20 mA. At 1/16 DIN, 3216i has universal input, up to 3 relay outputs, and non-isolated dc retransmission capability. At ¼ DIN, 3204i has similar features.
|
 Piezoelectric Alarms suit cold temperature environments.Floyd Bell, Inc.
Columbus, OH 43085
Aug 10, 2006
Blizzard(TM) Series Alarms are microprocessor-based, audible alerts that auto-adjust to optimum volume for temperature when activated. This results in delivery of louder alarm for extreme cold weather applications. Alarms are available in various configurations, based on desired tone-type or termination.
|
 Inclinometers suit construction and off-road equipment.Rieker Inc.
Aston, PA 19014
Aug 04, 2006
Housed in environmentally protected, Zinc metal package, H4 Series provides single-axis inclination sensing with angle ranges of ±30, ±45, and ±70°. Units are available with 0-5 V analog outputs, or digital serial outputs, which transmit angle, in decimal format, in continuous stream of readings. They incorporate liquid capacitive sensing element for vibration damping with 2 levels of integrated temperature compensation, depending on required accuracy.
|
 Power Monitor offers alternative to analog power meter.Rockwell Automation
Milwaukee, WI 53204
Aug 02, 2006
Powermonitor 1000 profiles plant energy consumption and utilization data while providing information needed to control and optimize energy costs. In addition to basic power monitoring applications, product scales to provide advanced capabilities such as wiring diagnostics, historical trending, and advanced networking. Transducer models provide power factor monitoring and can measure voltage, current, and power-related tags. Energy-monitor models measure consumption related tags.
|
 Single Gas Monitor is offered with Hydrogen Cyanide sensor option.Industrial Scientific Corp.
Oakdale, PA 15071 1500
Aug 01, 2006
Operated via 4-button interface, dockable GasBadge® Pro with HCN sensor option is suited for use in precious mining, gold plating, food and beverage, and hazardous materials industries. It can be adapted with interchangeable smart sensors to monitor unsafe levels of oxygen or any one of 9 other toxic gases. Audible, vibrating, and visual alarms indicate when set ranges are exceeded, and backlit LCD displays gas and concentration level. Product logs up to one year of survey data.
|
Voltage Monitor features 4 different measurement inputs.Linear Technology Corp.
Milpitas, CA 95035
Aug 01, 2006
LTC2914 voltage monitor IC contains undervoltage (UV) and overvoltage (OV) inputs and allows specific UV and OV trip threshold configuration with ±1.5% accuracy of monitored voltages. Buffered reference output and 3-state input polarity-select pin allow monitoring of 2 separate negative voltages. Featuring input glitch filters that eliminate noise and 70 µA quiescent current, IC is suited for telecom/network equipment, storage servers, and desktop and notebook computers.
|
 Portable Power Meter offers USB connectivity.Berkeley Varitronics Systems
Metuchen, NJ 08840-1217
Jul 05, 2006
With measuring range of 800 MHz to 2.2 GHz and ±0.5 dB accuracy, YellowFrog(TM) connects directly to Gator(TM), Dragon(TM), Lizard, or any CW transmitter with type N out for instant verification of power levels in dBm or Watts. Handheld unit weighs under 2 lb and has USB port for power and PC communication. Provided with LCD display, product operates continuously on 2 AAA Ni-MH batteries for 8+ hr and comes with PC controller/monitoring software.
|
(Showing headlines 461 - 480) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
|
|
|