ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
Fluid & Gas Flow Journal
Machining Journal
Procurement Journal
Tech Trends Journal
 Industry News
Latest New Product News
Association & Government News
Thought Leaders
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Newsletter Archive
SME
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
Call for Contributors, Guest Writers and Submissions
How to Write an effective Press Release
Trade Associations
Test & Measuring Instruments -> Counters -> Totaling Counters


Totaling Counters







(Showing headlines 1 - 20)   more ....

Large Display Electronic Counter features 6 LED digits.

Bontrol Systems    Martinez, CA 94553
Sep 15, 2014 Able to be directly connected to input signal source with up to 1 kHz count speed, G90 Series features 6 LED digits up to 4 in. high x 2.36 in. wide. Counting mode is add/subtract and quadrature with reset accomplished remotely. Operating from 100–240 Vac, counter has built-in memory for count value retention in case of power loss. External 12 Vdc power supply is available for sensors, and other features include decimal point position, free write, and input inhibition.

Electronic Counter transmits totals via Ethernet, 4-20 mA outputs.

Electronic Counter transmits totals via Ethernet, 4-20 mA outputs.

Laurel Electronics, Inc.    Costa Mesa, CA 92626
Jul 28, 2014 Available in Basic and Extended versions, ETL-rated L60007FR can output totals digitally via Ethernet I/O as well as scaled, isolated 4–20 mA analog signal. Dual channels A and B can be independently scaled to count up from zero (or other value) to preset limit or down from preset value to zero (or other limit). Input flexibility is provided by universal dual-channel signal conditioner, and counter also has built-in isolated 5, 10, or 24 Vdc excitation supply.

Flow Rate/Totalizers feature dual analog or pulse inputs.

Precision Digital Corp.    Natick, MA 01760 2414
Aug 06, 2013 Featuring independent programming of inputs, including separate selection of input type and scaling, ProVu® PD6262 supports dual analog inputs of 0–20 mA, 4–20 mA, 0–5 V, 1–5 V, or ±10 V, while ProVu® PD6363 supports dual pulse inputs, including square wave, open collector, NPN, PNP, TTL, or switch contact signals. Both 1/8 DIN meters provide integrated math functions for rate or total flow calculations. For hazardous areas, meters are available as explosion-proof, IP68/NEMA 4X ProtEX®-MAX models.

Flow Rate Meter/Totalizer has explosion-proof design.

Precision Digital Corp.    Natick, MA 01760 2414
Feb 19, 2013 Designed for display of local or remote flow information in hazardous areas or harsh safe area applications, PD6830 ProtEx®-RTP Pulse Input Rate/Totalizer comes in NEMA 4X, cast aluminum enclosure and carries FM, ATEX, CSA, IECEx, and CE approvals. SafeTouch® through-glass buttons allow operation without removing cover, and flowmeter k-factor units are automatically converted to desired display units. Pulse input accepts range of flow transmitter signals as well as high frequency signals.

Multifunction Devices operate as timers, counters, tachometers.

Multifunction Devices operate as timers, counters, tachometers.

AutomationDirect.com    Cumming, GA 30040-9905
Apr 19, 2012 Available in standard 1/16 DIN size, CTT series accepts voltage and non-voltage inputs from NPN, PNP, or dry contact sensors and can operate as digital counter, timer, combination timer/counter, or tachometer. Counting speeds are selectable to 10,000 cycles/sec, and double-line, 6-digit, 2-color LCDs present values and facilitate setup. While Output 1 is SPST relay and NPN transistor that operate concurrently, Output 2 is available as SPDT relay or NPN transistor.

Flow Totalizer can be used as monitor or controller.

Aalborg Instruments    Orangeburg, NY 10962
Feb 28, 2012 Aalborg®'s TIO totalizer can be used as monitor for GFM and AFM flow meters or as controller with GFCs and AFCs. It converts analog mass flow meters and controllers into precision digital units via RS 232 or RS 485 interfaces (multi-drop capacity up to 64 devices). Two fully independent programmable totalizers allow up to 9 digit total readings and are updated every 100 msec. Totalizer can be used with third party devices with 0-5 Vdc / 4-20 mA inputs and outputs.

Multifunction Counter Module has USB-powered design.

Multifunction Counter Module has USB-powered design.

J-Works, Inc    Sylmar, CA 91342
Apr 02, 2010 Available with on board terminal block (screw type) connections or Molex KK series 2 pc pluggable connectors, USB 2.0-controlled JSB542 series DAQ module provides 4 channels of 24-bit counters. Each can be configured as 1 of 5 types of counters: Frequency, Period, Time between pulses, Quadrature, and Event. While Period and time counters have selectable time base of 1-100 MHz, frequency counter has selectable gate times from 1 msec to 2 sec.

Event Data Logger can store 50,000 events on internal memory.

Event Data Logger can store 50,000 events on internal memory.

AEMC Instruments    Foxborough, MA 02035
Dec 21, 2009 Working with dry contact closure or 0-3 and 0-5 Vdc logic levels, Simple Logger® II Model L404 is suited for determining machinery run/down times and event sequencing, counting events, and recording event duration. It offers user programmable event measurement scaling and comes with DataView® software, which provides real-time viewing of measurement data. Battery operation and compact size facilitate installation in tight spaces, while front panel LEDs indicate logger's status.

Mold Counter monitors mold operation and validates data.

Mold Counter monitors mold operation and validates data.

D-M-E Company    Madison Heights, MI 48071-2383
Jun 12, 2009 Using non-resettable, mechanical, 7-digit counter, CounterView records accurate number of mold cycles, and relies on sensor that detects when mold has closed. Each mold cycle triggers display to increase or decrease counting mechanism based on user preference. CounterView also validates process monitoring data and assists mold maintenance procedures. Operating to 250°F, product is available in inch and metric standards and features glass-filled nylon housing.

Totalizer calculates and displays flow rates/totals.

Totalizer calculates and displays flow rates/totals.

Trimec Europe Ltd    West Sussex   United Kingdom
Mar 02, 2009 Model RT20 calculates and displays flow rates and totals from flowmeters with pulse, sine wave, or frequency outputs. Available as battery operated or externally powered device, it features 6 digit LCD total, 8 digit cumulative, and 5 digit rate display. Housed in IP66/67 rated aluminum field- and panel-mountable housing, product also includes scaleable universal pulse or frequency inputs, scaled pulse output, non-volatile memory and reverse polarity protection.

Time-to-Digital Converter offers 5 picosec timing resolution.

Agilent Technologies, Inc.    Santa Clara, CA 95051
Dec 03, 2008 Model U1050A-002 of U1050A line of Acqiris time-to-digital converters has measurement range of up to 20 sec and ratio of 1:4.109. Module can operate in either single-start or multi-start acquisition modes with timing information on all 13 independent channels encoded relative to common channel. Time measurement on unit can be based on either internal low jitter of less than 3 ps rms, high stability of ±2 ppm clock source, or external 10 MHz reference input.

Rate Indicator/Totalizer uses HART communications protocol.

Rate Indicator/Totalizer uses HART communications protocol.

Hoffer Flow Controls, Inc.    Elizabeth City, NC 27909
Aug 27, 2008 Compatible with Hoffer turbine flowmeters and other frequency producing flowmeters, HRT1 rate and total indicator features 20-point linearization, scaled pulse output, and 4-20 mA loop powered analog output. HART® protocol allows communication with processor via software or handheld communicator, enabling settings adjustment and diagnostic checks. Other features include rate, total, and grand total display as well as 2 optional alarm outputs configurable for rate and total.

Electronic Hand Tally has 5-digit display.

Electronic Hand Tally has 5-digit display.

ENM Company    Chicago, IL 60646 6135
Mar 27, 2008 Powered by replaceable internal battery and measuring 3.65 x 2.20 x 0.80 in., Series L17 Electronic Hand Tally counts both up and down and can be reset with push of button. Audible sound option to signal counting can be turned on and off, and battery will last approximately 2 yr with sound turned off.

Time-to-Digital Converter features 6 stopwatches.

Agilent Technologies, Inc.    Santa Clara, CA 95051
Aug 01, 2007 Suited for time measurement applications, Model TC890 records multiple events or hits on each of 6 input channels, with timing resolution of 50 ps and mean dead time between sequential pulses on same input of less than 15 ns. Precision time measurement is achieved with less than 3 ps rms jitter and ±2 ppm stability. Running at full speed, instrument offers 25 million events/sec data-throughput. It enables event counting or histogram creation for data and spectra comparison.

Panel Meter displays rates or totals up to 6-digits.

Panel Meter displays rates or totals up to 6-digits.

Laurel Electronics, Inc.    Costa Mesa, CA 92626
Feb 08, 2007 Laureate Model VF programmable panel meter and process signal totalizer is UL-listed, and displays rates or totals from transducers with 4-20 mA, 0-1 mA, or 0-10 V process signal output. Suited for flow and non-flow applications, unit converts analog signal to frequency, which is converted to rate with accuracy of ±0.02% of full scale at 25 readings/sec. Adaptive filter reduces variations due to noise while responding to actual changes in signal level.

Counters use input/output boxes for added capabilities.

Heidenhain Corp.    Schaumburg, IL 60173-5337
Jan 30, 2007 Compatible with manual machine tools up to 3 axes, ND 780 DRO uses Model IOB 49 to provide 2 additional functions, depending upon application. When milling application is active, switching functions can be executed, and when turning application is active, IOB 49 makes it possible to machine with constant cutting speed. For machines with up to 6 axes, POSITIP 880 uses IOB 89 for 8 additional switching inputs and 9 switching outputs. Both IOBs are rail-mounted in electrical cabinet of machine.

Flow Indicators suit analog signal applications.

Flow Indicators suit analog signal applications.

Dwyer Instruments, Inc.    Michigan City, IN 46361
Nov 21, 2006 Accepting all standard process signals such as 4-20 mA, 1-5 V, and 0-5 V, Series FIV flow rate/totalizer/batch controllers feature 7-segement LED display that provides 4½ digits of flow rate and 6 digits of total. For applications requiring more than display of rate or total, meters can be equipped with 2 relays and 4-20 mA retransmission output. Relays can also be used for alarming based on flow rate or for batch controlling based on flow total.

Dual Channel Counter suits industrial process monitoring.

Laurel Electronics, Inc.    Costa Mesa, CA 92626
Nov 13, 2006 Designed for pulse rates from 0.05 Hz-1 MHz, UL-rated Laureate Model FRR counter can add, subtract, divide, and multiply 2 independently scalable pulse or AC input channels. Universal dual-channel signal conditioner accepts magnetic signals from 12 mV-250 Vac as well as signals from proximity switches with PNP or NPN output, TTL or CMOS logic, and contact closures. Built-in isolated 5, 10, or 24 Vdc excitation supply for powering proximity switches and other sensors is included.

Digital Counter is suited for lab and plant use.

Digital Counter is suited for lab and plant use.

Control Company    Friendswood, TX 77546
Feb 13, 2006 With display that reads to 99,999, water-resistant Digital Counter features O-ring-sealed and shock-resistant ABS plastic case. Counter is electronic, with solid-state construction that eliminates gear and miscount problems. Tactile click buttons provide positive action, and fail-safe design eliminates accidental reset. Measuring 2 5/8 x 1 2/3 x 5/6 in., battery-powered unit weighs 1 oz and provides over 2 years of continuous operation.

Laser Copy Counters are suited for fine sheet counting.

Laser Copy Counters are suited for fine sheet counting.

Baumer Ltd.    Southington, CT 06489 1534
Oct 18, 2005 Programmable SCATEC-10 and SCATEC-15 sensors, designed for non-contact counting, can also be used in applications involving lap or shingle stream counting. Both include keypad, LCD display, additional connector, and retro-reflective device that counts separated sheets. Able to be connected to computer for remote control and programming, products come with ScaDiag software and can detect sheets down to 0.1 or 0.15 mm at rates to 1.5 million copies/hr.




(Showing headlines 1 - 20)   more ....


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy