Combination Time/Pulse Meter has DIN rail mount design.

September 24, 2014

Used for field testing and recording of elapsed time and on/off cycles as well as maintenance schedule periods, D9454M1 consists of hour meter and event counter. These two meters are connected in parallel (common connections) in standard version to simultaneously keep track of number of occurrences and time, but meters can also act independently of each other. With IP52 rated front side and resistant to shock, product features 0.16 x 0.067 in. digits and operates from 5 to 122°F. Read More

Test & Measuring Instruments

Large Display Electronic Counter features 6 LED digits.

September 15, 2014

Able to be directly connected to input signal source with up to 1 kHz count speed, G90 Series features 6 LED digits up to 4 in. high x 2.36 in. wide. Counting mode is add/subtract and quadrature with reset accomplished remotely. Operating from 100–240 Vac, counter has built-in memory for count value retention in case of power loss. External 12 Vdc power supply is available for sensors, and other features include decimal point position, free write, and input inhibition. Read More

Test & Measuring Instruments

Electronic Counter transmits totals via Ethernet, 4-20 mA outputs.

July 28, 2014

Available in Basic and Extended versions, ETL-rated L60007FR can output totals digitally via Ethernet I/O as well as scaled, isolated 4–20 mA analog signal. Dual channels A and B can be independently scaled to count up from zero (or other value) to preset limit or down from preset value to zero (or other limit). Input flexibility is provided by universal dual-channel signal conditioner, and counter also has built-in isolated 5, 10, or 24 Vdc excitation supply. Read More

Test & Measuring Instruments

Flow Rate/Totalizers feature dual analog or pulse inputs.

August 6, 2013

Featuring independent programming of inputs, including separate selection of input type and scaling, ProVu® PD6262 supports dual analog inputs of 0–20 mA, 4–20 mA, 0–5 V, 1–5 V, or ±10 V, while ProVu® PD6363 supports dual pulse inputs, including square wave, open collector, NPN, PNP, TTL, or switch contact signals. Both 1/8 DIN meters provide integrated math functions for rate or total flow calculations. For hazardous areas, meters are available as explosion-proof, IP68/NEMA 4X ProtEX®-MAX models. Read More

Test & Measuring Instruments

Flow Rate Meter/Totalizer has explosion-proof design.

February 19, 2013

Designed for display of local or remote flow information in hazardous areas or harsh safe area applications, PD6830 ProtEx®-RTP Pulse Input Rate/Totalizer comes in NEMA 4X, cast aluminum enclosure and carries FM, ATEX, CSA, IECEx, and CE approvals. SafeTouch® through-glass buttons allow operation without removing cover, and flowmeter k-factor units are automatically converted to desired display units. Pulse input accepts range of flow transmitter signals as well as high frequency signals. Read More

Test & Measuring Instruments, Timers & Clocks

Multifunction Devices operate as timers, counters, tachometers.

April 19, 2012

Available in standard 1/16 DIN size, CTT series accepts voltage and non-voltage inputs from NPN, PNP, or dry contact sensors and can operate as digital counter, timer, combination timer/counter, or tachometer. Counting speeds are selectable to 10,000 cycles/sec, and double-line, 6-digit, 2-color LCDs present values and facilitate setup. While Output 1 is SPST relay and NPN transistor that operate concurrently, Output 2 is available as SPDT relay or NPN transistor. Read More

Test & Measuring Instruments, Controls & Controllers, Sensors, Monitors & Transducers

Flow Totalizer can be used as monitor or controller.

February 28, 2012

Aalborg®'s TIO totalizer can be used as monitor for GFM and AFM flow meters or as controller with GFCs and AFCs. It converts analog mass flow meters and controllers into precision digital units via RS 232 or RS 485 interfaces (multi-drop capacity up to 64 devices). Two fully independent programmable totalizers allow up to 9 digit total readings and are updated every 100 msec. Totalizer can be used with third party devices with 0-5 Vdc / 4-20 mA inputs and outputs. Read More

Test & Measuring Instruments

Event Data Logger can store 50,000 events on internal memory.

December 21, 2009

Working with dry contact closure or 0-3 and 0-5 Vdc logic levels, Simple Logger® II Model L404 is suited for determining machinery run/down times and event sequencing, counting events, and recording event duration. It offers user programmable event measurement scaling and comes with DataView® software, which provides real-time viewing of measurement data. Battery operation and compact size facilitate installation in tight spaces, while front panel LEDs indicate logger's status. Read More

Test & Measuring Instruments

Totalizer calculates and displays flow rates/totals.

March 2, 2009

Model RT20 calculates and displays flow rates and totals from flowmeters with pulse, sine wave, or frequency outputs. Available as battery operated or externally powered device, it features 6 digit LCD total, 8 digit cumulative, and 5 digit rate display. Housed in IP66/67 rated aluminum field- and panel-mountable housing, product also includes scaleable universal pulse or frequency inputs, scaled pulse output, non-volatile memory and reverse polarity protection. Read More

Test & Measuring Instruments, Computer Hardware & Peripherals

Time-to-Digital Converter offers 5 picosec timing resolution.

December 3, 2008

Model U1050A-002 of U1050A line of Acqiris time-to-digital converters has measurement range of up to 20 sec and ratio of 1:4.109. Module can operate in either single-start or multi-start acquisition modes with timing information on all 13 independent channels encoded relative to common channel. Time measurement on unit can be based on either internal low jitter of less than 3 ps rms, high stability of ±2 ppm clock source, or external 10 MHz reference input. Read More

Test & Measuring Instruments

Electronic Hand Tally has 5-digit display.

March 27, 2008

Powered by replaceable internal battery and measuring 3.65 x 2.20 x 0.80 in., Series L17 Electronic Hand Tally counts both up and down and can be reset with push of button. Audible sound option to signal counting can be turned on and off, and battery will last approximately 2 yr with sound turned off. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Dual Channel Counter suits industrial process monitoring.

November 13, 2006

Designed for pulse rates from 0.05 Hz-1 MHz, UL-rated Laureate Model FRR counter can add, subtract, divide, and multiply 2 independently scalable pulse or AC input channels. Universal dual-channel signal conditioner accepts magnetic signals from 12 mV-250 Vac as well as signals from proximity switches with PNP or NPN output, TTL or CMOS logic, and contact closures. Built-in isolated 5, 10, or 24 Vdc excitation supply for powering proximity switches and other sensors is included. Read More

Test & Measuring Instruments

Tally Counter is offered in add/subtract version.

March 4, 2005

Electronic 4-digit Hand Tally provides audible beep, which can be turned on or off, to signal each count and help prevent miscounts. Manufactured from impact-resistant plastic, counter features all-electronic components, with no moving parts to wear. Unit is suited for applications where items need to be counted and recorded, such as occupancy, inventory control, attendance monitoring, traffic recording, and lab work. Read More

Test & Measuring Instruments

Hour Meters and Event Counters are Palm(TM) compatible.

October 22, 2004

Designed to MIL-M-7793/14, solid-state, panel-mount DDS200 Series lets users monitor and store warranty or maintenance data. Model DDS200 records time that power has been applied up to 99,999.99 hr, while Model DDS201 Event Counter records number of times power has been applied for at least 5 sec up to 9,999,999 counts. Both can be interrogated using DDR-1 Palm(TM)-based reader, which allows user to take reading, log and store information, and synchronize files with desktop computer. Read More

Test & Measuring Instruments

Electric Counter features 8-digit display.

September 1, 2004

Tamper-proof Series E8B provides 1,500 counts per minute and life count of 10 million. Voltage may be applied to count coil continuously without causing damage. Connecting with 22 AWG leads from bottom of counter, unit may be panel, base, rear, or PC mounted. Operating temperature is -25 to 65°C. Counter is UL, CSA, and CE recognized, and is interchangeable with 6-digit counter E6B. Read More

Test & Measuring Instruments

Electronic Counter is suited for inventory control.

July 20, 2004

Manufactured from impact-resistant plastic, Model E2 electronic 4-digit Hand Tally counter has no moving parts and produces audible beep that signals each count in order to prevent miscounts. Product is suited for any application where items need to be counted and recorded. Specific uses include inventory control, attendance monitoring, traffic recording, and lab work. Read More

Test & Measuring Instruments, Timers & Clocks

Hand-Held Event Timer synchronizes with GPS timing.

July 9, 2004

GPS Synchroniser units connect to equipment that provides logic output in order to give time stamp to events using GPS timing as reference. Units can be used individually to derive absolute independent event time or in groups to compare timing of different remote events. Products feature backlit display and store results in 512 last in/first out non-volatile buffer that can then be read out using RS-232 serial cable. Time resolution is 1 microsecond, and accuracy is ±2 microseconds. Read More

Test & Measuring Instruments

Battery-Powered Flow Totalizer offers multi-year operation.

June 21, 2004

Signet 8150 uses standard lithium batteries, suitable for remote or mobile installations where access to line power is limited. Unit is offered with 3 totalizers; 2 are resettable for long and short term monitoring and third is permanent. Four-button keypad and intuitive software allow menu-driven operation, while security access code prevents unwanted changes. LCD displays flow rate and total flow volume simultaneously. Integral and panel-mounted styles are available. Read More

Test & Measuring Instruments

Ratemeter/Totalizer includes setup and monitoring software.

February 17, 2004

Model BATRT-M features 5 digits of rate and 8 digits of total. Instrument can be powered from internal battery, external DC supply, or 4-20 mA output loop, and accepts magnetic pickup, DC pulse, and switch-closure inputs. Software lets users create, save, open, download, upload, and print setup information for instrument, as well as view rate and total on PC. BATRT-M is rated for -22 to +158°F operation with accuracy of 0.01% of reading ±1 count. Read More

Test & Measuring Instruments, Controls & Controllers

Digital Panel Meter suits process control industry.

February 5, 2003

Model 3830 SMART Rate/Totalizer panel meter includes up to one Form-A, 5 A and three Form-C, 5 A output relays. Microprocesser-based process controller offers 4 analog outputs or RS 232 serial communication. Active in background or foreground, 6-digit totalizer delivers scaled pulsed output to PLCs or other controllers. Unit is available in various DC voltage or current inputs: 0-5 Vdc, 0-10 Vdc, and 4-20 mA. Aluminum case and NEMA 4 front bezel are standard. Read More