 Water Tester detects total coliforms and E. coli.Industrial Test Systems, Inc.
Rock Hill, SC 29730
Oct 02, 2008
Compliant with USEPA, EZ Coliform Cult - MUG Test consists of sterilized, ready-to-use 120 mL bottle containing premeasured amount of growth media. To run test, user adds water sample, caps bottle, and then incubates at 35°C for 24 hr. If coliforms are present, liquid sample will change from yellow to blue-green in color. If E. coli is present, sample will glow bright blue fluorescent color when illuminated with UV light.
|
Water Isotope Analyzer offers automated, turnkey operation.Picarro Inc.
Sunnyvale, CA 94085
Aug 26, 2008
Fully automated for running large sample batches, Picarro L1102-i simultaneously measures delta-18 O and delta-D directly from water samples with respective sensitivities of less than 0.1 and 0.5 parts per thousand. Instrument requires little or no sample preparation, provides data in minutes, and utilizes wavelength-scanned cavity ring down spectroscopy engine. Robotic autosampler and vaporization accessory enables many samples to be analyzed in one automated, hands-free sequence.
|
 Residual Chlorine Monitor is portable and battery powered.Analytical Technology, Inc.
Oaks, PA 19426
Aug 22, 2008
Utilizing membrane-covered polarographic sensor that does not require addition of chemical reagents, Model Q45H/62 Residual Chlorine Monitor allows on-line control of chlorination systems without use of reagents or mains power and enables direct installation into water and wastewater networks. Available with 2 data logging options, it comes in shock-proof, water-resistant casing. Unit has optional pH compensation feature to eliminate free chlorine error caused by process pH drift.
|
Battery/Electrical Analyzers suit automotive applications.Midtronics, Inc.
Willowbrook, IL 60521
Aug 14, 2008
Battery conductance and electrical system analyzers of MDX-600 Series utilize industry standard conductance technology and offer user interface that promotes accurate analysis. All feature backlit screen and removable cable design and are offered with integrated printer option. Models 650/650P offer quick starter analysis, without disabling ignition, and menu-driven interface for complete charging system analysis.
|
 Chlorine Analyzer has pre-wired, panel mount design.Electro-Chemical Devices, Inc.
Yorba Linda, CA 92887
Aug 01, 2008
FCA-22 Analyzer System monitors free chlorine in drinking water, rinse water, cooling water, and other fresh water samples from 0.05-20.0 ppm Cl2, 5-9 pH, and at temperatures from 32- 122°F. Constant head flow control device maintains optimum water flow past sensor over 10-80 gph incoming flows. Incorporated pH sensor provides compensation for samples from 6.5-9 pH, and Cl2 sensor's polarographic, gold/silver PFTE membrane construction extends sensor life.
|
 At-Line Automation Analyzer targets food process industry.Brinkmann Instruments, Inc.
Westbury, NY 11590
Jun 23, 2008
Utilizing micro sample loops, overflow pipettes, pumps, valves, stirrers, and Dosinos®, Metrohm® ProcessLab analyses pH, acid value, chloride and vitamin C, all without operator intervention. It can be equipped with high-speed homogenizer for dissolution of solids as well as hot water to dissolve powders. Hermetical separation of electronics resists dust/liquids, while industrial PC and PLC driven controller allows for extensive communication within process environment.
|
Multiparameter Analyzers offer digital communications.Emerson Process Management / Process Liquid Division / Uniloc Division
Irvine, CA 92606
May 16, 2008
Rosemount Analytical® Model 1056-HT and 1056-DP are 4-wire, dual-input analyzers that feature, respectively, complete HART® and Profibus® DP digital communications. HART-enabled analyzer allows remote calibration, continuous monitoring of 4 live process variables, and configuration from AMS® Suite or DeltaV(TM) host applications, legacy DCS, or SCADA systems. Diagnostics allows plants to estimate life of in-process sensors and perform required maintenance on timely basis.
|
 FTIR Spectrometers enable on-site lubrication analysis.A2 Technologies, LLC
Danbury, CT 06810
Apr 29, 2008
Designed for lubrication analysis in various power industry systems, PAL instruments quantify water levels from 50-5,000 ppm in oils with accuracy of better than 5%. Products utilize Fourier Transform Infrared (FTIR) method, which requires no hazardous reagents. In addition to measuring water level, systems immediately yield amount of oxidation and nitration byproducts present as well as amount of anti-oxidation, anti-wear, and extreme pressure additives that remain in lubricant.
|
Work Cell targets chemistry testing market.Beckman Coulter, Inc.
Fullerton, CA 92834-3100
Mar 13, 2008
Consolidating chemistry and immunoassay testing targeted to high-volume laboratories, UniCel DxC 880i Synchron® Access® clinical system offers menu of more than 150 different chemistry and immunoassay tests, with 120 onboard. System can process up to 1,440 chemistry and 400 immunoassay tests/hr, respectively. It features closed-tube sampling and closed-tube aliquotting capabilities to eliminate de-capping and re-capping steps in laboratory process.
|
Water Vapor Analyzer provides continuous, in-situ operation.Picarro Inc.
Sunnyvale, CA 94085
Mar 11, 2008
Deployed in field or laboratory, Isotropic Water Vapor Analyzer measures oxygen and hydrogen isotopes in water vapor. Device measures single spectral features in flow cell with effective path length up to 12 km. High resolution and resulting specificity enable analyzer to discriminate between closely spaced spectral lines arising from different isotopic compositions in sample gas. Instrument is suited for source of origin monitoring, as well as water cycle and climate studies.
|
Water Tester enables precise and accurate analysis.Industrial Test Systems, Inc.
Rock Hill, SC 29730
Mar 07, 2008
Featuring built-in sample cell/cuvette, eXact® EZ Advanced Photometric System eliminates handling of cells to promote precision while also eliminating aggravation of lost/broken cells. Reagent delivery device, eXact® Strip, allows simultaneous introduction of reagents that must normally be kept segregated. Accurate to 0.01 mg/L, meter offers 25+ parameters for analysis and is designed to minimize test time. Meter cell capacity is 10 mL.
|
FTIR Systems enable in situ monitoring of chemical reactions.Mettler Toledo, Inc.
Columbus, OH 43240
Jan 10, 2008
Entry level ReactIR(TM) 15m is suited for organic chemist who needs chemical information, while high end ReactIR(TM) 45m is tool for chemical engineers and technologists who focus on process optimization and characterization. Designed for monitoring reactions that involve nitriles, ketenes, metal carbonyls, or isocyanates, SiComp AgX FiberConduit(TM) is silicon-based ATR sensor integrated with AgX fiber technology.
|
Drinking Water Analyzer detects pesticides and contaminants.Waters Corp.
Milford, MA 01757
Nov 12, 2007
AquaAnalysis System detects target analytes at or below 10 parts-per-trillion, meeting or exceeding regulatory standards worldwide. Liquid Chromatography-Based (LC) system offers analysis time of just 30 minutes. Requiring only 20 mL volumes of sample, unit employs parallel analysis system, and prepares second sample while first one is being analyzed.
|
Analyzer provides point-of-care diabetes management.Siemens Medical Solutions USA
Malvern, PA 19333
Oct 10, 2007
Designed to test glycosylated hemoglobin, Microalbumin/Creatinine, and Albumin-to-Creatinine, network-ready DCA Vantage(TM) Analyzer is critical for monitoring patient's glycemic control. Physicians can enter patient ID via touch screen or barcode, view on-board printed reports and HbA1c patient trending graphs, and download results to external HIT system. For testing sites that require control of decentralized testing, unit offers connectivity to LIS, QC reminders, test lock-out, and remote access.
|
Veterinary Hematology Analyzer displays results in 2 min.Abaxis, Inc.
Union City, CA 94587
Sep 24, 2007
VetScan HM5 provides 22-parameter complete blood count and 4 cellular histograms for cat, dog, and horse. It also offers 3-part mode for 7 other species. For operation, this fully automated, 5-part differential cell counter requires operator to enter appropriate patient information, insert well-mixed blood sample, and press Start button. Device requires minimal maintenance and also offers capabilities for database management.
|
 Intelligent Analyzer accommodates single-/dual-sensor input.Emerson Process Management, Rosemount Div.
Chanhassen, MN 55317
Aug 30, 2007
Offering unrestricted choice of dual measurements, Model 1056 multiparameter analyzer can address turbidity, flow, pH/ORP/ISE, resistivity/conductivity, percent concentration, chlorine, oxygen, ozone, and temperature. Quick-start screens, auto-recognition of each measurement board installed within device, and sensor configuration prompts aid setup, while LCD displays measurement diagnostics and facilitates multilingual, menu-based operation.
|
Bench-Top Reader facilitates in-house kinase profiling.Caliper Life Sciences, Inc.
Hopkinton, MA 01748
Aug 17, 2007
Featuring push-button operation, EZ Reader II provides choice of 4-sipper or 12-sipper LabChip microfluidic device to run assays. It enables real-time kinetic analysis, allowing researchers to study enzyme behavior over time in mechanism-of-action studies. ProfilerPro(TM) kinase reagent profiling kit, which allows broad range, rapid kinase profiling in-house, accompanies system.
|
DNA Bisulfite Modification Kit produces quick results.Sigma-Aldrich
St. Louis, MO 63103
Jul 20, 2007
Requiring as little as 50 pg of input DNA, Imprint(TM) DNA Modification Kit completely converts unmethylated cytosine to uracil in under 2 hr. Solution is based on Bisulfite DNA Modification technology, which enables scientists to determine methylation patterns throughout genome. Once deamination of cytosine to uracil is complete, resultant DNA product is suitable for downstream applications such as qPCR and bisulfite sequencing.
|
 Process Analyzer targets food industry.Brinkmann Instruments, Inc.
Westbury, NY 11590
Jul 11, 2007
Utilizing micro sample loops, overflow pipettes, pumps, valves, stirrers, and Dosinos®, Metrohm ProcessLab carries out pH, acid value, chloride, and vitamin C analyses, all without operator intervention. It can also be equipped with high-speed homogenizer for dissolution of solids as well as hot water to dissolve powders. Hermetical separation of electronics protects unit against dust and liquids. Industrial PC and PLC-driven controller allow for communication within process environment.
|
Turbidity Analyzer is suited for potable water plants.Emerson Electric Co.
St. Louis, MO 63136 8506
Jul 11, 2007
Available with universal ac-driven and 24 Vdc power supply options, Model 1056 is offered as single- or dual-input analyzer that measures turbidity, pH/ORP/ISE, conductivity, oxygen, chlorine, and ozone. Line-powered instrument features large high-contrast LCD display, intuitive menu screens, and 7 programmed languages. Four process variables or diagnostic parameters are displayed simultaneously from every screen, giving operators process information at a glance.
|