Advertisement
|
|
Test & Measuring Instruments ->
Analyzers ->
Chemical Analyzers ->
Fuel Analyzers
Fuel Analyzers
(Showing headlines 1 - 20) more ....
|
 Residual Gas Analyzers feature web-enabled design.MKS
Andover, MA 01810 2449
Oct 23, 2009
Featuring optimized electronics platform for data acquisition, Microvision 2 and e-Vision 2 offer stability for e-diagnostic, process monitoring, and general vacuum trouble-shooting applications. Ethernet connectivity enables users to access data from anywhere on TCP-IP network, providing solution to wide-scale multi-RGA installations. RGAs are available with variety of software control systems, including built-in web application, recipe-driven Process Eye Professional, and TOOLweb RGA.
|
Testing System combines sulfur, nitrogen, and halide detection.PAC Petroleum Analyzer Company L.P.
Pasadena, TX 77503
Oct 09, 2009
Compact, automated, and multi-configurable ANTEK MultiTek(TM) is one testing system capable of detection and analysis of unwanted chemicals, pollutants, contaminants, and corrosive elements. Specifically, it detects sulfur, nitrogen, and halides through process that includes combustion Ion Chromatography, Ultraviolet Fluorescence, and Chemiluminescence technologies. This platform works with solid, liquid, gas, and LPG samples.
|
 Chlorine Gas Sensor has extended calibration interval.Sierra Monitor Corp.
Milpitas, CA 95035 6825
Jul 23, 2009
Network-enabled smart gas sensor, 5100-06-IT, is standalone module with integral alarm relays and 6-month (180 day) calibration interval. Integration to existing plant-wide safety and monitoring systems is facilitated via 4-20 mA output, RS-485 Modbus interface, SentryBus interface, optional integral relay output, and digital display. Non-intrusive calibration, remote sensor option, and 316 SS enclosure options are also available.
|
 Benchtop Analyzer determines O2 and CO2 package headspace.MOCON
Minneapolis, MN 55428 1010
Jun 11, 2009
Targeting low-headspace pharma applications, PAC CHECKŪ Model 650 EC helps manufacturers know if correct balance of O2 and CO2 is being achieved to support shelf life and efficacy objectives. It determines exactly how much residual O2 and CO2 (0-100%) has been left inside rigid, semi-rigid, and flexible packages. Supporting automatic and manual gas sampling, analyzer incorporates Flo SmartŪ testing line blockage sensing system and Cal-SmartŪ one-button calibration.
|
Greenhouse Gas Analyzer takes simultaneous measurements.Picarro Inc.
Sunnyvale, CA 94085
Apr 03, 2009
Designed for continuous operation at altitudes up to 30,000 ft, G1301-m trace gas analyzer enables direct, in-flight, real-time sampling and analysis of CO2, CH4, and H2O in aircraft, ship, and similar environments. It is based on wavelength-scanned cavity ring down technology and withstands climb/descent rates to 1 km/min as well as associated vibration profiles. Sensor employs pressure and temperature stability and control technologies and does not require frequent re-calibration.
|
 Mass Emissions Monitor offers portable operation.E Instruments Group LLC
Langhorne, PA 19047
Feb 24, 2009
GreenLine 8000LBH simultaneously measures stack gas concentrations, velocity, and temperature to then calculate, record, graph, and report mass emissions in lb/hr for gases including CO, NO, NO2, True NOx, SO2, CO2, and H2S. It has low NOx and true NOx (NO+NO2) capabilities and offers CO sensor dilution with auto-ranging up to 10%. Other features include built-in peltier chiller with automatic water drain, heated probe and hose, and Bluetooth based remote control and display unit.
|
 Multi-Gas Analyzer targets air separation plants.Servomex Group Ltd
Crowborough East Su TN6 3DU United Kingdom
Dec 18, 2008
Available in benchtop, panel, or 19 in. rackmount options, SERVOPRO MultiExact provides 2 simultaneous measurements for O2 Purity, O2 Control, O2 Trace, CO2 Trace, and N2O Trace. Unit incorporates user-definable air point calibration function for O2 Trace and mA autoranging functionality. In addition to RS232 serial communications, analyzer offers NAMUR-compliant fault relay functions, allowing alarms, maintenance, and service-in-progress messages to be communicated remotely.
|
 Oxygen Gas Analyzer includes pressure compensation system.Servomex Group Ltd
Crowborough East Su TN6 3DU United Kingdom
Nov 10, 2008
In addition to fault and calibration histories, SERVOTOUGH Oxy offers NAMUR-compliant relay functions, allowing 2 concentration alarm levels, as well as maintenance required, service in progress, and instrument fault messages to be communicated remotely. Fully heated sample compartment removes requirement for sampling conditioning system on all samples with dew point up to 50°C. Located after measurement outlet, flow sensor guarantees accurate flow alarm settings.
|
Refinery Gas Analyzers offer high-speed operation.PerkinElmer, Inc., Life Sciences Headquarters
Boston, MA 02118
Aug 13, 2008
Based on PerkinElmerŪ ClarusŪ Gas Chromatograph, Models 1117 and 1317 incorporate column sets to accommodate use of hydrogen carrier gas to optimize throughput. Using 2 thermal conductivity detectors and flame ionization detector, Model 1117 provides analysis of helium, hydrogen, oxygen, nitrogen, CO2, CO, H2S, and C1 through C5 hydrocarbons in approximately 7.5 min. Model 1317 offers additional capability of sampling pressurized liquids through use of liquid sampling valve.
|
Cleanroom Analyzer continuously measures HF and HCl gasses.Tiger Optics, L.L.C.
Warrington, PA 18976-2426
Jul 30, 2008
Employing Continuous Wave Cavity Ring-Down Spectroscopy (CW-CRDS) technology, Tiger-i(TM) monitors cleanroom ambient air for gas phase airborne molecular contaminants that compromise manufacturing process quality and yield. It offers immediate, calibration-free analysis, measuring parts per trillion levels of trace hydrofluoride (HF) and hydrochloride (HCl) gases. Built-in reference cell and automated tune function provide 99.9% uptime without calibration, consumables, or maintenance.
|
Process Gas Analyzers utilize photometric technology.Emerson Process Management / Process Analytic Division
Solon, OH 44139
Jul 02, 2008
Able to perform 4 measurements in single enclosure, X-STREAMŪ Gas Analyzers feature IntrinzX(TM) technology, which uses split cell dual beam photometry and constant comparison of reference signal and measurement signal to achieve intrinsically linear response to changes in concentration. Technology enables sensitivity as low as 0-10 ppm, span drift less than 0.5% per week, and dynamic ranges as large as 0-200 to 50,000 ppm. NEMA 4X/IP66 and flameproof versions are available.
|
Process Gas Chromatograph is suited for ppb gas analysis.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
May 07, 2008
Optimized for ppb analysis of non-corrosive and corrosive gases such as air, Ar, and He, 19 in. rack mount compatible Series 200DID is computer controlled using keypad with vacuum fluorescence graphical display. It features 24/7 continuous, unattended operation, packed/micro-packed columns, automated valve control, isolated, discrete 4-20 mA outputs, and manual/automatic operation modes. Self-contained instrument eliminates need for any chromatography software.
|
Analyzer is optimized for corrosive/non-corrosive gases.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
Apr 22, 2008
Featuring built-in signal amplification and filament protection circuit, Series 100TCD offers application-specific system configurations for analysis of industrial and specialty gases used in various applications. Product is offered as 19 in. rack- or benchtop-mountable unit and incorporates flow system comprised of pneumatically controlled, automatic gas sampling valves; independent flow controls for each column; and laminar flow design.
|
HF Gas Analyzer features parts per trillion sensitivity.Picarro Inc.
Sunnyvale, CA 94085
Apr 17, 2008
Used for trace HF (hydrogen fluoride) detection, real-time gas analyzer can measure down to 10 ppt concentrations in ambient air and does not require frequent calibration. It is based on Wavelength-Scanned Cavity Ring Down Spectroscopy technology; offers cross-talk immunity from any other ambient gas component, including varying moisture levels; and can be operated remotely with sampling rates as fast 1 Hz, producing drift-free data with up to 4 digits of precision.
|
Hydrocarbon Analyzer features compact, lightweight design.MOCON
Minneapolis, MN 55428 1010
Apr 11, 2008
Measuring 19 x 14.25 x 5.25 in. and weighing less than 20 lb, Series 9000 Total Hydrocarbon Analyzer has active range from less than 10 ppb on high sensitivity version and up to 100% as methane on percent level version. Standard outputs include alarm and fault relays, 0-20 mA or 4-20 mA analog, or RS-232/Ethernet. FlowGuard electronic control of fuel/air and sample delivery to flame ionization detector, with automatic ignition, ensures safety.
|
 Gas Analyzer measures most gas species that absorb UV.AMETEK Process Instruments
Newark, DE 19702
Mar 21, 2008
Used alone or integrated into Continuous Emission Monitor (CEM) systems, Model 9000 RM single- or multi-component gas analyzer is supplied in 19 in., rack-mountable housing. It can be configured to measure most gas species that absorb UV, and optional low range white cell provides longer path length for measuring lower concentrations. Along with resolution of better than 0.02 nm, analyzer offers remote and local access to all parameters for graphing, logging, and trending.
|
Gas Analyzer pinpoints types and origins of CO2 emissions.Picarro Inc.
Sunnyvale, CA 94085
Feb 12, 2008
Designed for continuous measurement of Isotopic CO2, CRDS ultra-trace gas analyzers are based on cavity ring down spectroscopy (CRDS) technology and deliver ppb to ppt gas concentration sensitivity without interference. Drift- and maintenance-free products require no consumables and measure single spectral features in compact flow cell with effective path length of up to 12 km. Designed to run unattended for days in remote locations, instruments suited for field and laboratory use.
|
Dual Gas Analyzer offers alternative to gas chromatography.Sensor Electronics Corp.
Minneapolis, MN 55436
Dec 13, 2007
Utilizing IR, optical sensing technology, SEC DIR Analyzer measures 2 gases simultaneously in process environment. It can sense water vapor, CO2, hydrocarbons, and ethylene oxide, among others. Explosion-proof unit is self-correcting and can work for years without recalibration or adjustments. Operating over temperature, RH, and pressure extremes, analyzer is resistant to dust, dirt, and toxic/corrosive atmospheres. Self-diagnosing fail-safe design advises user of operating status.
|
Gas Analyzer measures trace amounts of nitrogen in argon.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
Dec 12, 2007
Offered in 3 variants, Series 1200 Gas Analyzer utilizes detection principle based on spectral emission of argon plasma. There are no valves, carrier gas, or radioactive source. Unit features non-depleting cell; online, continuous trending of nitrogen concentration with no need for sample injection or separation columns; and over-range protection. Ranges include Model 1200-A for 0-2/0-20 ppm, Model 1200-B for 0-20/0-200 ppm, and Model 1200-C for 0-10/0-100 ppm.
|
Process Gas Analyzers feature flameproof design.Emerson Process Management
Austin, TX 78754
Oct 01, 2007
Offering single- and dual-channel analysis, X-STREAM(TM) Analyzers utilize NDIR/UV/VIS photometry, paramagnetic and electrochemical oxygen, and thermal conductivity sensor technologies. Units include thermostatic control to measure low sample gas concentrations and high dew points. In addition to being intrinsically safe, measuring cells are resistant to solvents and corrosion. Analog and digital I/O, status signal relay outputs, and serial interface with Modbus communication are provided.
|