Advertisement
|
|
Test & Measuring Instruments ->
Analyzers ->
Chemical Analyzers ->
Emission Analyzers
Emission Analyzers
(Showing headlines 1 - 18)
|
Transient Emissions Tester is compliant to ISO 7637-2.Teseq, Inc.
Edison, NJ 08837
Aug 26, 2008
Model AES 5500 tests conducted electrical transient compatibility of equipment installed in passenger cars and light commercial vehicles fitted with 12 V electrical system or commercial vehicles fitted with 24 V electrical system. Its 100 A MC-type connectors are strategically placed and countersunk 50 mm above ground plane to allow for precise cabling. Separate control station is supplied for automatic, manual, or external triggering of switches.
|
EMC Immunity Test System has 9 kHz to 1 GHz frequency range.Teseq, Inc.
Edison, NJ 08837
Aug 01, 2008
Featuring substitution and closed loop test methods, NSG 4070 meets automotive industry standards for bulk current injection test methods, including ISO 11452-4. With modular set-up that utilizes internal/external amplifiers, it is also useful in non-automotive test labs and design departments for RF conducted immunity testing according to IEC 61000-4-6. Front panel of system includes 5.7 in. TFT color display, push buttons, USB port, and external access to signal generator output.
|
 Particulate Transmitter utilizes induction sensing.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Dec 05, 2007
Usable as dust collector emissions monitor and leak detector, standard Series PMT is designed for general maintenance planning and process protection applications. Adjustable linear or logarithmic output scaling enables trending of baseline and high peak emissions that are caused by filter cleaning cycles and developing leaks. Protective layers on probe work with induction-sensing to ensure reliable operation with all types of particulate.
|
Laser-Based Gas Analyzer offers emission monitoring.Cemtrex Inc.
Farmingdale, NY 11735
Sep 05, 2007
Eliminating need for transferring measuring gas to analyzer through chiller sampling system, Model ZSS Tunable Diode Laser (TDL) based laser gas analyzer facilitates continuous measurements of ammonia, hydrogen chloride, and nitrogen oxides in flue gases emitted from power plants and incinerators. It comes in dust-resistant construction and can be installed before bag filter where gas sampling could not be conducted previously.
|
 Oxygen Analyzer measures residual oxygen in flue gases.Emerson Electric Co.
St. Louis, MO 63136 8506
Jul 19, 2007
Integrating oxygen probe and field electronics into single, compact package, Rosemount® Analytical X-STREAM(TM) Oxygen Transmitter is suited for boilers, process heaters, kilns, and furnaces. Features include maximum flue gas temperature specifications to 850°C, ±75% accuracy of reading or ±.05 oxygen, calibration validity of more than .02%, adaptability to existing oxygen probe installations, 2-wire, loop-powered electronics, and advanced sensor diagnostics.
|
Emissions Model calculates company CO2 production levels.TRX, Inc.
Atlanta, GA 30329
Feb 20, 2007
Carbon Emissions Model provides corporations with empirical data detailing impact of employee travel on environment. With it, corporations can learn how much CO2 their specific global air travel program has emitted as well as how their program compares to industry averages. Model also provides tools to determine how changing preferred carriers or modifying travel volume would impact environment. Information is based on specific corporate travel footprint.
|
 Emissions Monitoring System offers 2-point stream switching.Emerson Process Management / Rosemount Div.
Chanhassen, MN 55317
Oct 20, 2004
MicroCEM(TM) TS field-mountable, continuous emissions monitoring system allows facilities to monitor 2 sample points/stacks with one analyzer system. Monitor extracts sample gas, conditions sample, analyzes sample for desired components, and processes emissions data by utilizing calibration validation calculations/procedures and oxygen diluent corrections. MicroCEM TS stores relevant raw/diluent corrected emissions, flags, calibrations, and alarms for 3 months.
|
 Protocol Emissions Analyzers offer step-by-step operation.TSI, Inc.
Shoreview, MN 55126-3996
Sep 29, 2004 With on-board CTM-34 test protocol, CA-CALCâ„¢ Series CA-6300 Compliance Protocol Emissions Analyzers guide operators through each step of combustion test process and print reports on-site. Products feature sample conditioner for hands-free, continual water removal and standard, low-maintenance emissions probe. Offered in 4 models, series also features factory-calibrated, field-replaceable sensors. |
 Gas Sampling System is probe mounted.Perma Pure Inc.
Toms River, NJ 08754
Jul 22, 2004 Designed to prepare wet, hot, and dirty stack gases for analysis, 1640 Mini-GASS (Gas Analysis Sampling System) allows users to accurately monitor smoke stack emissions. Gas conditioning system extracts sample gas via integrated sample probe and passes it through series of filters, scrubbers, and dryers. Housed in stainless steel cabinet, components remove water, acid mist, and ash without altering concentrations of gases to be analyzed. |
 Canister Conditioning System provides emissions testing.Sakor Technologies, Inc.
Okemos, MI 48864
Mar 12, 2004 ECS 3000â„¢ Canister Conditioning System meets EPA/CARB requirements for emission canister conditioning using butane/nitrogen procedures. It can execute simultaneous and independent multiple-canister operations. Purge/load module incorporates 2 independent butane loading stations, and system control console can be remotely located. Unit is capable of configurable data and alarm logging, test report generation, and temperature and humidity monitoring. |
 Particulate Analyzers are suited for in-use measurements.Sensors, Inc.
Saline, MI 48176
Nov 24, 2003 SEMTECH QCM (quartz crystal microbalance) and MPS (micro-proportional sampler) provide transient, mass measurement of particulate matter (PM) in engine exhausts. Former calculates mass of PM with resolution approaching 1 nanogram. SEMTECH MPS delivers response times of 0.1 sec and operational speeds of greater than 5 Hz. Based on Labview® platform, both are configurable for short, high-mass deposits or long-term sampling. |
 Emissions Analyzer measures oxides of nitrogen.Sensors, Inc.
Saline, MI 48176
May 22, 2003 SEMTECH NO/NO2 200 emissions analyzer provides accuracy within ±3% of reading, or 15 ppm, whichever is greater, for NO and NO2. Discreet spectral lines emitted by electrodeless lamp correspond to adsorption wavelengths for NO and NO2, eliminating need for NO2 to NO converter. Unit uses sophisticated control electronics and software with advanced algorithms. PC/104 computer allows addition or removal of hardware modules. |
 Emission Monitoring System is suited for stack flue gases.Ducon Technologies, Inc.
Farmingdale, NY 11735
Mar 19, 2003 Intelli-CEMS Continuous Emission Monitoring system measures SO2, CO, NOx, O2, and CO2. CEMS consists of Insitu Probe type multi-gas analyzers, By-pass Extractive analyzers, Gas Velocity Monitors, and DAQ and EPA reporting software; all with dynamic online zero and span verification and remote diagnostics access. COMS consists of laser-based, path-independent opacity monitor, which is vibration resistant and has zero pipe fiber optic technology. |
 Emissions Analyzer tests gasoline engines in real-time.Sensors, Inc.
Saline, MI 48176
Nov 18, 2002 SEMTECH-G simultaneously measures and records vehicles' tailpipe emissions and on-board electronic control systems output while vehicle is driven. It provides immediate analysis of exhaust gas components and is accurate to ±3% of reading when reporting concentrations for NO, CO, CO2, and THC. Mass measurements are calculated using information from vehicles' ECMs in g/mi. Measuring 22 x 17 x 14, unit is rack mountable and suits on- and off-road applications. |
 Diesel Emissions Analyzer provides real-time data.Sensors, Inc.
Saline, MI 48176
Sep 05, 2002 SEMTECH-D enables diesel vehicle's tailpipe emissions and output of on-board electronic control system to be measured and recorded simultaneously while being driven on road. When reporting concentrations for NO, NO2, CO, CO2, and THC exhaust constituents, accuracy, resolution, and detection limits are 3-4%. Reporting is in g/Bhp-hr or g/mile on electronically controlled engines. For engines without electronic controls, additional instrumentation is needed.
|
 Emissions Analyzer is powered by rechargeable battery.Crowcon Detection Instruments
Milford, OH 45150
Jun 07, 2002 Tempest 100 handheld analyzer monitors gaseous emissions, calculates combustion efficiency, and logs and prints gas data. Detectable gases include CO, CO2, nitrogen monoxide, and O2. All data can be downloaded to PC. Tempest 100 also provides unattended monitoring over extended periods via programmable datalogging. It analyzes combustion performance with integral thermocouples, which measure inlet, stack, and ambient temperature. |
 Stack Moisture Monitor meets EPA requirements.MAC Instruments, A Div. Of Machine Applications Corp.
Sandusky, OH 44870
Mar 08, 2002 MAC 150 high temperature moisture analyzer continuously monitors emission stack gases. It meets EPA and local regulatory requirements for 2-point daily calibration check and 3-point linearity check. Unit measures 5 to 25% percent moisture by volume at temperatures up to 2400 deg F, eliminating percent moisture estimates based on wet and dry O2 measurements. Internal calibrator allows automatic calibration checks or in situ recalibration.
|
 Flue Gas Analyzer checks oxygen and carbon monoxide.Nova Analytical Systems Inc.
Niagara Falls, NY 14301 2398
Nov 09, 2001 Portable Model 360 measures oxygen and CO present in flue gas sample. It uses customer replaceable sensors, which have life expectancy of 2-3 years. Analyzer is complete with built-in sample pump, 12 ft of sample hose, filter/condensate trap, flowmeter, rechargeable gel cell battery, LCD digital readouts, and temperature sensor. It indicates stack temperature for fuel efficiency calculations. Efficiency charts for each fuel are provided.
|
(Showing headlines 1 - 18)
|
|
|