(Showing headlines 1 - 20) more ....
|
Bulk Material Analyzers monitor moving material in real time.SABIA, Inc.
San Diego, CA 92128
Nov 10, 2009
SABIA X1 Series on-belt elemental analyzers provide accurate elemental analysis of moving stream of material. They mount onto existing conveyor structures without modifications and are network compatible, enabling users to view analysis results in real time from any web browser. Adaptable for coal, cement, and minerals applications, analyzers can be customized according to configuration and readout format for specific application.
|
Testing System combines sulfur, nitrogen, and halide detection.PAC Petroleum Analyzer Company L.P.
Pasadena, TX 77503
Oct 09, 2009
Compact, automated, and multi-configurable ANTEK MultiTek(TM) is one testing system capable of detection and analysis of unwanted chemicals, pollutants, contaminants, and corrosive elements. Specifically, it detects sulfur, nitrogen, and halides through process that includes combustion Ion Chromatography, Ultraviolet Fluorescence, and Chemiluminescence technologies. This platform works with solid, liquid, gas, and LPG samples.
|
 Gas Monitors help detect or monitor hydrogen peroxide.Interscan Corp.
Chatsworth, CA 91313
Jun 09, 2009
Offered in range of portable survey monitors to permanently installed multipoint systems, hydrogen peroxide monitoring instruments feature full data acquisition, archiving, and reporting capability. Products come with minimum detectability of 0.05 ppm, and full scale ranges up to 0-1,000 ppm. Suitable applications include sterile processing departments and bio-decontamination in health care industry.
|
 Mercury Analyzer offers 50 ppt determination limit.JM Science, Inc.
Grand Island, NY 14072-0250
Jun 04, 2009
Measuring 220 x 400 x 220 mm, AQUACOUNTER® HG-400 mercury analyzer is equipped with large color touch panel screen and comes with built-in printer. Lower detection limit is 0.5 ppt for sample volume 5 mL and 5 ppt for sample volumes 20, 100, and 250 mL. Sample solutions of size 5, 20, 100, and 250 mL can be accommodated by adding optional components. Applications include mercury analysis in effluent treatment, food, and ambient water.
|
 Mercury Analyzer facilitates contamination testing.PerkinElmer, Inc.
NORFOLK, MA 02181
Apr 17, 2009
Designed to optimize detection and measurement of mercury in solids and liquids, Model SMS 100 helps minimize need for complex sample preparation. Automated analyzer employs thermal decomposition, gold amalgamation, and cold vapor atomic absorption spectrometry. With detection limits as low as 1 ppt, unit enables environmental laboratories, municipalities, power utilities, waste producers, and food companies to comply with various regulations and protect consumers.
|
Flare Analyzer helps refineries meet EPA emissions regulations.Thermo Fisher Scientific
Waltham, MA 02454
Feb 23, 2009
Offered as solution for refineries and related facilities seeking to meet new EPA sulfur emission regulations, SOLA II Flare(TM) is single analyzer system for continuous monitoring of sulfur emissions. It offers dynamic measurement range of 10 ppm to 95 percent of volume, enabling determination of exact amount of sulfur emitted as well as the duration of flaring event. SOLA II Flare enables actual sulfur quantities to be recorded, even at very low levels.
|
 Total NSX Analyzer has compact, modular design.Thermo Fisher Scientific
Waltham, MA 02454
Jan 14, 2009
With working range that covers total Nitrogen/Sulfur/Chlorine (NSX) from low-ppb to high-ppm concentrations, TITAN 4000 uses combustion method that caters to range of applications in refinery and chemical samples. Operation is in real-time, with TN/TS samples analyzed within 2 min and TX samples under 4 min, and requires minimal handling. Also included, chromium-plated copper spray injection design can inject high-boiling point component samples without blocking injection system.
|
 Mercury Analyzer has color touch panel screen.JM Science, Inc.
Grand Island, NY 14072-0250
Dec 15, 2008
Available with built in printer, AQUACOUNTER® HG-400 mercury analyzer can accomodate 4 different sizes of sample solutions; 5, 20, 100, and 250 mL. With footprint of 220 x 400 x 220 mm, unit has lower detection limit of 0.5 ppt in a sample vol of 5 mL, 5 ppt in sample vols of 20, 100, 250 mL. Determination limit is 50 ppt.
|
 Gas Chromatograph detects sulfur and VOC in natural gas.Photovac Inc.
Waltham, MA 02451 1166
Oct 28, 2008
Voyager Portable Gas Chromatograph offers on-site capability for measuring critical sulfur species to establish sulfur and VOC content in natural gas, thereby allowing production companies to determine corrective measures for scrubbing and removal of contamination. Datalogging capability enables readings to be stored in instrument and downloaded to computer for analysis and recordkeeping. Voyager is intrinsically safe for operations in hazardous environments.
|
XRF Spectrometer features motorized turret.EDAX, Inc.
Mahwah, NJ 07430
Sep 02, 2008
Available with mono-capillary optics or as a PC with high-intensity poly-capillary optic, Orbis micro-XRF elemental analyzer incorporates motorized turret that integrates video and x-ray optics for coaxial sample view and x-ray analysis over rough sample topography without sacrificing signal intensity. Users can make elemental analyses on small samples such as particles, fragments, and inclusions, or conduct automated multi-point and elemental imaging analysis on larger samples.
|
HF Gas Analyzer features parts per trillion sensitivity.Picarro Inc.
Sunnyvale, CA 94085
Apr 17, 2008
Used for trace HF (hydrogen fluoride) detection, real-time gas analyzer can measure down to 10 ppt concentrations in ambient air and does not require frequent calibration. It is based on Wavelength-Scanned Cavity Ring Down Spectroscopy technology; offers cross-talk immunity from any other ambient gas component, including varying moisture levels; and can be operated remotely with sampling rates as fast 1 Hz, producing drift-free data with up to 4 digits of precision.
|
 Sulfur Analyzer helps improve refinery efficiency.Thermo Fisher Scientific
Waltham, MA 02454
Nov 30, 2007
Total Sulfur (TS) 4000 incorporates True Total Sulfur (TTS) technology, which removes nitrogen interference in order to provide accurate results and can determine trace level sulfur in Cetane Improver. Suited for range of refinery and petroleum sample types with high nitrogen concentration, analyzer is configured with UV-F detection system and is capable of detecting sulfur in liquids, solids, and gas samples. NeXYZ liquid autosampler is also included.
|
Handheld XRF Analyzers help support government regulations.Thermo Fisher Scientific
Waltham, MA 02454
Jul 31, 2007
Providing optimized excitation of elements, NITON® XL3 Series uses NITON Data Transfer software to preserve and protect data from each sample analysis. Model 800 can take measurements on operating units in excess of 800°F for alloy analysis. Providing RoHS and WEEE compliance, Model 700 performs rapid simultaneous measurement of up to 25 elements in sample. Model 500 can identify new mine sites, while Model 600 helps identify pollution boundaries at sites of industrial contamination.
|
Muli-Component Analyzer measures total sulfer in 2 ways.Applied Analytics, Inc.
Concord, MA 01742
Jul 05, 2007
Insusceptible to component cross-interference, TSA-100 provides accurate total sulfur measurements when interfering compounds - H2S, SO2, and mercaptans - are present in sample. Analyzer, capable of direct or standard sampling, is comprised of xenon light source, flow cell, holographic grating, and diode array detector. Using full high-resolution spectrum, solid-state unit can switch between wavelength ranges to provide instantaneous and continuous measurements at 0-10 ppm and 0-100%.
|
Analyzer measures oxygen, nitrogen, and hydrogen.Horiba Jobin Yvon Inc.
Edison, NJ 08820
Jun 12, 2007
Model EMGA 620W/SP is combination of O2/N analyzer and H analyzer using same extraction furnace, balance, and computer system. It uses standard conventional methods for analysis of extracted gases and controls all operating and analysis modes. O2 is determined using IR detector, while N and H are measured using thermal conductivity detectors. Product allows either helium or argon gas to be selected, and applies constant purge flow during measurement.
|
Oxygen Analyzer handles samples up to 135°C.Servomex Group Ltd
Crowborough East Su TN6 3DU United Kingdom
Jun 22, 2006
Designed to complement 2200 Series process oxygen analyzers, 2200H transmitter withstands sample temperatures up to 135°C, eliminating need to condense hot sample prior to analysis. It measures oxygen content from 0-100% with response time of less than 4 sec. Approved for use in ATEX category 2 applications, transmitter is certified intrinsically safe and sealed to IP66/NEMA 4X. Up to six 2200H transmitters can be linked to single Servomex 2200 control unit.
|
O2 Averaging System suits large combustion applications.Emerson Process Management / Rosemount Div.
Chanhassen, MN 55317
May 02, 2006
Rosemount® Analytical OxyBalance(TM) enables users to set optimized fuel-to-air ratios and balance individual or sets of burners. Unit graphically displays up to 8 autonomous O2 measurements and provides variable time-scale trends for each probe value. From these readings, system generates up to 4 programmable O2 averages with any failed or calibrating probes data automatically removed from average. System is compatible with any O2 probe system with a 4-20 mA signal ouput.
|
 Material Analyzers help meet RoHS and WEEE requirements.Fischer Technology Inc.
Windsor, CT 06095
Apr 18, 2005 XAN and XDAL instruments measure toxic metals in plastics to meet EU directives RoHS and WEEE, which state that electronic goods and waste may only contain lead, cadmium, mercury, chromium, and bromine up to legally permitted limit. XAN provides results within 30 sec, while XDAL system is suited for programmed measurements of several samples or scanning of larger specimens. Both instruments contain integrated video microscope. |
Spectrometer System detects most elements in periodic table.Ocean Optics, Inc.
Dunedin, FL 34698
Apr 12, 2005 Laser-induced LIBS-ELITE provides real-time spectral analysis of elements in variety of materials. It covers 200-980 nm spectral range at 0.1 nm in single laser pulse. System includes 1,064 nm Nd:YAG laser, sample mapping and targeting functions, X-Y sample positioning, laser spot diameter control from 20 µm to 1,200 µm, sample magnification, and sample chamber with gas purge. Open-architecture housing accommodates sample sizes up to 4 in. in dia. |
 Elemental Determinator offers optional liquid autosampler.Leco Corp.
St. Joseph, MI 49085 2396
Mar 15, 2005 TruSpec® Elemental Determinator utilizes DI-PAL Liquid Autosampler for seamless automation of liquid analysis. Autosampler kit is recommended for applications with low viscosity such as waters, beverages, slurries, urea, and light oils. It includes everything needed to mate to TruSpec, in addition to necessary software updates. TruSpec is available in choice of Nitrogen, combined Carbon/Nitrogen, and simultaneous Carbon/Hydrogen/Nitrogen configurations. |