Multiparameter Analyzers offer digital communications.Emerson Process Management / Process Liquid Division / Uniloc Division
Irvine, CA 92606
May 16, 2008
Rosemount Analytical® Model 1056-HT and 1056-DP are 4-wire, dual-input analyzers that feature, respectively, complete HART® and Profibus® DP digital communications. HART-enabled analyzer allows remote calibration, continuous monitoring of 4 live process variables, and configuration from AMS® Suite or DeltaV(TM) host applications, legacy DCS, or SCADA systems. Diagnostics allows plants to estimate life of in-process sensors and perform required maintenance on timely basis.
|
Process Gas Chromatograph is suited for ppb gas analysis.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
May 07, 2008
Optimized for ppb analysis of non-corrosive and corrosive gases such as air, Ar, and He, 19 in. rack mount compatible Series 200DID is computer controlled using keypad with vacuum fluorescence graphical display. It features 24/7 continuous, unattended operation, packed/micro-packed columns, automated valve control, isolated, discrete 4-20 mA outputs, and manual/automatic operation modes. Self-contained instrument eliminates need for any chromatography software.
|
Laser Beam Profiler handles up to 48 images/sec in real-time.Ophir-Spiricon Inc.
Logan, UT 84321
May 01, 2008
Enabling quantitative measurement and viewing of CO2 beams, II-VI-CO2-58 Industrial Laser Beam Analyzer diagnoses faults and corrects issues related to beam stability, alignment, tuning, and optimization. With ability to handle up to 10 kW of power, portable device features 58 mm clear aperture that enables users to measure large laser beams. Laser beam profiling system is designed to work with Pyrocam(TM) III beam profiling camera that delivers 1,000:1 linear dynamic range.
|
 FTIR Spectrometers enable on-site lubrication analysis.A2 Technologies, LLC
Danbury, CT 06810
Apr 29, 2008
Designed for lubrication analysis in various power industry systems, PAL instruments quantify water levels from 50-5,000 ppm in oils with accuracy of better than 5%. Products utilize Fourier Transform Infrared (FTIR) method, which requires no hazardous reagents. In addition to measuring water level, systems immediately yield amount of oxidation and nitration byproducts present as well as amount of anti-oxidation, anti-wear, and extreme pressure additives that remain in lubricant.
|
Transfection System speeds cell-based assay development.MaxCyte, Inc
Gaithersburg, MD 20878
Apr 23, 2008
Used for reagent-free preparative transfection based on flow electroporation technology, ITF Inline Transfection System is sterile, closed system available for drug discovery and screening applications. Validated and scalable platform enables transient transfection of any kind of cell or cell line with any molecule at scales ranging from micro-liters to liter volumes. It can be used to transfect 105-107 cells in seconds and up to 1010 cells in under 30 min.
|
Analyzer is optimized for corrosive/non-corrosive gases.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
Apr 22, 2008
Featuring built-in signal amplification and filament protection circuit, Series 100TCD offers application-specific system configurations for analysis of industrial and specialty gases used in various applications. Product is offered as 19 in. rack- or benchtop-mountable unit and incorporates flow system comprised of pneumatically controlled, automatic gas sampling valves; independent flow controls for each column; and laminar flow design.
|
HF Gas Analyzer features parts per trillion sensitivity.Picarro Inc.
Sunnyvale, CA 94085
Apr 17, 2008
Used for trace HF (hydrogen fluoride) detection, real-time gas analyzer can measure down to 10 ppt concentrations in ambient air and does not require frequent calibration. It is based on Wavelength-Scanned Cavity Ring Down Spectroscopy technology; offers cross-talk immunity from any other ambient gas component, including varying moisture levels; and can be operated remotely with sampling rates as fast 1 Hz, producing drift-free data with up to 4 digits of precision.
|
Hydrocarbon Analyzer features compact, lightweight design.MOCON
Minneapolis, MN 55428 1010
Apr 11, 2008
Measuring 19 x 14.25 x 5.25 in. and weighing less than 20 lb, Series 9000 Total Hydrocarbon Analyzer has active range from less than 10 ppb on high sensitivity version and up to 100% as methane on percent level version. Standard outputs include alarm and fault relays, 0-20 mA or 4-20 mA analog, or RS-232/Ethernet. FlowGuard electronic control of fuel/air and sample delivery to flame ionization detector, with automatic ignition, ensures safety.
|
 Gas Analyzer measures most gas species that absorb UV.AMETEK Process Instruments
Newark, DE 19702
Mar 21, 2008
Used alone or integrated into Continuous Emission Monitor (CEM) systems, Model 9000 RM single- or multi-component gas analyzer is supplied in 19 in., rack-mountable housing. It can be configured to measure most gas species that absorb UV, and optional low range white cell provides longer path length for measuring lower concentrations. Along with resolution of better than 0.02 nm, analyzer offers remote and local access to all parameters for graphing, logging, and trending.
|
Work Cell targets chemistry testing market.Beckman Coulter, Inc.
Fullerton, CA 92834-3100
Mar 13, 2008
Consolidating chemistry and immunoassay testing targeted to high-volume laboratories, UniCel DxC 880i Synchron® Access® clinical system offers menu of more than 150 different chemistry and immunoassay tests, with 120 onboard. System can process up to 1,440 chemistry and 400 immunoassay tests/hr, respectively. It features closed-tube sampling and closed-tube aliquotting capabilities to eliminate de-capping and re-capping steps in laboratory process.
|
Water Vapor Analyzer provides continuous, in-situ operation.Picarro Inc.
Sunnyvale, CA 94085
Mar 11, 2008
Deployed in field or laboratory, Isotropic Water Vapor Analyzer measures oxygen and hydrogen isotopes in water vapor. Device measures single spectral features in flow cell with effective path length up to 12 km. High resolution and resulting specificity enable analyzer to discriminate between closely spaced spectral lines arising from different isotopic compositions in sample gas. Instrument is suited for source of origin monitoring, as well as water cycle and climate studies.
|
Water Tester enables precise and accurate analysis.Industrial Test Systems, Inc.
Rock Hill, SC 29730
Mar 07, 2008
Featuring built-in sample cell/cuvette, eXact® EZ Advanced Photometric System eliminates handling of cells to promote precision while also eliminating aggravation of lost/broken cells. Reagent delivery device, eXact® Strip, allows simultaneous introduction of reagents that must normally be kept segregated. Accurate to 0.01 mg/L, meter offers 25+ parameters for analysis and is designed to minimize test time. Meter cell capacity is 10 mL.
|
Gas Analyzer pinpoints types and origins of CO2 emissions.Picarro Inc.
Sunnyvale, CA 94085
Feb 12, 2008
Designed for continuous measurement of Isotopic CO2, CRDS ultra-trace gas analyzers are based on cavity ring down spectroscopy (CRDS) technology and deliver ppb to ppt gas concentration sensitivity without interference. Drift- and maintenance-free products require no consumables and measure single spectral features in compact flow cell with effective path length of up to 12 km. Designed to run unattended for days in remote locations, instruments suited for field and laboratory use.
|
 Dissolved Ozone Analyzer targets USP and ultrapure water applications.IN USA, Inc.
Needham, MA 02494
Jan 24, 2008
Able to read and measure low concentrations of dissolved ozone at ppb level, dFFOZ-TR Trace Dissolved Ozone Analyzer is suited for measuring residual ozone in predestruct and postdestruct water loops. Drift-free device utilizes UV light absorption technology and is immune to cross-interference from other gases. Protected in NEMA 4X enclosure, it features replaceable UV lamp that provides service life up to 18 months.
|
O2 Analyzer maintains accurate oxygen measurements.Emerson Process Management
Austin, TX 78754
Jan 17, 2008
X-STREAM(TM) O2 analyzer incorporates AccuMax(TM) technology that increases boiler and furnace efficiency and reduces emissions. Analyzer includes internal mechanical assembly that stabilizes cell temperature, increasing oxygen measurement accuracy. Also incorporated is Calibration-Recommended Diagnostic which identifies when probe requires calibration, eliminating need to do calibrations on periodic basis.
|
FTIR Systems enable in situ monitoring of chemical reactions.Mettler Toledo, Inc.
Columbus, OH 43240
Jan 10, 2008
Entry level ReactIR(TM) 15m is suited for organic chemist who needs chemical information, while high end ReactIR(TM) 45m is tool for chemical engineers and technologists who focus on process optimization and characterization. Designed for monitoring reactions that involve nitriles, ketenes, metal carbonyls, or isocyanates, SiComp AgX FiberConduit(TM) is silicon-based ATR sensor integrated with AgX fiber technology.
|
Dual Gas Analyzer offers alternative to gas chromatography.Sensor Electronics Corp.
Minneapolis, MN 55436
Dec 13, 2007
Utilizing IR, optical sensing technology, SEC DIR Analyzer measures 2 gases simultaneously in process environment. It can sense water vapor, CO2, hydrocarbons, and ethylene oxide, among others. Explosion-proof unit is self-correcting and can work for years without recalibration or adjustments. Operating over temperature, RH, and pressure extremes, analyzer is resistant to dust, dirt, and toxic/corrosive atmospheres. Self-diagnosing fail-safe design advises user of operating status.
|
Gas Analyzer measures trace amounts of nitrogen in argon.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
Dec 12, 2007
Offered in 3 variants, Series 1200 Gas Analyzer utilizes detection principle based on spectral emission of argon plasma. There are no valves, carrier gas, or radioactive source. Unit features non-depleting cell; online, continuous trending of nitrogen concentration with no need for sample injection or separation columns; and over-range protection. Ranges include Model 1200-A for 0-2/0-20 ppm, Model 1200-B for 0-20/0-200 ppm, and Model 1200-C for 0-10/0-100 ppm.
|
 Particulate Transmitter utilizes induction sensing.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Dec 05, 2007
Usable as dust collector emissions monitor and leak detector, standard Series PMT is designed for general maintenance planning and process protection applications. Adjustable linear or logarithmic output scaling enables trending of baseline and high peak emissions that are caused by filter cleaning cycles and developing leaks. Protective layers on probe work with induction-sensing to ensure reliable operation with all types of particulate.
|
 Sulfur Analyzer helps improve refinery efficiency.Thermo Fisher Scientific
Waltham, MA 02454
Nov 30, 2007
Total Sulfur (TS) 4000 incorporates True Total Sulfur (TTS) technology, which removes nitrogen interference in order to provide accurate results and can determine trace level sulfur in Cetane Improver. Suited for range of refinery and petroleum sample types with high nitrogen concentration, analyzer is configured with UV-F detection system and is capable of detecting sulfur in liquids, solids, and gas samples. NeXYZ liquid autosampler is also included.
|