Quantcast
 
Search for: Search what?
Nov 9, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Test & Measuring Instruments -> Analyzers -> Others


Others


   Add to Google      PDF icon



(Showing headlines 1 - 20)   more ....
Residual Gas Analyzers feature web-enabled design.

Residual Gas Analyzers feature web-enabled design.

MKS
Andover, MA 01810 2449
Oct 23, 2009 Featuring optimized electronics platform for data acquisition, Microvision 2 and e-Vision 2 offer stability for e-diagnostic, process monitoring, and general vacuum trouble-shooting applications. Ethernet connectivity enables users to access data from anywhere on TCP-IP network, providing solution to wide-scale multi-RGA installations. RGAs are available with variety of software control systems, including built-in web application, recipe-driven Process Eye Professional, and TOOLweb RGA.

High-Voltage Differential Probes offer 10:1 attenuation.

High-Voltage Differential Probes offer 10:1 attenuation.

Agilent Technologies, Inc
Santa Clara, CA 95051
Oct 16, 2009 With ability to provide general-purpose differential signal measurements, Agilent N2792A and N2793A differential probes have input resistance of 1 MW (for N2792A) and 200 kW (for N2793A) and low input capacitance of 3.5 pF (for N2792A) and 1 pF (for N2793A) to minimize circuit loading. It can be powered by USB port on scope or computer, or 9 V internal battery. They are compatible with any oscilloscope with 50 W BNC input.

Zeta Potential Measurement Cell handles concentrated samples.

Zeta Potential Measurement Cell handles concentrated samples.

Malvern Instruments Ltd
Malvern Worcestershire WR14 1XZ  United Kingdom
Oct 02, 2009 Designed for Zetasizer Nano particle characterization system, ZEN1010 enables measurement in samples up to 40% w/v. Design incorporates minimized optical path length and takes just 150 µl sample in measurement area. Although it operates as standard cell, ZEN1010 allows zeta potential measurements in highly concentrated samples. By requiring less sample dilution, it supports optimized maintenance of pH and chemical structure of sample for directly relevant zeta potential measurement.

XRF System measures thickness of photovoltaic depositions.

XRF System measures thickness of photovoltaic depositions.

Solar Metrology
Holbrook, NY 11714
Sep 28, 2009 Utilizing X-ray fluorescence, it-situ System SMX-ISI provides composition and thickness measurements for thin film solar PV metal film stacks on flexible roll to roll substrates such as stainless steel, aluminum, and polyimide or rigid substrates such as float glass. Typical measurement applications include Mo thickness and all CIGS combinations. System can be integrated into any vacuum deposition tool, vacuum process station, or point of vacuum process line.

Signal Analyzer suits high channel count applications.

Signal Analyzer suits high channel count applications.

IOtech, Inc.
Bedford Heights, OH 44146-1833
Sep 08, 2009 Providing 20 input channels with direct integrated electronic piezoelectric (IEPE) support, USB-based 672u offers ±40 V input range and can accommodate variety of analog input types including accelerometer, velomiter, proximity probe, microphone, or tachometer. Each analog input features 24-bit delta sigma ADC. Including 4 mA bias current with AC coupling for IEPE sensors, product suits rotating machine analysis, predictive maintenance, and modal analysis applications.

Mass Spectrometer occupies just 73 cm of bench space.

Agilent Technologies, Inc
Santa Clara, CA 95051
Aug 18, 2009 Suited for complex samples such as food, wastewater, and soil digests, Series 7700 Inductively Coupled Plasma - Mass Spectrometer trace element analyzer utilizes redesigned ion lens to minimize background noise across mass range. Octopole Reaction System, featuring helium collision mode, provides interference removal, especially for complex and unknown sample types. ICP-MS MassHunter software offers Expert Autotune, One Click Plasma Setting, and Batch-at-a-Glance real-time data review.

PCM Channel Analyzer is multi-functional and portable.

GAO Tek Inc.
Toronto M1B2K4  Canada
Jul 28, 2009 Used for measuring PCM devices, digital switches, carrier wave communication devices, and VoIP devices, model 2038 features high resolution color LCD, flexible control modes, and Windows style interface. It supports equal step sequence of frequency spots or customized spots where number of spots is selectable. With remote control via USB or Ethernet interface, device allows users to develop and design voice channel measurement/control systems under variety of different conditions.

Multi-channel Analyzer works with scintillation detectors.

Multi-channel Analyzer works with scintillation detectors.

AMETEK, Advanced Measurement Technology, Inc.
Oak Ridge, TN 37831-0895
Jul 27, 2009 Completely operable without PC, DigiDART-LF provides users with portable SMART multi-channel analyzer for sodium iodide, lanthanum bromide, and other scintillation detectors. Various measurements can be performed directly in-field or on-site, and internal memory stores spectra. Built-in LCD and control keypad create live display as data is acquired, while design promotes digital stability, optimized data throughput rates, and up to 12 hr of operation from one battery charge.

XRD/XRF Analyzer performs solid fat content (SFC) analysis.

XRD/XRF Analyzer performs solid fat content (SFC) analysis.

inXitu Inc.
Mountain View, CA 94043
Jul 22, 2009 Capable of measuring 3 distinct polymorphic TGA phases; alpha, beta, and beta-prime, BTX benchtop XRD/XRF analyzer can be positioned close to production process for resolution of issues arising when changing process parameters or raw materials. Based on simultaneous collection of X-ray pattern, system analyzes and identifies key phases in just 30 sec. Analyzer is suited for manufacturers of edible fats such as margarine, shortening, chocolate, cakes, candies, muffins, and biscuits.

Multi-Channel Analyzer operates without PC.

AMETEK, Advanced Measurement Technology, Inc.
Oak Ridge, TN 37831-0895
Jul 06, 2009 Designed for sodium iodide, lanthanum bromide, and other scintillation detectors, rugged, lightweight DigiDART-LF can perform variety of measurements directly in field or on site and store large amount of spectra in internal memory. It has built-in backlit LCD and control keypad to create live display as data is acquired. Featuring low-power design, unit provides digital stability, high data throughput, and up to 12 hr of operational life from single battery charge.

Instruments can be configured with up to 6 test positions.

Koehler Instrument Co., Inc.
Bohemia, NY 11716
Jun 30, 2009 Automated Low Temperature Instruments, integrated with panel PC, display and graph all analytical parameters in real-time on 6.4 in. TFT/LCD touch screen display with 640 x 480 resolution. Also, all information displayed on screen is recorded in MS Excel-compatible file format. Included software package monitors operation and performance of all analyzer components to ensure accurate data measurement. Direct cooling system, 1- or 2-stage, reaches low temperatures in ~15 min.

XRD/XRF Instrument is suited for art conservation analysis.

inXitu Inc.
Mountain View, CA 94043
Jun 08, 2009 Designed as portable, combined XRD/XRF instrument, Duetto is used for phase/mineral and elemental identification of delicate materials (such as art work) or items too large to be brought into laboratories. This non-destructive analysis tool allows x-ray diffraction and fluorescence data to be obtained from one location on artifact, without touching it. Applications include paintings, manuscripts, and sculptures.

Gas Analyzers measure trace impurities in argon.

GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
May 08, 2009 Utilizing high frequency argon discharge ionization detector, Models AR710 and AR720 analyze trace impurities, such as H2, N2, O2, CH2, CO, and CO2 in argon down to ppb range. Features include laminar low volume flow system, hands-free operation, VCR® fittings to ensure leak-free connections, and mass-spec leak tested valves. Analyzers are available with options such as 4-20 mA output, auto zero, and either bench mounted or 19 in. rack mounted for panel installation.

Turbidity Analyzer utilizes multi-beam sensing technology.

Turbidity Analyzer utilizes multi-beam sensing technology.

Electro-Chemical Devices, Inc.
Yorba Linda, CA 92887
May 05, 2009 Triton TR8 Turbidity Analyzer has optical assembly with 3 light beams and sensor electronics that adjust turbidity signal readings according to reference detector. Digital filter helps to suppress potentially interfering signals while self-monitoring diagnostics assure reliability. It features 880 nm LED light source, 2 nonvolatile memory banks, transmitter with 4-20 mA output, and controller with up to 2 outputs and 4 SPDT relays. Operating temperature range is 20-120°F.

Benchtop XRD/XRF Instrument suits laboratory-based analysis.

Benchtop XRD/XRF Instrument suits laboratory-based analysis.

inXitu Inc.
Mountain View, CA 94043
Apr 27, 2009 Model BTX combination x-ray diffraction, x-ray fluorescence instrument performs mineral/phase identification and quantification for routine quality control applications. Data can be collected regardless of grain size, with sizes up to 400 µm being tested producing data normally obtained with micron size particles. Unit's powder handling methods optimize quality of XRD data while minimizing sample preparation requirements.

Car Park System is compliant with German regulation VDI2053.

Industrial Scientific Corp.
Oakdale, PA 15071 1500
Apr 21, 2009 Providing option of 4 or 8 relay output modules, CPS Car Park System is 8 channel digital controller designed to regulate and monitor ambient air in underground parking facilities and tunnels. It can be configured to monitor from 1-256 modules up to 3,000 ft away from controller with 6 smart transmitter options. Several sensor options including CO, NO, NO2, CH4, LPG, and H2 can monitor wide range of hazards emitted by gasoline, natural gas, diesel-powered, and electric vehicles.

Handheld XRF Analyzer exceeds CPSIA requirements.

Handheld XRF Analyzer exceeds CPSIA requirements.

Eastern Applied Research, Inc.
Lockport, NY 14094
Mar 27, 2009 Used for detecting lead (Pb) content to meet regulations such as RoHS and Consumer Product Safety Improvement Act (CPSIA), Quick-Shot XRF can also perform precious metal analysis and alloy identification. Testing method is not limited by product size or location, and detection reaches below parts-per-million (ppm) levels determined hazardous in CPSIA regulation. Removable PDA offers immediate review of results, which may be transferred to any computer via Bluetooth.

XRF Glass Panel Sampling Tool suits CIGS/CdTe PV panel film.

XRF Glass Panel Sampling Tool suits CIGS/CdTe PV panel film.

Solar Metrology
Holbrook, NY 11714
Mar 06, 2009 Featuring 600 x 1,200 mm lateral X/Y range of measurement, SMX-FPV is designed for near-line film composition and thickness control of CIGS and CdTe film stacks. It also provides process control of active, contact, and TCO layers. Detailed analysis of full photovoltaic panels is possible, including copper and gallium ratio determination as well as panel gradient analysis. Areas of use include research and process development, in-process monitoring, and post-process QC.

XRF Analyzer combines Si-PIN detector, 40 kV X-ray tube.

XRF Analyzer combines Si-PIN detector, 40 kV X-ray tube.

Qualitest International Inc
Fort Lauderdale, FL 33308
Mar 05, 2009 Designed for on-site analysis, EDX Pocket III Handheld X-Ray Fluorescence (XRF) Spectrophotometer features electronically refrigerated Si-PIN detectors that eliminate need for liquid nitrogen and allow standalone use in temperatures from -4 to +122°F. Product, available with software packages for different application fields, provides laboratory-quality analysis of high- and low-alloy steel, minerals, precious metals, RoHS elements, and soil as well as light elements.

Analyzer measures properties of polymer and rubber compounds.

Analyzer measures properties of polymer and rubber compounds.

Qualitest International Inc
Fort Lauderdale, FL 33308
Mar 02, 2009 Advanced dynamic mechanical rheological test instrument, RPA 8000 Rubber Process Analyzer can measure properties of polymer and rubber compounds prior to, while, and after curing. It has range of oscillation angle, oscillation frequency, torque, and temperature, and can read differences in rheological, rheometric and dynamic viscoelastic properties of tested material. Compliant with ASTM D6204, D5289 and D6601, product includes software with pre programmed test methods.




(Showing headlines 1 - 20)   more ....



 Latest Products in the News


Thermo Fisher Scientific, Air Quality Instruments  - April 30, 2009
Thermo Fisher Scientific ICP Instrumentation Selected by Borregaard to Simplify Trace Contaminant Analysis in Brine

Thermo Fisher Scientific, Air Quality Instruments  - April 1, 2009
Thermo Fisher Scientific Moves Science Forward at ACHEMA 2009

PANalytical, Inc.  - June 9, 2008
PANalytical Launches SuperQ Thin Film and Solar Cell Analysis Solutions at SEMICON West 2008

PANalytical, Inc.  - May 21, 2008
The Complete Calibration Solution for XRF Analysis of Petrochemicals

PANalytical, Inc.  - February 21, 2008
PANalytical at PITTCON 2008

RAE Systems  - September 11, 2007
RAE Systems Wins Radiation Detector Order from South Carolina

IXXAT Automation GmbH  - February 8, 2007
FlexRay Rest Bus Simulation with FlexRay CCM and MultibusAnalyser


More Products in the News...


Category Advertisements




ThomasNet News Advertisers




Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy