 Incremental Encoders provide up to 10,000 ppr.SICK STEGMANN, INC.
Dayton, OH 45413
Jun 08, 2006
Available with IP65-rated housing, Model DGS66 incremental encoders are offered in blind and through hollow shaft configurations for 6, 8, 10, 12, and 14 mm, or 3/8 and ½ in. shafts. With either TTL or HTL electrical interfaces, encoders suit applications in machine tool, textile, woodworking, and packaging.
|
 Monitor displays dew-point, wet-bulb, humidity, and temperature.Control Company
Friendswood, TX 77546
Jun 08, 2006
Displaying current, minimum, and maximum levels, Traceable® Monitor activates settable high/low alarm for all 4 readings. With range of 1-99% RH and resolution of 0.1%, unit offers accuracy of ±4% between 20-80% RH. Temperature range is -40 to 70°C with resolution of 0.1° below 100 and accuracy of ±1°C. Measuring 4 1/8 x 4 1/8 x 1 in. and weighing 4¼ oz, monitor is supplied in high impact, chemical-resistant ABS plastic case.
|
 Flow Meter measures process and plant fuel gases.Fluid Components Intl.
San Marcos, CA 92069 5115
Jun 08, 2006
Designed for direct in-line installation, Model ST75 direct mass flow instrument services line sizes from 0.25-2.0 in. and flow ranges from 0.008-839 scfm. Suited for low- and high-flow applications, unit offers up to 100:1 turndown ratio, accuracy of ±2% of reading, and ±0.5% repeatability. Meter features wireless IR technology that allows user to remotely monitor measurements, make setting changes, and read trouble-shooting codes.
|
 Melting Point Apparatus accommodates up to 3 samples.SciLabware (formerly Barloworld Scientific)
Staffordshire ST15 0SA United Kingdom
Jun 08, 2006
Designed for measuring melting points, Model SMP3 features max temperature of 360°C, programmable heating rates, and automatic cooling. Heating block incorporates platinum resistance sensor for responsive temperature control. Membrane keypad allows setting of desired start temperature and heating ramp rates, which are fully adjustable from 0.5-10°C/min in 0.1°C increments. Backlit alphanumeric LCD display indicates temperature and stage of operation.
|
Data Acquisition Devices support all standard thermocouples.Omega Engineering, Inc.
Stamford, CT 06907
Jun 08, 2006
Offered in 8-, 16-, and 32-channel models, Series OMET-USB-73T features 24 digital inputs and outputs, which let user control external contacts and relays in case of alarm or other event requiring action. Units offer USB 2.0 compatibility, ±2°C accuracy, and max sampling of 200 readings/sec. They are suited for environmental applications such as monitoring of furnaces, cold storage, and computer rooms.
|
Dual Multiplexer-Buffers optimize signal integrity.National Semiconductor Corp.
Santa Clara, CA 95051-0695
Jun 08, 2006
With 18 picoseconds of jitter performance, Models DS15MB200, SCAN15MB200, and DS08MB200 extend reach of LVDS signals across cables and backplanes in point-to-point applications. Dual mux-buffer configuration manages redundant differential data streams at speeds up to 1.5 Gbps. Each half of device provides 1:2 buffer and 2:1 multiplexer for duplicating one signal into 2 output streams or selecting from 2 alternate input data sources. Each unit is housed in 48-pin LLP® package.
|
 Ground Monitoring System senses high resistance in soil.Rabun Labs, Inc.
Mason, TX 76856
Jun 07, 2006
Solid-state GMMS Ground Monitoring System continuously monitors integrity of electrical grounding system. When it senses moisture in soil has reached unacceptable level, it automatically activates solenoid valve, allowing water or resistance lowering material to be applied to area. Once soil resistivity reaches acceptable level, unit automatically resets and resumes monitoring. Unit also monitors connection of AC outlets and equipment to electrical grounding system.
|
 Insulation Testers have flexible silicone test leads.Hoyt Electrical Instrument Works, Inc.
Penacook, NH 03303 8798
Jun 07, 2006
Designed to read measurements in harsh environments, SEW 4103 IN and 4104 IN meters have built-in and integral guard circuitry to eliminate measurement errors introduced by surface leakage current. They are controlled by CMOS microprocessor and feature digital calibration, auto-off function, and smart auto ranging (5 current ranges x 4 voltage range). Along with visual and acoustic indication of voltage, products feature color-coded leads and sockets.
|
 Low Differential Pressure Transducer offers 1% FS accuracy.Setra Systems, Inc.
Boxborough, MA 01719
Jun 06, 2006
Suited for automated weather systems, Model 260 features user-selectable pressure ranges and analog outputs, standard LCD, and AC/DC excitation on voltage output operation. With configure-on-the-fly ability, unit offers pressure ranges from 0.1-10 in. WC full scale, and may be field-configured as unidirectional or bi-directional. External push button for field zeroing provides fast, accurate zero, without compromising full-scale performance.
|
Reference Design enables high-definition set-top boxes.STMicroelectronics
Lexington, MA 02421
Jun 06, 2006
Utilizing Windows CE 5.0 Networked Media Device Feature Pack, STB Reference Design accelerates development cycle of set-top boxes, HD-DVD players, and digital video recorders. It integrates STB7109 high-definition decoder, USB 2.0 host port, SATA port and Ethernet interface, which enables STB to be central part of home network. Digital copy-protected HDMI allows digital connection to any HD-ready flat panel display.
|
Universal Testing Machines come in table and floor models.ADMET
Norwood, MA 02062
Jun 06, 2006
Offered in tabletop configurations from 2,250-10,000 lbf and floor-standing models from 10,000-30,000 lbf, dual-column electromechanical eXpert 26xx Series provides compression, tension, and flexure testing of biomaterial, elastomer, film, foil, metal, packaging, plastics textile, and wire components. Units features fast-acting servo motor and twin ball-screws for axial alignment, stiffness, and crosshead guidance. Three different controllers are available.
|
Reference Torque Transducer provides 0.05% accuracy.HBM, Inc.
Marlborough, MA 01752 3014
Jun 06, 2006
Utilizing principle of axial shear, Model TB2 is designed for non-rotating use in static and dynamic measurements. It is available in 6 nominal measuring ranges of 500 Nm, 1 kNm, 2 kNm, 3 kNm, 5kNm, and 10 kNm. Standard system is quasi-hermetically sealed and can optionally be provided protected to IP67 as defined by EN 60529. Relative standard deviation of repeatability is less than ±0.01%, and linearity deviation including hysteresis is less than ±0.03%.
|
 Distance Measuring Instrument is effective up to 18 ft.SensComp, Inc.
Livonia, MI 48150
Jun 05, 2006
As matched component pair, Series 9000 Ultrasonic Ranging Module and Piezoelectric Transducer provide distance measurement and proximity detection from 1-18 ft. Piezoelectric sensor emits only minimally audible clicking sound. Also available, Series 9000 OEM Kit offers 2 Series 9000 Transducers, 2 supporting Ranging Modules, as well as theory and operation booklets, making it suited for prototype and feasibility studies or for classroom use.
|
 UT Data Acquisition System targets power generation market.Zetec, Inc.
Issaquah, WA 98027 0140
Jun 02, 2006
Featuring up to 64 simultaneously active phased array channels, Z-Scan PA allows for real-time data compression, signal averaging, high pulsing rate, and Dynamic Depth Focusing. It is driven by UltraVision® software from desktop or notebook PC through 100BaseT Ethernet link. By supporting 64 channels for acoustic beam forming, unit allows for design of UT inspection solutions in complex geometries where simultaneous variation of refracted and skew angle are required.
|
 Cable Tester produces pass/fail reading within seconds.Ideal Industries, Inc.
Sycamore, IL 60178
Jun 02, 2006
Used to verify that installed cabling will support voice, video, and data applications, SIGNALTEK offers Gigabit performance testing by transmitting 10/100/1000 Mbps Ethernet packets and measuring errors on link in accordance with IEEE 802.3ab Gigabit Ethernet standard. Handheld device also supports Bit Error Rate Testing (BERT) and integrates time domain reflectometer. Along with monitoring mode, unit features intelligent autotest function and 32 MB internal memory for data storage.
|
Portable Network Analyzer offers remote operation.GL Communications Inc.
Gaithersburg, MD 20877
Jun 02, 2006
Compatible with any notebook PC, USB-based T1 E1 Analyzer performs analysis and emulation of various signal types such as voice, digits, and tones as well as analysis of protocols including HDLC, ISDN, SS7, CAS, Frame Relay, GSM, GPRS, CDMA, and UMTS. User can capture and transmit entire raw T1 or E1 signal simultaneously on 2 full duplex ports, and analyze echo and voice quality on voiceband channels. With remoting or scripting software, user can control and monitor remotely.
|
Navigation Device offers Bluetooth wireless connectivity.Garmin International, Inc.
Olathe, KS 66062
Jun 02, 2006
StreetPilot 2820 makes it possible for automotive and motorcycle consumers to utilize hands-free calling with full user interface. Numbers can be retrieved and dialed using phone's contact list or from phone's call history log. Calls can also be made from point-of-interest database that includes hotels, restaurants, and stores. For longer trips, waterproof device includes MP3 player and audiobook player. Optional real-time traffic is available.
|
 Wet/Wet DP Sensor comes in hydrogen-compatible package.American Sensor Technologies, Inc.
Mt. Olive, NJ 07828
Jun 01, 2006
Featuring AST's Krystal Bond(TM) Technology, Model 5000 safely measures differential pressure (DP) of hydrogen and other gases. It does not contain internal O-rings or fluid-filled cavities, and diaphragm is constructed of 316L stainless steel wetted materials. Offered in bi-directional and uni-directional pressure ranges for applications with line pressures up to 1,000 psi, design provides over-range and burst protection to 5x rated line pressure or 2,000 psi.
|
Signal Conditioner accepts 3 channels of transducer types.VIP Sensors
San Juan Capistrano, CA 92675
Jun 01, 2006
Accepting piezoelectric, piezoelectric with integral electronics (IEPE), or voltage transducer types, Model 5005 vibration signal conditioner has double integration stage that allows output voltage to be proportional to acceleration, velocity, or displacement. Input signals are processed through low-noise amplifiers with programmable gains for different sensitivities and full scale settings. Device is capable of reading IEEE 1451.4 compliant TEDS provided with IEPE transducers.
|
Signal Source Analyzer uses clock jitter analysis software.Agilent Technologies, Inc.
Santa Clara, CA 95051
Jun 01, 2006
Used in combination with Signal Source Analyzer, SSA-J Software provides data-independent clock-jitter evaluation with femto-second resolution in digital communication systems and for high-speed clock device design in semiconductor industry. Real-time jitter spectrum analysis from 1 Hz to 40 MHz offers designers accurate evaluation on random jitter and periodic jitter within user-definable observation bandwidth in seconds.
|
(Showing headlines 9861 - 9880) << 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754
|
|
|