Test & Measuring Instruments
(Showing headlines 9841 - 9860) << 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 ...
|
 Materials Tester Upgrade System features smart indicator.Electro Standards Laboratories
Cranston, RI 02921 3403
Jun 15, 2006
Providing electronics to older tensile testing test frames, Material Tester Upgrade System includes Model 4215 Smart Indicator, load cell and extensometer, and Excel-compatible dataView software, which provides test statistics, data acquisition, setup, calibration, and color plotting. Smart Indicator combines force channels, encoder position channels, print capabilities, and RS232/485 serial communications while offering ±999,999 bipolar range display and 24-bit resolution.
|
Evaluation Platform supports VRS51L2070 Versa 8051 MCU.Ramtron International Corp.
Colorado Springs, CO 80921
Jun 15, 2006
VersaKit-20xx evaluation platform facilitates system prototyping and design development with VRS51L2070 system-on-chip. Kit features development board to support microcontroller, Versa-JTAG programming/debugging interface, DB25 Parallel Cable, and power supply. Development board incorporates set of probe vias and header footprints for access to chip peripherals and I/Os, RS-232 transceiver and 2 DB9 connectors for UART access, and 2 tact switches for manual reset/interrupt triggering.
|
Hydrogen Sensors perform in harsh environments.H2scan Corp.
Valencia, CA 91355
Jun 15, 2006
Providing real-time measurements in extreme conditions, HY-OPTIMA handheld model 500 and HY-ALERTA in-line model 700 include membrane and coating over sensor die that allows hydrogen to penetrate but prevents penetration of moisture, CO, Sulfur, and other gases. Sensing element of both models utilizes palladium nickel capacitor and palladium nickel resistor for threshold measurements from 15-5,000 ppm. In-line model can operate in process streams up to 125°C.
|
Audio Analyzer has 8 simultaneous channels of analog I/O.Audio Precision, Inc.
Beaverton, OR 97075
Jun 15, 2006
Able to take multiple measurements simultaneously, PC-controlled APx585 employs user-interface that let users automate test sequences without any programming. Test sequences are supported with integrated reporting facility and reports are exportable. To facilitate design team collaboration, project file structure includes all measurement settings and automated sequences. Along with real-time input signal monitors and general-purpose FFT analyzer, product uses continuous sweep method.
|
In-Line Flowmeter uses transit-time ultrasonic technology.Omega Engineering, Inc.
Stamford, CT 06907
Jun 15, 2006
Suited for consumable or industrial water applications, FDT100 Series employs 2 flow sensors that alternately transmit and receive signal. Time of flight is used to measure flow rate from 65-1,100 gpm (nominal), depending on flange size. With no moving parts, battery-powered meter exhibits minimal pressure loss and does not require filtration. Product comes with integrally mounted display or remote-mount version and 150 lb, 2-8 in. ANSI flanges.
|
 DeviceNet Tachometer converts pulse frequency to rpm units.Electro-Sensors, Inc.
Minnetonka, MN 55343 9108
Jun 14, 2006
Suited for real-time maintenance feedback and machine diagnostics, network-powered SpeedTalker DN (UI) is capable of measuring speed and direction when using bidirectional sensor. Product provides measured shaft RPM from up to 2 input channels along with status of up to 8 independent under/over speed threshold alarms over DeviceNet network. Along with electrically isolated universal differential pulse inputs, tachometer provides isolated 24 Vdc sensor power.
|
 Signal Conditioner Board offers auto sensor identification.Electro Standards Laboratories
Cranston, RI 02921 3403
Jun 14, 2006
Embedded, digital Model 4327 CellMite(TM) connects directly to strain gage transducer and simultaneously generates serial output for connection to PC and ±10 V analog output for interface to DAQ systems. It has onboard storage for 3 calibrated sensors, each with integrated 6-point calibration and independent user-specified display setup parameters. Along with automatic TEDS-Tag(TM) sensor identification, unit features 16-character auto identifying display that provides direct readout viewing.
|
 Force Transducer measures tensile and compressive forces.HBM, Inc.
Marlborough, MA 01752 3014
Jun 14, 2006
While used for static and dynamic component tests in test benches and test equipment, U10M specifically suits testing applications including double bridge, mechanical adapters, connector variants, or TEDS. Integrated compensating circuit reduces crosstalk between bending moments and lateral forces; bending moments are determined for each transducer individually. Rotationally symmetrical product comes in 9 ranges with nominal values from 1.25-500 kN.
|
Automated Interface streamlines direct mail operations.Pitney Bowes
Stamford, CT 06902
Jun 14, 2006
Flexible Bindery Interface helps boost productivity for direct mail lettershops and service bureaus by integrating existing stand-alone bindery process with Pitney Bowes high-speed inserters. It streamlines transfer of printed and folded materials through service bureau's unwinders, cutters, and folders. Folded materials are scanned to help ensure integrity as they exit feeder and can be processed on deck at speeds up to 14,000 mail pieces/hr.
|
Prototype System tests injection molded parts.J & L Plastic Molding
Wallingford, CT 06492
Jun 14, 2006
Based on automating and standardizing moldmaking and molding process, Prototype Plus provides design engineers and product developers with way to test new injection molded parts, then seamlessly transition into production. Accommodating both up-and-down and side-action part design, system can produce parts that run on injection molding machines from 28-200 tons, with shot size from 0.5-22 oz. EDM technology may be utilized for intricate shapes and desired finishes.
|
Time-to-Digital Converter Chip offers 10 ps resolution.Transducers Direct
Miamiville, OH 45147
Jun 14, 2006
With measurement range up to 40 µsec, Model TDC-GPX allows distance measuring accuracy of ±1 mm rms to range of 1,500 m for laser range finders, radar, medical imaging scanners, ultrasonic flow meters, and navigation systems. Four selectable modes include 81 psec resolution with 0 to endless measurement range, and 10 psec resolution with 100 nsec to 10 µsec range. Power consumption from 39-45 mA makes unit suited for battery-powered devices.
|
Media Streamer uses antenna for extended distances.Avocent Corp.
Huntsville, AL 35805
Jun 14, 2006
Deployed in point-to-point or point-to-multipoint configuration, EWMS1000 Wireless Media Streamer delivers full motion streaming video and audio to multiple display devices. Emerge UNI-8dB directional antenna focuses energy of signal into intensified unidirectional beam. In line-of-sight applications, antenna allows receiver to be placed up to 1,000 ft from transmitter. Transmitter and receiver antennas work in 802.11a band and provide frequency range of 5.150-5.825 GHz.
|
 Inspection System detects wafer edge defects.Bede
Durham DH1 1TW United Kingdom
Jun 13, 2006
Sensitive to dislocations, precipitates, mechanically introduced cracks, and inclusions, BedeScan(TM) defect inspection system is capable of looking at process induced defects on surface of wafer and detects crystallographic abnormalities inside wafer that can lead to wafer breakage. System monitors pin marks, thermal slip dislocations, misfit dislocations, back-side and front-side scratches, as well as surface and buried mechanical edge damage.
|
 Burn-In System offers memory and logic testing capabilities.Micro Control Co.
Minneapolis, MN 55432
Jun 13, 2006
LM-1 Logic and Memory Burn-In System has system capacity of 1,536 devices when individual temperature control is required or 6,400 device capacity when conventional burn-in cycle is run. Burn-in-with-test system features 300 A current per burn-in board, programmable temperature control up to 150şC, and scan mode vector memory up to 1 G deep. Handling up to 32 burn-in boards, system can be customized to burn-in different device types during same cycle.
|
 Test System supports IEEE 802.16 based WiMAX products.LitePoint Corporation
Sunnyvale, CA 94085
Jun 13, 2006
Based on integrated vector signal analyzer and vector signal generator architecture,
IQmax(TM) system tests devices based on WirelessMAN OFDM PHY standards, including all bandwidth and data rate options. Dual RF ports are selectable for Tx or Rx operation and support 3.3-3.8 GHz frequency band. IQsignal Analysis Suite provides instrument set-up, control, and analysis functions including RF and I&Q graphs, frequency spectrogram, power spectral density, and constellation diagrams.
|
 Service Tool visualizes entire BACnet® system.TAC
Carrollton, TX 75006
Jun 13, 2006
Weighing less than 1 lb, portable Roam IO2 provides wireless field access to controller point information. Compact hardware adapter offers mobility through local connection to field bus or Ethernet network or wireless connection with Bluetooth® adapter. It automatically discovers and edits BACnet devices from third parties as well as TAC Andover Continuum(TM) BACnet and Infinet(TM) controllers on network, providing multiple displays of entire BACnet system.
|
 Signal Conditioner IC delivers diagnostics to sensors.ZMD
Dresden Germany
Jun 13, 2006
Suited for use with piezo-resistive bridge sensors, ZMD31015 programmable signal conditioner IC provides real-time diagnostics to detect any faulty connections, shorts, and power loss events. Measured and corrected bridge values are provided at signal pin which can be configured as analog voltage output or as 1-wire serial digital output which can also be used for PC-controlled procedure to program calibration coefficients into on-chip EEPROM.
|
 Gauges suit mediums not corrosive to brass or bronze.Bee Valve Inc.
Elyria, OH 44035
Jun 13, 2006
Model 20 dry-filled pressure gauges feature dual scale that offers both psi and bar measurements. Housed in black-painted steel case, bottom mounting gauges are available in 1.5, 2, and 2.5 in. sizes. Pressure ranges available include 0-30 psi vacuum, and 0-30, 0-60, 0-100, 0-150, and 0-300 psi.
|
 Gas Analyzers feature dual ADC architecture. Midac Corp.
Irvine, CA 92614 6016
Jun 13, 2006
Combining FTIR spectrometer system, gas cells, sample manifold, valve control electronics, and software, Titan-OL Systems provide real-time, multi-point, multi-component quantitative gas analysis. Fiber optic distribution electronics provide single hub for temperature, pressure, mass flow, external alarm, and optical switching signals and can accommodate up to four 12-port manifolds for total of 48 sample, purge, and calibration lines. Gas cells are available in path lengths from 1 cm to 30 m.
|
PCI Boards offer 16-bit/1 MHz multifunction synchronous I/O.Omega Engineering, Inc.
Stamford, CT 06907
Jun 13, 2006
Along with 16-bit/1 MHz ADC, 2 timer outputs, and four 32-bit counters, OMB-DAQBOARD-3000 Series features 16 analog input channels, user-expandable to 64; up to four 16-bit/1 MHz analog outputs; and 24 digital I/O. Boards are compatible with optional OMB-PDQ30 expansion module, which allows system to accept up to 24 thermocouple inputs. DaqView software enables setup, data logging, and real-time data viewing without any programming skills.
|
(Showing headlines 9841 - 9860) << 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755
|
|
|