Test & Measuring Instruments
(Showing headlines 9681 - 9700) << 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 ...
|
 Inline Checkweigh-Cuber offers multifunctional operation.Cornerstone Automation Systems, Inc.
Prosper, TX 75078
Aug 02, 2006
Offered as single freestanding system, CASI-4971 is designed for distribution center use in random check weigh and freight manifesting applications. PC-based, self-contained, in-motion checkweigher is designed with 4 compression load cells mounted on 3 in. steel frame. It utilizes CASI 1100 Industrial PC scale controller and features configurable conveyor control; secure, 3-level login system; and ability to connect to RF Tag Readers and barcode scanners.
|
Spot Radiometer measures full range of NVIS radiance.Gamma Scientific
San Diego, CA 92123 1876
Aug 02, 2006
NVG-4040 performs NVIS-A, NVIS-B, and NVIS-C radiance measurements and is optimized for full range of photopic measurements. Device features 50 mm macro lens, user adjustable apertures of 5, 2, 1, 0.5, 0.33, and 0.1°, NVIS-compatible touch screen, threshold-detection alarm, and automated USB interface. Conforming to MIL-L-85762A and MIL-STD-3009, unit is designed for measuring displays and instrument panels used with night-vision goggles.
|
System tests, measures, and monitors VoIP deployment.JDSU
San Jose, CA 95131
Aug 02, 2006
Through intelligent data collection, consolidation, and correlation, NetComplete Service Assurance Solution provides cable operators with turn-up verification, rapid problem detection, segmentation, and troubleshooting. It measures hybrid fiber coaxial characteristics, cable modem termination system, and IP network, providing visibility into problem areas affecting voice signal clarity. System can also perform real-time analysis of mean opinion score and of simultaneous customer calls.
|
Spectrum Analyzer includes PDA and desktop software.Datastick Systems Inc.
Santa Clara, CA 95050
Aug 02, 2006
Vibration Spectrum Analyzer, Model VSA-1212, uses software for predictive, conditions-based maintenance and troubleshooting. Datastick Spectrum v1.5 for PDA provides vibration severity alert-level system with color display of alerts based on overall vibration levels, as well as linear averaging and peak-hold capabilities. Companion desktop PC software, Datastick Reporting System v1.5 for VSA, automatically builds machine histories in Microsoft® Excel® with data imported from Datastick Spectrum.
|
 Digital I/O Module doesn't require external power supply.Advantech Automation Corp.
Cincinnati, OH 45240
Aug 01, 2006
USB-4761 16-channel digital I/O module features 8 form C output relays allowing configuration as NO, NC, or SPDT, with 3 A per channel capacity at 24 Vdc or 250 Vac. Accepting independent wet input from 10-30 Vdc, sinking or sourcing, 8 optically isolated input channels are protected to 2,500 Vdc. Windows software includes configuration utility offering full manual control and development libraries.
|
 Web Empowered Data Logger offers remote monitoring solution.Logic Beach, Inc.
La Mesa, CA 91942
Aug 01, 2006
Self-contained, portable IntelliLogger(TM) models IL-20 and IL-80 provide network-enabled methods of data collection and retrieval for remote, browser-based monitoring. Instrument utilizes HyperWare-II(TM) icon-based, drop-and-drag programming environment and has built-in Ethernet and Web serving capabilities. Automated, wide-spread dissemination of collected data is accomplished via features that allow for Web presented data and control, data FTP actions, and e-mail of alarms and data.
|
 Temperature Sensing Solution has DIN Form B-compliant case.Precision Linear Systems, Inc.
Cupertino, CA 95014
Aug 01, 2006
Model DF01 is comprised of solid-state temperature sensor and 4-20 mA loop-powered transmitter manufactured on same flexible circuit substrate and connected together by traces on flex. Sensor and transmitter are calibrated and set over their full operating temperature ranges at test, -50 to +150°C and -25 to +75°C respectively, which lends to model-dependent system accuracies of ±0.3, 0.5, or 0.8°C. Sensor is ready to be inserted and sealed into sensor tube.
|
 Single Gas Monitor is offered with Hydrogen Cyanide sensor option.Industrial Scientific Corp.
Oakdale, PA 15071 1500
Aug 01, 2006
Operated via 4-button interface, dockable GasBadge® Pro with HCN sensor option is suited for use in precious mining, gold plating, food and beverage, and hazardous materials industries. It can be adapted with interchangeable smart sensors to monitor unsafe levels of oxygen or any one of 9 other toxic gases. Audible, vibrating, and visual alarms indicate when set ranges are exceeded, and backlit LCD displays gas and concentration level. Product logs up to one year of survey data.
|
 I/O Modules suit DeviceNet and Profibus-DP applications.Lumberg, Inc.
Midlothian, VA 23113
Aug 01, 2006
LioN Series, comprised of LioN-S and LioN-M housing styles, can be used in any combination of inputs and outputs without any configuration. LioN-S has Pico (M8) I/O and Micro (M12) power and bus connectors and is offered in 8-channel versions, while LioN-M has Micro (M12) and Mini (7/8 in.) power connectors. Both offer short circuit diagnostics, optimized spacing between ports, diagnostic LED, and un-potted design for shock and vibration resistance.
|
 Clamp Meter is CAT III 600 V rated.Fluke Corp.
Everett, WA 98203
Aug 01, 2006
Designed to measure ac voltage and current, Fluke 902 HVAC Meter also incorporates 80BK DMM temperature probe. Meter clamps to 750 MCM dia wire and has integrated low pass filter to detect voltage output of variable frequency drives. Allowing technicians to troubleshoot and repair heating, ventilation and air conditioning systems, meter can be used to capture flue gas temperature, conduct flame rod testing, and measure start and run motor capacitors.
|
Voltage Monitor features 4 different measurement inputs.Linear Technology Corp.
Milpitas, CA 95035
Aug 01, 2006
LTC2914 voltage monitor IC contains undervoltage (UV) and overvoltage (OV) inputs and allows specific UV and OV trip threshold configuration with ±1.5% accuracy of monitored voltages. Buffered reference output and 3-state input polarity-select pin allow monitoring of 2 separate negative voltages. Featuring input glitch filters that eliminate noise and 70 µA quiescent current, IC is suited for telecom/network equipment, storage servers, and desktop and notebook computers.
|
 Drum and Barrel Scale features separate digital indicator.Alliance Scale Inc.
Canton, MA 02021
Aug 01, 2006
Available in 500 and 1,000 lb. capacity models, Alliance/Cardinal Portable Drum and Barrel Scale has built-in wheels and handles for portability. Measuring 30 x 40 x 4.5 in., unit is made of heavy-duty steel with baked-on powder finish and includes 2 live rails for weighing skids and crates. Battery-powered digital weight indicator with 5-digit, 1 in. high LCD display can be mounted anywhere, and offers selectable unit conversion and RS-232 output.
|
 Linear Position Encoders provide direct load measurement.Balluff, Inc.
Florence, KY 41042-0937
Aug 01, 2006
Featuring sensing head that floats above precision-encoded magnetic band, Series BML monitors linear load position, independent of actuator drive employed, eliminating incorrect position information due to backlash. Configuration delivers up to 24 m of non-contact, wear-free position tracking at up to 10 m/s with no signal degradation. Model S1A offers max resolution of 1 µm and system accuracy of ±10 µm, while Model S1B provides 5 µm resolution and ±50 µm accuracy.
|
 Pressure Transducers tolerate spikes without damage.Measurement Specialties, Inc.
Hampton, VA 23666
Aug 01, 2006
Schaevitz® Bonded Foil Strain Gages are available in 0-75 to 10,000 psi and temperature range of -65 to 250ºF, compensated to -4 to 185ºF. Pressure transducers feature Over Travel Stop for diaphragm, which enables sensor to handle at least 5x full scale over-range pressure spikes without damage or drift. Design affords thermal isolation to high temp transients, shock loads, and vibration, allowing use in military, aerospace, and industrial applications.
|
Optic Fiber Thermometers target semiconductor processes.Advanced Energy Industries Inc.
Fort Collins, CO 80525
Aug 01, 2006
Designed for RTP, HDP-CVD, epi, ALD, and HDD applications, Model OR4000T provides multi-channel temperature measurement and enables integrated measurements within multiple chambers. Model OR4000E offers same performance with added real-time emissivity compensated temperature measurement and ability to support growth rate monitoring. Single-channel Model OR400T provides non-contact, in-situ temperature measurement and immunity from RF noise.
|
DSCs and MCUs have security features for protecting IP.Microchip Technology, Inc.
Chandler, AZ 85224 6199
Aug 01, 2006
Supplied as 16-bit devices, dsPIC® digital signal controllers (DSCs) and PIC24H microcontrollers (MCUs) allow multiple parties in collaborative system design to share memory, interrupts, and peripherals of single chip without compromising their intellectual property (IP). CodeGuard(TM) security lets OEMs divide and share 3 segments of on-chip memory with tiered levels of access. Features also enable secure field upgrades of product firmware.
|
 Inspection System monitors pipes and sewer systems.ECA HYTEC
Cedex 5 BP 4403 France
Jul 31, 2006
Able to inspect 6-47 in. dia pipes, PIPE CRUISER 150 trolley incorporates 200 W carrier, 6 multidirectional drive wheels, rotating zoom camera, and rear-mounted backwards-facing camera. Cable tension management system is equipped with .3 in. dia cable. Compatible with Pipe Cruiser 150 system, Mini Pipe Cruiser 100 inspects secondary pipes with 3-16 in. dia, and is available with axial or rotating head camera allowing entry into 10 in. dia branching junction chambers.
|
 Sensor and Transmitter target HVAC applications.Precision Linear Systems, Inc.
Cupertino, CA 95014
Jul 31, 2006
Combining solid-state temperature sensor and 4-20 mA transmitter, Model MF01 provides system accuracy of ±0.5 and 1°F. Sensor is ready to be inserted and sealed into sensor tube. Injection molded miniature case holds transmitter and output terminals and can be mounted in standard HVAC wall mount or duct probes. Both sensor and transmitter are calibrated and set over their full operating temperature ranges at test.
|
 Portable Oscilloscope features 8 onscreen traces.AEMC Instruments
Foxborough, MA 02035
Jul 31, 2006
Model OX 7104-CK Oscilloscope incorporates FFT analyzer, TRMS multimeter, harmonic analyzer, 4-channel digital recorder with sample rate to 800 µs, and 8,000-count display. Automatic measurement window displays 18 parameters, including ac and dc voltage, current, resistance, and temperature measurements. Suited for laboratory or field use, device uses Probix plug and play accessories and can be remotely managed via Ethernet link. Instrument is battery or line voltage operated.
|
Test System targets wireless communication market.Agilent Technologies, Inc.
Santa Clara, CA 95051
Jul 31, 2006
Comprised of mobile station tester, test software, and RF shield box with built-in antenna coupler, Model GS-8210 enables users to perform functional testing of mobile phones on manufacturing line, fault diagnosis and adjustments on manufacturing QA and repair lines, and go/no-go test at service shops. RF shield box offers environment to simulate call operation, provide test results, and avoid conflicts with real networks, while software automates user's testing program.
|
(Showing headlines 9681 - 9700) << 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755
|
|
|