Test & Measuring Instruments
(Showing headlines 9301 - 9320) << 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 ...
|
CDMA2000 Test Systems combine simulation and monitoring.Sunrise Telecom Inc.
San Jose, CA 95119
Nov 24, 2006
Integrating with 3GMaster® analyzer, Models IS-41 and IOS A1 provide control of message building with graphical customization of message content and signaling flow, supported by message and script library. Model IS-41 is suited for testing IS-41 nodes on different nodes such as HLR, MSC, VLR, Message Center, and Mobile Positioning Center as SS7 nodes. Model IOS A1 CDMA2000 tests signaling and interoperability between simulated Base Station System and real Mobile Service Switching Center.
|
Condition-Monitoring Device provides bearing testing.Timken Co., The
Canton, OH 44706 0932
Nov 24, 2006
Utilizing shock-pulse analysis, hand-held, portable Bearing Tester checks condition and lubrication of ball- and roller-type bearings. Built-in microprocessor analyzes shock-pulse patterns from bearing and displays immediate evaluation on green-yellow-red condition scale. Infrared sensor measures surface temperature, while stethoscope function detects sound irregularities via headphones.
|
Oscilloscopes are optimized for test-system use.Agilent Technologies, Inc.
Santa Clara, CA 95051
Nov 24, 2006
LXI class C-compliant Agilent 6000L Series, comprised of 3 digital storage oscilloscopes (DSOs), offers 4 channels of measurements in rack-mountable, 1U-high form factor. Along with remote capabilities and graphical Web interface, products feature 100 MHz, 500 MHz, or 1 GHz analog bandwidth and up to 4 GSa/sec sample rate. Each comes with 8 Mpts MegaZoom III deep memory; LAN, GPIB, and USB interfaces; and optional secure environment mode.
|
Recorder targets high-end communications.ASC telecom AG
Hoesbach 63768 Germany
Nov 24, 2006
Able to record up to 480 phone lines simultaneously, Linux-based MARATHON EVOLUTION XXL suits companies with numerous telephone, VoIP, or security-related communications. It also offers hybrid recording for mixed VoIP and TDM environments. Housed in rack-mountable, 19 in. chassis, device may be used independently or in networked system for multiple departments or locations. Users may preserve up to 280,000 hr of recordings online and on 2 additional storage systems.
|
Test and Repair System is suitable for nanometer memories.ARM Ltd.,
Sunnyvale, CA 94085
Nov 24, 2006
Enhancing manufacturing test quality for 45, 65, and 90 Nm memories, emBISTRx(TM) system features Advantage(TM) and Metro(TM) memory compilers, and embedded BIST/BISR controller. Minimizing area impact on memory sub-system through optimal partitioning of test and repair logic, system also reduces routing congestion and number of interconnects to enable faster testing. System has algorithms to detect memory faults such as excessive leakage, weak bits, and resistive shorts and opens.
|
 Multigas Detector offers variety of advanced features.MSA
Pittsburgh, PA 15230 0426
Nov 22, 2006
ORION®plus Detector combines features of ORION® Multigas Detector with range of infrared and toxic sensor options. Infrared sensor delivers stable readings in environments with challenging temperature and humidity effects. Providing one-hand operation, detector offers standard datalogging, internal pump, and rechargeable NiMH or disposable alkaline battery packs.
|
Meter Reading System offers wireless communication.E-Mon Corp.
Langhorne, PA 19047
Nov 22, 2006
Wireless Automatic Meter Reading System consists of mesh communication network that allows single-phase, multi-tenant managers to monitor and bill for actual energy usage. D-Mon Class 4100 Meters are equipped with self-configuring, peer-to-peer, multi-hopping wireless transceivers that route energy data between meters and central data storage unit. Wireless Gateway stores interval energy data until downloaded via Ethernet or Internet using wireless meter reading software.
|
 Portable Calibrator delivers precise concentrations of gas.VICI Metronics, Inc.
Santa Clara, CA 95051
Nov 21, 2006
Offered with choice of plumbing and flow configurations, Dynacalibrator® Model 150 generates precise ppm or ppb concentrations of chemical compounds in gas stream using permeation devices as trace gas source. Passivated glass-coated permeation chamber houses permeation device, with measured inert carrier gas sweeping calibration gas/vapor from chamber. Digital controller maintains chamber temperature at set point with accuracy of ±0.01°C, traceable to NIST standards.
|
 Flow Indicators suit analog signal applications.Dwyer Instruments, Inc.
Michigan City, IN 46361
Nov 21, 2006
Accepting all standard process signals such as 4-20 mA, 1-5 V, and 0-5 V, Series FIV flow rate/totalizer/batch controllers feature 7-segement LED display that provides 4½ digits of flow rate and 6 digits of total. For applications requiring more than display of rate or total, meters can be equipped with 2 relays and 4-20 mA retransmission output. Relays can also be used for alarming based on flow rate or for batch controlling based on flow total.
|
Interposer Solution connects SATA drives to SAS systems.SiliconStor, Inc.
Fremont, CA 94538-6532
Nov 21, 2006
Based on AAMUX technology, SS1320 Active-Active Multiplexer chip enables storage vendors to build SATA Interposer board that interconnects SATA drives with enterprise-class features to SAS and Fibre Channel-to-SATA storage systems. It minimizes SATA spin-up delays with optimized drive detection times and offers in-band diagnostic controls for PHY error counter and asynchronous host notification. Other capabilities include drive spin-up and error recovery control and resource fencing.
|
Chart Recorder monitors chlorine residuals in water.Analytical Technology, Inc.
Oaks, PA 19426
Nov 21, 2006
Combining direct measuring polarographic sensor and circular chart recorder, Model B20 provides 24-hr or 7-day recording of chlorine residuals in measuring ranges adjustable from 0-5 or 0-20 ppm. Sensor utilizes polymeric membrane to isolate sensing electrodes from sample and eliminate potential for electrode contamination. Clear, constant-head flowcell assembly maintains desired flow. Model B20 is housed in NEMA 3 enclosure with circular glass viewing window.
|
Functional Test System streamlines testing wireless handsets.Agilent Technologies, Inc.
Santa Clara, CA 95051
Nov 21, 2006
With multi-format test capabilities, GS-8000 Lite Wireless Functional Test System supports various UMTS wireless communication standards such as GSM, GPRS, EGPRS, and W-CDMA. Automated test is enabled through GS-8000 Lite's software which features 1-button auto-tests and library of pre-defined tests. Unit uses N9360A Multi-UE tester with 2 semi-automated RF shield enclosures, maximizing system utilization by reducing handling time.
|
 DAQ Module and Chassis handle multiple I/O operations.Agilent Technologies, Inc.
Santa Clara, CA 95051
Nov 20, 2006
Modular, multifunctional U2300A Series consists of 7 modules with up to 64 analog input channels and up to 3 MS/sec sampling rate for single channel. Allowing expansion up to 384 channels, 6-slot Agilent U2700A Series USB Modular Instrument Chassis connects up to 6 U2300A modules, is mountable to rack-mount kit, and provides star trigger bus synchronization. Both devices feature plug-and-play setup and USB 2.0 interface.
|
DAC offers 6 software-programmable output ranges.Linear Technology Corp.
Milpitas, CA 95035
Nov 20, 2006
Operating from dual ±5-±15 V analog supplies and 3-5 V digital supply, 16-bit quad Vout Model LTC2704-16 features DC performance of ±2 LSB INL and ±1 LSB DNL. Each of 4 DACs can be programmed via 3-wire SPI-compatible serial interface for 1 of 4 bipolar output ranges or 1 of 2 unipolar output ranges. Reference input voltages are inverted internally and can be driven to 7.25 V, producing output swings up to ±14.5 V. Output ranges include ±10 V, ±5 V, ±2.5 V, -2.5 to 7.5 V, 0-5 V, and 0-10 V.
|
 UV Luminescence Sensor has long-range, high-speed operation.Balluff, Inc.
Florence, KY 41042-0937
Nov 17, 2006
Able to detect UV luminescent materials/markers over distances to 300 mm, BLT 31M combines adjustable light projection and high resolution to suit part detection and error proofing applications. Sensing range helps avoid incidental contact in manufacturing process, while 6 kHz response time suits high-speed applications. With optional 50 mm lens, projected light can be directed into 5 mm spot. Sensor includes auto-teach and manual programming as well as analog and discrete outputs.
|
 Liquid Flow Meters include onboard display.Racine Vortex Flow Meters / Div. of Racine Federated Inc.
Racine, WI 53406
Nov 17, 2006
Wafer-style, Series RWL offers access to programmable software, 10-point linearization, and diagnostic tools through external keypad. Vortex meters are available as loop-powered devices with 4-20 mA output and fit pipe sizes from 1-3 in. They may be configured for 3-wire frequency pulse output as well. Utilizing ultrasonic sensing technology, Series RWL produces accurate flow measurements of most low viscosity liquids with low pressure drop.
|
 Air Monitoring System provides FTIR gas analysis.Midac Corp.
Irvine, CA 92614 6016
Nov 17, 2006
Featuring sealed 0.5 cm-1 resolution interferometer with choice of beamsplitters and detectors, AM Air Monitoring System can detect, identify, and measure wide range of compounds simultaneously within seconds of startup. Analysis is onsite through continuous sampling path up to 1,000 m. Analyzer is coupled to control PC via ribbon cable or long range fiber optic link. For extended sample paths, FTIR can be mounted to 10 in. Newtonian telescope with tripod.
|
 Incremental Encoders are programmable by end users/OEMs.SICK STEGMANN, INC.
Dayton, OH 45413
Nov 17, 2006
Using USB connection and programming software, 60 mm dia DRS61 CoreTech® Incremental Encoders let users program number of lines from 1-8,192 as well as width of zero pulse. Modular design allows use of one type of encoder that can be programmed at any time, in any location, for any application. Encoders are offered in face mount flange, servo flange, blind, or through hollow shaft with connector or cable outlet, TTL, or HTL interface configurations.
|
Multichannel ADC offers programmable input ranges.Linear Technology Corp.
Milpitas, CA 95035
Nov 17, 2006
Capable of speeds to 100 kS/sec, LTC1859 incorporates 8-channel multiplexer that can accept 4 differential inputs, 8 single-ended inputs, or combinations of both. Software-programmable inputs are fault-protected to ±25 V, and dc performance is 15-bit no missing codes over temperature and ±3 LSBMAX INL. Internal 2.5 V reference has temperature coefficient of ±10 ppm/°C and can be externally driven. ADC operates from single 5 V supply and consumes 40 mW.
|
Vision Appliance suits single camera applications.ipd, the intelligent products division of Coreco Imaging, Inc.
Billerica, MA 01821
Nov 17, 2006
Housed in DIN mountable enclosure, Model VA15 features remote small-format camera with 640 x 480 sensor resolution. State of each input and output is reflected by associated LED on front of unit. Pre-installed iNspect software is exposed through standard web browser on connecting network computer, providing connect-and-go capability. Appliance is equipped with Gigabit-compliant network connection that allows real-time image feed to web browser.
|
(Showing headlines 9301 - 9320) << 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760
|
|
|