|
|
|
|
|
Test & Measuring Instruments
(Showing headlines 8601 - 8620) << 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 ...
|
 Gas Standards Generator utilizes modular, 2-stage dilution.Kin-Tek Laboratories
LaMarque, TX 77568 4202
Apr 27, 2007
Modular gas standards generator 491M/B/SD dynamically blends precisely known VOC/TOC gas standards with parts-per-billion and parts-per-trillion analyte concentrations. In first stage, 491M/B combines analyte flow from Trace Source(TM) permeation tubes with precisely controlled flow of pure dilution gas to form parts-per-billion concentration mixture. Second stage, 491M/SD, further dilutes aliquot of ppb mixture to form part-per-trillion mixture.
|
 Ground Fault Sensing Module protects outlets on generators.Bryant Electric
Milford, CT 06460 2465
Apr 27, 2007
Functioning interdependently with magnetic branch circuit breaker, GFCI module monitors electrical circuit by use of external differential current transformer. No direct load is present at module, and in case of ground fault, load is interrupted by way of circuit breaker utilizing shunt trip coil. Available with automatic or manual safe start reset feature, unit is rated from 1-15 A and is suited for circuit-carrying conductors from 1-3 poles.
|
 Data Capture Unit measures various pallet shapes and sizes.Mettler Toledo, Inc.
Columbus, OH 43240
Apr 27, 2007
With OIML approved accuracy of ±0.75 in., CSN840 Pallet(TM) automatically collects dimensions, weight, and identification of large goods. Unit processes about 200 pallets/hr and features overhead, non-intrusive design that can be floor, wall, or ceiling-mounted. Graphical interface provides clear overview of measuring process and historical measurement statistics. Communication with host computer or warehouse management system is achieved via Ethernet or serial communication.
|
 Hydraulic, Hand Operated Test Stand has 20-ton capacity.C.M. Mockbee Co., Inc.
Cincinnati, OH 45223
Apr 27, 2007
Capable of static and dynamic testing, Mockbee 20 ton test stand can be operated in vertical or horizontal applications via its 2-stage, hydraulic hand pump. It is designed for testing hoisting equipment as well as other related lifting equipment after repair or inspections are performed as required by ASME Code B30.16. Stand also tests function of overload devices. Components include reinforced steel frame, fine-adjustment pressure valve, and 4.0 in. dia pressure gauge.
|
 Bargraph Process Meter provides relays for alarm or control.Laurel Electronics, Inc.
Costa Mesa, CA 92626
Apr 27, 2007
Available with two 5 A, 250 Vac contact relays, Model BAR Bargraph Process Meter fits into 1/8 DIN panel meter cutout. It provides bar graph display of industrial process signals such as 4-20, 0-20, and 0-10 mA, and 1-5 or 0-10 V. Bar graph consists of 30 LED elements which are offered in either red or green. Designed for industrial environments, unit is immune to EMI, and features environmentally sealed to NEMA-12 (IP54) front panel.
|
 PCI DAQ Card offers up to 250 kS/s sampling rate.ADLINK Technology Inc.
Irvine, CA 92618
Apr 27, 2007
With WDM driver for C/C++, VB, Delphi, C++ Builder, and .NET programming languages and full device drivers for MATLAB® and LabVIEW®, Model PCI-9221 multi-function, 16-bit resolution DAQ card targets test and measurement system integrators and laboratories. Unit features single-button auto-calibration, programmable I/O supporting digital I/O (TTL), general-purpose timer/counters, motor encoder inputs, and PWM (pulse width modulation) outputs for motion control.
|
 Incremental Encoder is customer-programmable.SICK STEGMANN, INC.
Dayton, OH 45413
Apr 27, 2007
Allowing users to freely program width of zero pulse and number of lines from 1-8,192, Model DRS26 CoreTech® Incremental Encoder can be programmed at any time, in any location, for any application. Offered in 2.5 in. housing, it features opto-ASIC with chip-on-board technology and automatic light regulation. Square flange, servo flange, and face mount versions are available with 0.25 and 0.375 in., and 10 mm solid shafts.
|
Wind Measurement Instruments suit commercial applications.Maximum, Inc.,
New Bedford, MA 02745
Apr 27, 2007
Able to record speeds in excess of 200 mph, wind speed sensors are available with voltage, frequency, or pulse counting outputs and feature black Lexan cups that resist and shed ice. Handheld anemometer, offered in battery (DIC-3) and self-powered (BTC) models, features 3 cups to obtain accurate readings regardless of position. Also available, wind alarms provide warning for and control of wind-sensitive equipment via thumbwheel switch-selectable speed level thresholds.
|
Air Monitoring Products measure ventilation, air quality.TSI, Inc.
Shoreview, MN 55126-3996
Apr 27, 2007
Along with integral display for viewing measurements, thermal anemometers come with LogDat2 software package for data logging and reporting. USB data downloading and wireless Bluetooth printing are also standard. Capable of real-time measurements, Indoor Air Quality instruments let users save data and review statistics on same compact unit. Products serve building service contractors, commissioning specialists, facility engineers, and research professionals.
|
Field Transmitter wirelessly relays remote sensor signals.VEGA Controls Ltd
West Sussex RH15 9NF United Kingdom
Apr 27, 2007
PLICSRADIO field transmitter accommodates up to 3 transmitters and 2 switches, using combination of 4-20 mA HART and 2 digital relay or NAMUR inputs, and can also provide power to sensors. ATEX-approved device has range potential of 1.6 km and features in-head display to show radio signal strength and data. Configuration and diagnostics are accomplished using internal programmer, or can be done remotely via PC using FDT/DTM and PACTware software.
|
Viscosity Sensor features USB connectivity option.Vectron International
Hudson, NH 03051
Apr 27, 2007
Suited for process control environments, ViSmart(TM) provides instantaneous sample and/or continuous, real-time, in-process measurements of fluids from 1-500 cps. USB connectivity enables unit to be attached to any likewise-equipped computer platform for immediate acquisition of viscosity and temperature data (125°C max). Unaffected by vibration or flow conditions, solid-state sensor uses semiconductor technology and is sealed for complete immersion.
|
 Vision Sensors speed inspection time.Cognex Corp.
Natick, MA 01760 2059
Apr 26, 2007
In-Sight® 5600 Series includes standard, 640 x 480 resolution model as well as 2 megapixel, 1,600 x 1,200 models that perform in high-speed applications. All units have IP67 rating to withstand dust and washdown without accessory enclosure. Library of advanced vision software is provided for inspection, identification, measurement, and alignment tasks.
|
 Power Monitor measures 70 types of variables.Absolute Process Instruments Inc.
Libertyville, IL 60048
Apr 26, 2007
Designed for continuous electrical power measurements in distribution systems or industrial facilities, SINEAX CAM provides basic accuracy of ±0.1% for voltage and current and ±0.2% for other variables. Unit measures RMS voltage, current, active power, reactive power, apparent power, power factor, frequency, unbalance, harmonics, and energy. Simultaneous measurement of all 3 phases captures every change or disturbance as fast as every cycle with time-stamped min/max values.
|
Delta-Sigma ADC includes internal temperature sensor.Linear Technology Corp.
Milpitas, CA 95035
Apr 26, 2007
Housed in 4 x 3 mm DFN package and consuming 300 µA, 4-channel LTC2493 measures 4 single-ended or 2 differential analog inputs, and communicates over 2-wire, I2C-compatible serial interface. It performs conversions at rates of 15 Hz or 7.5 Hz while using internal oscillator. Easy Drive(TM) technology enables rail-to-rail inputs with zero differential input current. Offering 1/30°C resolution and 2°C absolute accuracy, temperature sensor enables temperature compensation of external sensors.
|
 Digital Panel Meter can be read from a distance.Dwyer Instruments, Inc.
Michigan City, IN 46361
Apr 26, 2007
Designed with 3˝ digital LCD display, Series DPMP-5 offers choice of red, amber, or green segments. It features adjustable zero and span, selectable decimal point position, and selectable 12 Vdc or 24 Vdc power supply. User can field-select engineering units to fit variety of applications. Snap-in bezel allows installation without additional mounting hardware.
|
Voltage-to-Pressure Transmitter can be used with natural gas.Moore Industries International, Inc.
North Hills, CA 91343
Apr 26, 2007
Supplied in NEMA 4X explosionproof housing, 3-wire EPX2 Voltage-to-Pressure (E/P) transmitter is designed for use with normal instrument air and can also be used with natural gas. Product accepts voltage input signal from DCS, PLC, or PC-based control system and converts it to pneumatic signal for control of valves, actuators, and other pneumatically controlled devices. Accuracy is ±0.25% of span, maintained in supply pressure fluctuations from 20-40 psig.
|
 Digital Refractometer provides 0-65% range.Kernco Instruments Co., Inc.
El Paso, TX 79927 7338
Apr 25, 2007
Utilizing microprocessor technology, portable Model 300051 operates at sample temperatures up to 40°C and provides 8,000 readings on single AAA alkaline battery. Device includes automatic temperature compensation from 41-104°F and automatic shutoff after 3 min if not in use. Water-resistant design protects electronics from wet environments and facilitates clean up. With measurement time of 1 sec, instrument delivers ±0.2% accuracy and 0.1% resolution.
|
 Pressure Transmitter handles demanding applications.ABB Instrumentation
Warminster, PA 18974
Apr 25, 2007
To eliminate traditional leak paths, Model 364 pressure and differential pressure transmitters are designed with no bolts, gaskets, and flanges. Features include all-stainless steel housing and process connection along with Hastelloy® C-276 diaphragm for corrosive process media. Base accuracy is 0.06% and stability is ±0.15% of maximum span for 10 yr period. Along with LCD display that includes Easy Setup menu configuration, unit also offers built-in surge protection.
|
Gas Allocation Device suits multifamily properties.Integrated Metering Systems Inc.
Pinellas Park, FL 33782
Apr 25, 2007
Compatible with Inovonics TapWatch® submetering system and Commercial-Mesh(TM) Network, HVAC Pro-E is designed to accurately allocate gas consumption of furnaces, fan coil broiler/chiller systems, baseboard, and individual domestic hot water tanks. Product provides multifamily properties with tool for submetering central heating and cooling systems, allowing owner to cut operating expenses.
|
Test System assesses MediaFLO compliance.Rohde & Schwarz GmbH & Co
Germany
Apr 24, 2007
Conformance test system, TU8980, enables manufacturers to evaluate mobile handsets for compliance with MediaFLO(TM) minimum performance specifications published by TIA as well as any additional performance requirements emphasized by service providers. Built with CMU200 Universal Radio Communication Tester and SFU Broadcast Test System, solution is available as full conformance test system for FLO I and can be extended for FLO II and FLO III as well.
|
(Showing headlines 8601 - 8620) << 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754
|
|
|