 Optical Strain Gage comes with plastic encapsulation.HBM, Inc.
Marlborough, MA 01752 3014
Jun 09, 2009
With ability to make sensors highly resistant to mechanical damage, optical K-OP strain gages reach 10 mil stress cycles in continuous vibration behavior with alternating strain of ±3.000 µm/m. Unit is available with data sheet containing necessary data, such as gage factor for strain measurements. It is suited for measurements in hazardous areas and in high current and voltage engineering components.
|
 Gas Monitors help detect or monitor hydrogen peroxide.Interscan Corp.
Chatsworth, CA 91313
Jun 09, 2009
Offered in range of portable survey monitors to permanently installed multipoint systems, hydrogen peroxide monitoring instruments feature full data acquisition, archiving, and reporting capability. Products come with minimum detectability of 0.05 ppm, and full scale ranges up to 0-1,000 ppm. Suitable applications include sterile processing departments and bio-decontamination in health care industry.
|
Converter handles HDTV video signals.Atlona Technologies
San Jose, CA 95131
Jun 09, 2009
Model AT-COMP500 Composite Video Down Converter takes component HDTV video signals up to 1080p and down converts them to composite and S-video signals simultaneously. Conversion is applicable in PAL or NTSC formats and component video pass-through connection is supported. Unit can remain powered on and enables HD to be integrated into various touchpanels in any commercial application.
|
Analog I/O Modules provide 16-channel 16-bit A/D interface.Acromag, Inc.
Wixom, MI 48393 7037
Jun 09, 2009
Model 993EN BusWorks® Ethernet I/O modules accept DC current with ±20, 0-20, or 4-20 mA input ranges, while 994EN units accept ±5 or ±10 Vdc. Available in industrial-grade or commercial versions, 1 in. wide devices feature dual-format data registers supporting 16-bit integer and 32-bit floating point formats. Surge protection and 3-way 1,500 V isolation between I/O, power, and network circuits optimize reliability. Modules are configurable via web browser.
|
X-Ray Image Detector suits angiography equipment.Varian Medical Systems, Inc.
Palo Alto, CA 94304
Jun 09, 2009
Operating at speeds up to 30 fps, PaxScan® 3030+ lets physicians monitor interventional procedures, including placement of catheters within blood vessels, in real-time. Multi-modality panel is also designed for use in cardiovascular imaging systems and surgical C-arms. While 194 micron pixel pitch results in images with enhanced contrast resolution and no distortion, cesium iodide scintillator optimized for scanning at 40-150 kV minimizes X-ray dose to patient.
|
IC operates as capacitive sensor signal conditioner.ZMD
Dresden Germany
Jun 09, 2009
ZMD31210 cLite(TM) delivers 14-bit resolution and can be configured to interface with capacitive sensors from 2-260 pF with sensitivity as low as 125 atto-Farads/digital bit. Standard supply is 2.7-5.5 V with accuracy of 0.25% over -20 to +85°C range, and 0.5% from -40 to +125°C. ZMD31210 connects to micro-controllers but can also be utilized in stand-alone designs for transducer and switch applications, and calibration coefficients are stored in an on-board non-volatile EEPROM.
|
 Test Module verifies DSL-based triple play services.Sunrise Telecom Inc.
San Jose, CA 95119
Jun 08, 2009
When combined with MTT Advanced Cable Maintenance chassis, UDSL-3Play Module enables telecom service providers to verify copper infrastructure and triple play IP services delivered over Universal DSL access network. Module provides both customer premises and central office DSL modem emulation, as well as IP data connectivity and throughput test to determine Internet access and overall QoE. Single button DSL test automatically presents summary screen of key metrics.
|
 I/O Controllers handle USB's complex protocol details.Saelig Co., Inc.
Pittsford, NY 14534
Jun 08, 2009
Appearing as Human Interface Device, Warrior ICs require no Windows software drivers. IO-Warrior56 features 50 pins that can be used as direct I/O lines, or more complex functions, such as I2C, SPI, controlling display modules, 8x8 switch matrices, and IR remote control decoding. IOW56 can run I2C master interface at 100 Kbps, with clock stretching for handshaking with slaves supported. SPI master function allows max bit rates of 12 MHz and peak data throughput of 62 KBps.
|
 Portable Video Probe has VGA video output.GE Sensing
Billerica, MA 01821
Jun 08, 2009
Featuring 1 Gb of internal flash memory and single USB® 2.0 port, XL Vu is designed for basic inspection where operators need a quick view of hard to access areas. Featuring servo motor All-Way® Probe articulation, ac corded or upgraded battery powered options, and full tip optic interchangeability with secure double threads, unit suits applications in oil and gas, power, automotive, security, and aerospace industry.
|
 Handheld Digital Manometer suits field, plant, and lab use.Omega Engineering, Inc.
Stamford, CT 06907
Jun 08, 2009
Available in gage and absolute and differential pressure models with ranges as low as 28 InH2O, HHP241 features 8 user selectable engineering units, min/max, hold, and display average modes with user activated back light. CE compliant device shuts off automatically after 20 min of keypad inactivity.
|
XRD/XRF Instrument is suited for art conservation analysis.inXitu Inc.
Mountain View, CA 94043
Jun 08, 2009
Designed as portable, combined XRD/XRF instrument, Duetto is used for phase/mineral and elemental identification of delicate materials (such as art work) or items too large to be brought into laboratories. This non-destructive analysis tool allows x-ray diffraction and fluorescence data to be obtained from one location on artifact, without touching it. Applications include paintings, manuscripts, and sculptures.
|
 Infrared Temperature Sensor suits autosports applications.Variohm Components
Towcester Northamp NN12 6HP United Kingdom
Jun 05, 2009
With 150, 200, and 800ºC temperature ranges, ETIS series is designed for demanding tire, brake, and exhaust temperature measurement in autosports. It has 1,000 G shock rating and is packaged in lightweight aluminum housing measuring 20 x 18 x 12 mm and weighing 26 g. Available with front facing M3 fixing holes and 1 m long shielded leads, unit operates in ambient temperatures between 0-120ºC with 30-70 mm measurement stand-off distance and target area of approximately 20 mm dia.
|
 Fiber Optic Power Meter tests power within 800-1,600 nm.GAO Tek Inc.
Toronto M1B2K4 Canada
Jun 05, 2009
Featuring 3 modulated signals, auto-wave recognition, low-power consumption, and large LCD screen, ruggedized fiber optic power meter GAO560 is suited for field testing. It can automatically recognize wavelength and offers testing range between -70 and 10 dBm, while moveable connector enables several types of connections, including FC and SC. Product can be combined with optical light sources and visual fault locators for testing fibers with different wavelengths simultaneously.
|
 Gateway Module enables EtherCAT real-time data acquisition.HBM, Inc.
Marlborough, MA 01752 3014
Jun 05, 2009
QuantumX CX27 gateway module makes it possible to connect several QuantumX models in real-time via EtherCAT to superordinate automation system. With cycle times under 1 msec, measurement data can be rapidly integrated with Gateway module in automation routines and in parallel measurement and analysis processes. System allows data acquisition and control of test benches to be integrated in test bench itself in order to ensure precise data synchronization.
|
 Ozone Tester determines ozone resistance of rubber.Qualitest International Inc
Fort Lauderdale, FL 33308
Jun 05, 2009
Based on Beer-Lambert law to inspect ozone concentration without use of chemicals, QT-0500 ozone tester provides automatically controlled ozone concentration environment for evaluating resistance of rubber products to cracking during service life. Generated by 185 nm UV-lamp, ozone can be controlled between 0-1,000 pphm for model QT-0500 or 200-30,000 pphm for model QT-0500AC. Temperature can be controlled between 68-194°F, and set values are maintained by PLC control system.
|
 Gas Flow Meter features rotatable scale drum.Aalborg Instruments
Orangeburg, NY 10962
Jun 05, 2009
Capable of measuring flow rates of argon, carbon dioxide, helium, nitrogen, and oxygen, Model xV multi-gas glass tube flow meter is available as vertical in-line or panel mount models. It comes with 3/8 in. NPT female in-line or rear connections as well as 316 SS floats. Readable direct reading gradations showing dual SCFM and L/min markings reflect both metric and English systems. Standard seals are Viton® with optional Buna-N®, PTFE/Kalrez® and EPR seals available.
|
Data Logger permits multiple logs to be recorded/read back.Micro Digital, Inc.
Costa Mesa, CA 92626
Jun 05, 2009
Supporting NAND, NOR, serial NOR, and arrays, smxFLog(TM) flash logger works with flash memory of any size. It is power-fail safe and offers memory of 2-4 KB code and 32-288 bytes of RAM, but provides wear leveling, bad-block handling, read back and verify, and block erase. Write speed/read speed are over 69%/86% of raw flash speed, respectively. Minimum record size can be adjusted to characteristics of flash device and each log can stop at end of partition or overwrite oldest information.
|
Multi-Functional Network Tester offers 20 M memory capacity.GAO RFID Inc.
Toronto Canada
Jun 05, 2009
Allowing users to download test results directly to PC or USB disk drive, GAO321 tests cable length, breaks, and swinging cross with maximum distance of 150 m. It offers TFT LCD for viewing test results, supports Ping, Ipconfig, Tracert, and Route network layer tests, and also tests ac or dc voltage, line capacitance, and line insulation. Unit combines all practical functions of testing instruments such as Time-Domain reflectometer and digital multimeter into single device.
|
Data Acquisition Module features parallel design.GAO Instruments Inc.,
Toronto Canada
Jun 05, 2009
Designed for embedded use as standard PC104 card, data acquisition module features 12-bit analog-to-digital resolution with 8 single ended inputs ranging from 40 mV to 40 V. It comes with 2 independent programmable gain channels and has sampling rate from 1 k to 20 m with low inter-channel phase difference of less than 1°. Module offers selectable/adjustable manual, external/internal triggering modes on conditions of rising and falling edge.
|
Evaluation Board is based on TMS320F2812 DSP.GAO Embedded Inc.
Toronto 12345 Canada
Jun 05, 2009
Available with driver and control systems, 2812EVM-II DSP evaluation board provides CLK, CS2, CS2, CS6, RD, WR, CS1571, RS1581, EVA, EVB, IN1 to IN8, OUT1 to OUT8 signal testing and debugging points. It provides users with on-board VL-Bus and data, address, control access terminals, and EMI from computing unit is avoided by using independent power supply. Other features include on-chip flash program memory, extended SARM, 8 LEDs, and RS-232 interface for PC communication.
|
(Showing headlines 5141 - 5160) << 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 ...
|
|
|