 Explosion-Proof Pressure Transmitter is accurate to ±0.075% FS.Dwyer Instruments, Inc.
Michigan City, IN 46361
May 14, 2010
Programmable using HART® Communication, Series 3200 Smart Pressure Transmitter is microprocessor-based and features flexible pressure calibration as well as pushbutton configuration. EEPROM stores configuration settings and stores sensor correction coefficients in event of shutdowns or power loss, and transmitter software compensates for thermal effects. FM approved for use in hazardous (classified) locations, product offers 100:1 rangeability to fit any application.
|
 Absolute Encoder comes in compact modular package.CUI, Inc.
Tualatin, OR 97062
May 14, 2010
Measuring only 1.35 x 1.13 x 0.45 in., AMT203 outputs 12 bits of absolute position information using patented capacitive code generation system and on-board PIC 16F690 MCU that operates at up to 2 MHz. Encoder consumes 10 mA max at 5 Vdc, and is available with 9 mounting patterns and 10 bore size options. Device also provides non-magnetic index pulse and may be configured to output incremental position data after zero position is established to approach throughput of up to 10 MHz.
|
Melting Point Apparatus supports simultaneous sampling.Dynalab Corp.
Rochester, NY 14623
May 14, 2010
Speeding process of determining melting points, SMP30 can take 3 samples simultaneously within optimized heating block. It has max temperature of 400°C and variable ramp rate from 0.5°C to 10°C in 0.1°C increments. Tubes are illuminated with bright white LEDs, resulting in clear view of samples during melt. Menu system, used to guide operators through melting process, is displayed on backlit alphanumeric LCD. It is possible to record up to 8 events in memory for each of 3 sample tubes.
|
 Screw Counter detects fastening errors in assembly process.Mountz, Inc.
San Jose, CA 95112
May 13, 2010
Designed to detect cross-threading, omissions, unfinished rundowns, and cycle completes, Scout Screw Counter ensures assembly process is done correctly. Unit operates jointly with Mountz electric screwdrivers and STC30 or STC40 power supply. With 4 ports on side, maximum of 4 screwdrivers can share one program with unit. Programmed via PC software or manually through keypad, Scout alerts operator with buzzer and red light if fastening error is detected.
|
 Inclinometer System suits construction and shipbuilding.Columbia Research Labs., Inc.
Woodlyn, PA 19094
May 13, 2010
Designed for differential tilt measuring, Model DI-10-DFD-IR allows matching slope of 2 remotely located surfaces. Readout can be set to indicate absolute tilt of either sensor or differential angle between them. Display provides 4½ digit, 7 segment, 0.4 in. high readout indicating +10.000° full scale. Measuring 3.64 x 2.10 x 1.69 in., sensors supplied with system feature aluminum case, operate from -20 to +75°C, and their shock survival is 50 G RMS.
|
 Dual Range Gloss Meter offers ultra high gloss measurement.Paul N. Gardner Co., Inc.
Pompano Beach, FL 33060 6608
May 13, 2010
Offering 2 user-selectable measurement ranges, Model IG-410 measures low gloss samples using 0-100 range and high gloss samples, such as polished metal and mirror finishes, using 0-1,000 range. Portable, battery-operated instrument is supplied with 2 calibration plates, which allow one-touch calibration for reproducible results.
|
 Process Control suits small oven or autoclave applications.CompuDAS
Shelton, WA 98584-8759
May 13, 2010
With 2 analog output channels, 10 digital I/O connections, and up to 8 analog I/O, CPC-8 data acquisition and critical process control provides communication utilizing Windows-based software and Ethernet connectivity. CompuDAS CDClave software allows for oven and autoclave control by specific customer-defined recipes of up to 20 segments. Software also offers optional control of lagging or leading part temperatures. With secure PC connection, users can monitor processes remotely.
|
 Multifunction Thermometer measures barometer/dew point/RH.Control Co.
Houston, TX 77258 8307
May 13, 2010
Available in rugged ABS plastic case measuring 1½ in. dia x 8 in., Traceable® hygrometer/thermometer/barometer/dew point pen has user selectable dual display that shows humidity/temperature, humidity/dew point, barometer/temperature, or barometer/humidity. Features include electronic capacitance polymer film sensor, HOLD button that freezes reading on display, and 3/8 in. high LCD digits. Product can recall minimum/maximum readings on press of button.
|
 4-20 mA Adapter Board is developed for commercial users.Phidgets, Inc.
Calgary, AB T2M3R7 Canada
May 13, 2010
Targeted for commercial customers, Model 1132 allows users to integrate 4-20 mA industrial sensors into their projects. Any 4-20mA sensor that does not require more than 15 V and whose capacitive load is equal to or less than 1.5 µF can be used. Output impedance is 1 KW and current consumption is 130 mA in 22 mA loop, 18.4 mA in 4 mA loop, and 1.84 mA at no load. Features include power supply range of 4.75-5.25 Vdc and max output error of ±1.2%.
|
 Flap Type Flowmeter is available for pipe sizes from ¼-8 in.PKP Process Instruments, Inc.,
Hudson, MA 01748
May 13, 2010
Available with G or NPT threads for pipes and as wafer for mounting between 2 DIN or ANSI flanges on DN80 (3 in.) to DN200 (8 in.) pipe sizes, model DK10 Flow Meter operates at up to 2,900 psi of pressure and in temperatures up to 625°C. Spring-loaded flap mounted in hemispherical chamber gets deflected by flow in line, and deflection is directly proportional to flow rate. Unit is available with 1 or 2 alarm level outputs as well as 4-20 mA output proportional to flow.
|
 Tank Level Gauges and Switches suit cryogenic/liquefied gas.Mid-West Instrument
Sterling Heights, MI 48314
May 13, 2010
Available in single and double switch options, Model 116 indicating switches feature Dry Bellows design with internal bi-directional relief valves with no liquid fill required to protect unit from over-range. DP ranges from 0-80 in. H2O to 0-600 in. H2O. Rated at 4 A at 30 Vdc, 5 A at 120 Vac SPDT, units come with highly visible Flag option to indicate "reorder" or "alarm" fluid conditions, and custom dial faces (logo, dual or tri scale).
|
Fiber Optic Talk Set supports online display and call.GAO FiberOptics Inc.
Toronto Canada
May 13, 2010
Combining digital optical phone and stable light source, model 08311 aids installation, optical testing, maintenance, and fiber attenuation value testing in data networks, CATV, and telecom networks. It deals with 1,310 or 1,550 nm wavelength signals and carries out full-duplex communication. With output power rated from -5 to -7 dBm, product features 7-color, backlit LCD screen for clear display of operations and offers 270 Hz, 1 kHz, 2 kHz, and CW modulation frequencies.
|
 Nitride Lever Probes enable high-resolution AFM imaging.Veeco Instruments Inc. Corporate Headquarters
Woodbury, NY 11797
May 12, 2010
Able to be used on any atomic force microscope (AFM), Sharp Nitride Lever (SNL) Probes feature tip that combines low spring constant softness of silicon nitride cantilever with sharpness of silicon tip. This results in radius of curvature as low as 2 nm. High resolution imaging in air and fluid is possible using Contact Mode and TappingMode(TM) operation, and there are 2 available configurations: NP/DNP levers and MLCT/MSCT levers. All products are built for extended lifetime.
|
 Signal Recording Instrument synchronizes two 16-bit channels.Pentek Inc.
Upper Saddle River, NJ 07458
May 12, 2010
With up to 4 TB of removable RAID storage and dual 200 MHz, 16-bit sampling channels in 4U rack-mount unit, Model RTS 2703 forms complete Windows XP workstation that can stand alone or connect to gigabit Ethernet network for remote access and control. Both sampling channels deliver nearly 90 dB of spurious free dynamic range and use same start, stop, triggering, and clock timing to ensure that data sets are synchronized. NTFS recording format simplifies file access and eliminates conversions.
|
 NCIMS-Approved Somatic Cell Counter uses LED light source.Advanced Instruments, Inc.
Norwood, MA 02062
May 12, 2010
Approved by Lab Committee of the National Conference on Interstate Milk Shipments (NCIMS), SomaScope(TM) Smart incorporates flow cytometer and LED technology. LED illuminates stained cells in sample, and dual photomultiplier tubes detect cells. Resultingly, there are no warm-up wait times and no light source hot spots. Along with 30 sec analysis time, functional efficiency is promoted via wizard-driven software. Calibration exceeds IDF/ISO/FDA/NCIMS standards.
|
 Optical Attenuator Module is designed for GP750 test system.Dicon Fiberoptics Inc.
Richmond, CA 94804
May 12, 2010
Fiber optic attenuator module can automate optical switches and fiber optic attenuators with complete plug-and-play modularity and control options. Product can be used with single mode fiber and can support up to 8 optical attenuators in single 1-wide GP750 module. Max attenuation level can be specified up to 40 dB of attenuation, and can also be specified for narrowband or broadband use in 1,290-1,330 nm, 1,530-1,570 nm and/or 1,570-1,610nm wavelength ranges.
|
 Smart Camera suits single point machine vision inspection.DALSA
Waterloo, ON N2V2E9 Canada
May 12, 2010
Housed in rugged, easy-to-mount enclosure, monochrome model BOA M1280 delivers high resolution of 1,280 x 960 and operates at up to 24 frames/sec. Camera incorporates multiple processing engines, providing algorithm optimization via DSP, application management via CPU, and sensor management via FPGA. Eliminating version control problems, camera comes with truly embedded application software, which is set-up through standard web browser.
|
 Temperature Sensor has 4 stripped lead thermocouple inputs.Phidgets, Inc.
Calgary, AB T2M3R7 Canada
May 12, 2010
Able to obtain temperature in °C for K, J, E, and T-Type thermocouples at rate of 25 S/sec, 1048 - PhidgetTemperatureSensor delivers thermocouple resolution of 0.1°C (K-type at 25°C) and 4 µV, with accuracy of 2°C (K-type). Sensor connects directly to computer's USB port, and features current consumption of 25 mA and USB device voltage of 4.75-5.25 Vdc. Users can program device using API supported under Windows 2000/XP/Vista/CE, as well as Mac OS X and Linux.
|
 Electrolytic Tilt Sensor offers sub arc-sec measurement.Fredericks Company, The
Huntingdon Valley, PA 19006-6232
May 12, 2010
High Accuracy Electrolytic Tilt Sensor (Part #0737-1203-99) utilizes thin film technology to provide inclination measurement with arc-sec repeatability. Sensor offers angle range of ±30 arc-min, less than 0.05 arc-sec resolution and less than 0.5 arc-sec repeatability at null. Featuring hermetic seal design for operation in extreme conditions. applications include geophysical monitoring, surveying equipment, aircraft avionics, machine tool leveling, among others.
|
 Precision Measurement Microphones meet IEC/ANSI standards.Meggitt Sensing Systems (Endevco Corp.)
San Juan Capistrano, CA 92675
May 12, 2010
Available in 1/8, ¼, and ½ in. dia, Endevco® prepolarized condenser measurement microphones are offered in free-field, pressure, low-cost array, and random incidence types. All microphones are constructed with stainless steel protective grid case and housing, as well as special stainless steel alloy diaphragm, to suit variety of application environments. Models are offered as stand-alone units, or in microphone and low-noise preamplifier combination with iTEDS on-board memory storage.
|
(Showing headlines 3621 - 3640) << 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 ...
|
|
|