Test & Measuring Instruments
(Showing headlines 13961 - 13980) << 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 ...
|
 Controller takes LabVIEW into harsh environments.National Instruments Corp.
Austin, TX 78759-3504
Nov 15, 2002 Compact FieldPoint consists of 20 I/O modules and 3 intelligent controllers that perform analog and discrete control, user-defined data logging, and inline math and signal processing. Solid metal backplane with 4 or 8 slots withstands 50 g of shock and 5 g of RMS vibration. Ethernet connectivity allows remote monitoring of sites, while built-in Web and file servers provide access to embedded LabVIEW application and stored data. RS-485 and RS-232 serial ports control external devices. |
 Digital Pressure Gauge displays reading from 0–1,000 bar.Enerpac (Industrial Tools)
Milwaukee, WI 53201 3241
Nov 15, 2002 Battery-operated Model DGR-1 provides up to 1,400 hrs of continuous operation. Gauge displays pressure readings in hydraulic system with accuracy of 0.2% of FS. Display can be changed to read in psi, Mpa, kPa, mbar, and kg/cm² by pressing one button. Built to resist contamination during use, IP65-rated gauge includes automatic shut off, maximum and minimum pressure capture, zero reset, and 355° display rotation. |
X-ray Microanalysis System utilizes various sensor types.EDAX, Inc.
Mahwah, NJ 07430
Nov 15, 2002 GENESIS XMS employs LN Free Si(Li) Detector, Silicon Drift Detector, and 2 versions of WDS spectrometer, which compliment system's proprietary LN Cooled Si(Li) Detector. All detectors are compatible with Pegasus EDS-EBSD systems for microanalytical materials characterization. GENESIS XMS is capable of accepting input count rates in excess of 500,000 counts per second. |
Barometer is safe alternative to mercury instrument.Allivan Marketing
Tyngsboro, MA 01879
Nov 15, 2002 Consisting of 64 in. U-shaped tube filled with red, non-toxic silicon fluid and gas, Eco-celli® Barometer is mercury-free liquid barometer that is as accurate as standard liquid barometers but contain no hazardous material. Scale slides between 32 in. methyl-alcohol thermometer and barometer to compensate for thermal expansion of silicon fluid due to changes in room temperature and provides accurate, easy-to-obtain results. |
 Data Logger/Controller suits low-power applications.Onset Computer Corp.
Bourne, MA 02532
Nov 14, 2002 Embedded Model TFX-11v2 provides 19 analog channels, 24 digital lines, 2 UARTs, up to 6.4 kHz sampling rate, and 2 Mbyte of Flash EEPROM memory. Minimum current draw is less than 100 µA in low-power mode with up to 150 mA available for data acquisition or control tasks. Unit measures only 1.2 x 2.75 x 0.50 in. Logger/controller is user-programmed in Windows®-based TFTools Integrated Development Environment using TFBASIC. |
 Coordinate Measurement Machine provides easy portability.FARO Technologies, Inc.
Lake Mary, FL 32746 6204
Nov 14, 2002 Titanium FaroArm® provides measurement capabilities, with accuracy to .001 in., to inspect, reverse engineer, or perform CAD-to-Part-analysis on parts, fixtures, and assemblies. Series interfaces with all FARO CAM2® software and includes universal 3.5 in. mounting ring with magnetic mount. Neutrally buoyant machine includes internal counter-balancing, as well as overload sensors that sound alerts when users stress one of 6 axes. |
 Test System suits large scale, fibre-channel SANs.Agilent Technologies, Inc.
Santa Clara, CA 95051
Nov 14, 2002
Series 1730 includes Windows® 2000-based PC, 4-slot 2U chassis, and Fibre Channel Storage Area Network test cards. It enables Fibre Channel traffic generation at wire speeds of 1 or 2 Gbs, with allowances for any combination of data, error, link, fabric control, and fabric server traffic. Engineers can use test system's parametric control to set variables that simulate specific traffic conditions in target SAN under test.
|
 Parcel Shipping Scales interface with manifest software.Mettler Toledo, Inc.
Columbus, OH 43240
Nov 14, 2002 Suited for end-users with PC-based manifest software and shipping needs below 70 lbs, models PS15 and PS30 are National Type Evaluation Program (NTEP)-certified. Offered with GEOCALâ„¢ calibration, both models provide simple display and keyboard to eliminate operator confusion. They include 120 Vac, 9 Vdc wall mount power supply and 6 ft RS-232 serial interface cable to send commercial package weights electronically to controlling PC-manifest software. |
 Alarm Clock shows time, date, temperature, and humidity.Extech Instruments Corp.
Nashua, NH 03063
Nov 14, 2002
Hygro-Thermometer Alarm Clock measures relative humidity from 20-90% with ±5% accuracy. Temperature measurements are °C/°F selectable and range from 14 to 140°F with 2°F accuracy. LCD displays temperature and humidity readings as well as day, date, and month. Clock alarm, with 4 minute snooze function, is also included. Unit, with stand, measures 9.8 x 7.5 x 1 in.
|
 Thermowell withstands oxidizing environments to 3600°F.Nanmac Corp.
Framingham, MA 01702 2469
Nov 14, 2002 Model NC15 has high-temperature ceramic sheath with thermal shock resistance and high-strength properties at elevated temperatures. Stainless steel support tube protects ceramic sheath from breakage while using adjustable mounting adapter. Thermocouple calibration types include C, B, R, S, and K with lengths up to 48 in. Unit has closed hot end and is gas tight. Applications include furnaces, power generating plants, gas-fired ovens, and combustion chambers. |
 Resistance Thermometer meets ITS-90 ratio requirements.Hart Scientific, Inc.
American Fork, UT 84003 9775
Nov 14, 2002 Model 5698 Working Standard Platinum Resistance Thermometer features strain-free 25 ohm pure platinum sensor. Enclosed in 19 in. quartz glass sheath, unit covers temperatures from -200 to +661°C. Long-term drift is specified at ±0.006°C after 100 hr at maximum temperature. Calibration options include both fixed-point and comparison calibrations. |
 Bench-Top Dynamometer offers plug and play functionality.Sensor Developments, Inc.
Orion, MI 48359
Nov 14, 2002
Multi-function instrument includes rotating torque sensor with integrated optical encoder for reading out torque, speed, and horsepower. AutoID enables PTI to detect sensor and encoder calibration, units, and ppr for set-up of torque and horsepower testing. PTI single-button instrument offers capacities from in.-oz to thousands of ft-lb. Unit can also detect and hold peak torque/hp values, as well as display peak values and rpm at which they occurred.
|
Power Quality Analyzer suits indoor/outdoor applications.Summit Technology Inc.
Walnut Creek, CA 94546
Nov 14, 2002 Model PS4000 simultaneously performs swell, sag, transient, harmonic, and consumption functions. It also determines and holds transient information down to 10 microseconds and analyzes harmonic information to 63rd on every cycle. Displaying measurements continuously, unit interfaces via complete keypad. Capable of operating for 8–10 hours from rechargeable batteries, accessories allow direct connections to voltages from 1–15,000 V and currents from 10 mA to 6,000 A. |
Oscilloscopes and Probes validate high-speed digital designs.Agilent Technologies, Inc.
Santa Clara, CA 95051
Nov 14, 2002
Infiniium 54854A and 54855A are 4 and 6 GHz oscilloscopes that provide sample rate of 20 GSa/s on all 4 input channels simultaneously. They can also capture 4, full-bandwidth, real-time signals off single trigger event. InfiniiMax 1130A series active probes offer single-ended and differential measurements up to 7 GHz. Design allows use in difficult to reach situations such as probing between memory modules on server motherboards.
|
 Water Vapor Permeability Tester assesses barrier properties.PBI-Dansensor America Inc.
Glen Rock, NJ 07452
Nov 13, 2002 Lyssy L80-5000 performs barrier testing for high or low permeability in sensitive product packages. Unit measures barrier packaging material applications including films, foil, metallized foils, blister packaging, silicone oxygen substrates, surgical and hygienic membranes, and non-woven materials. It measures water vapor transmission ranges from 0.001 to 10,000 gr/m²-day. Unit can be moved to different locations and requires one annual calibration. |
 Digital Panel Meter delivers modular flexibility.Selco Products Co.
Reno, NV 89521-5908
Nov 13, 2002
Model A5000 1/8 DIN size meter uses interchangeable PC boards to provide selection of 7 output choices and 18 input choices. Unit is offered with or without display of setpoints. Output choices include none, HI & LO setpoint with 8 A relays, analog signal, RS-232C and RS-485. Input choices include DC voltage, DC current, AC current, AC voltage, resistance, temperature, frequency, strain and process measurement.
|
 Floor Scales can be used as computer peripherals.Arlyn Scales
East Rockaway, NY 11518
Nov 13, 2002 Series 5200 handles heavy loads starting at weight capacities of 2,500 lbs. With optional USB interface, scales can download information directly to Windows-based database program, allowing user to track, store, and manipulate weighing data in database or spreadsheet format. Units include stainless steel load cells, LCD indicator with 1 in. high digits, pushbutton tare, and units conversion. Readability is as low as 0.5 lbs. |
 Optical Micrometer uses built-in CMOS camera.Keyence Corporation of America
Elmwood Park, NJ 07407
Nov 13, 2002
LS-7030M Optical Micrometer makes high-speed measurements of fast moving targets on production and assembly lines via high-intensity, low-noise GaN LED light source. It generates continuous 30 mm wide beam with no gaps in detection due to scanning. CMOS camera in receiver head of Optical Micrometer provides image of target on Controller Monitor. Unit provides 2400 samples/sec, display resolution of 0.01 microns and repeatability of 0.15 microns.
|
 Pressure Transmitter measures low pressure.Sensortechnics Inc.
Dublin, CA 94568
Nov 13, 2002 Series CTU7000 offers long-term stability in pressure ranges from 0–0.15 to 0–100 psi. Unit has 0.86 in. diameter stainless steel housing and utilizes piezoresistive silicon pressure sensor. Output signals include 0.5–4.5 V, 4–20 mA, 1–6 V, and 0–5 V, with typical linearity of 0.2%. Transmitter is used for non-corrosive air and dry gases in applications including filter-monitoring, blow molding machines, and airflow measurement. |
 Linear Device Tester tests op amps and comparators.ProductionLine Testers
Pleasanton, CA 94588
Nov 13, 2002 Model IC443 bench top, integrated-circuit test system interfaces directly with handlers and probers for wafer probing or final assembly testing. Specifications are input into Excel-like spreadsheet, and test is compiled. Unit includes slew rate window comparator, sine wave generator, and 16-bit setting and measurement accuracy. Each analog pin has precision 4-quadrant VI-source with programmable compliances. Footprint measures only 24 x 22 x 20 in. |
(Showing headlines 13961 - 13980) << 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759
|
|
|