 Pressure Gage has stainless steel diaphragm seal.Dwyer Instruments, Inc.
Michigan City, IN 46361
Apr 29, 2003
Series 7000B Spirahelic® Pressure Gage with Diaphragm Seal employs all 316 stainless steel wetted parts for corrosive media service. Manufactured for severe service applications, product is suited for systems with high cycle rates, environments with continuous vibration or shock, and processes with problematic pressure surges and spikes. Unit includes all benefits of standard Spirahelic® Pressure Gage, is maintenance free, and requires no recalibration.
|
 Flowmeter measures open channels and part-filled pipes.TTI, Inc.
Williston, VT 05495
Apr 29, 2003 Mainstream Portable ultrasonic area-velocity flowmeter, suited for use in harsh field conditions, has high-impact case that is fully submersible and resistant to chemicals. Product works in liquids from clean water to raw sewage and measures flow velocities (bi-directional) from 0.03–16 ft/s with no zero offset or drift. Recording intervals are configurable from 30 sec to 60 min, while integrated data logger stores up to 250,000 measurements. |
Indicator/Conditioner offers auto setup for 25 load cells.Electro Standards Laboratories
Cranston, RI 02921
Apr 29, 2003 Model 4215 Smart Load Cell Indicator/Conditioner measures and controls strain-gage transducer based systems. It combines force channels, encoder position channels, print capabilities and RS232/485 serial communications. Microprocessor-based unit features ±999,999 display range, 24-bit resolution, and 0.005% nonlinearity. It includes 2-line vacuum fluorescent display, auto load cell identification, and front panel shunt calibration with 2 selectable resistors. |
 DC/DC Converters offer low output noise to 5 mVpp.Beta Dyne Inc.
Bridgewater, MA 02324
Apr 28, 2003 Isolated, 15 W, DC/DC converters, offered in single- and dual-output models, incorporate 250 mV dropout linear regulators and control circuit that maintains min constant dropout voltage over line and load temperature and output adjust range. With efficiencies to 88%, units include 6-sided shielding, soft start, adjustable outputs, and short circuit and thermal protection. Also offered: 750 µA off state current, industry pinout, and dual output tracking linear regulator. |
 RTD Input Signal Conditioner is field-configurable.Eurotherm Controls
Leesburg, VA 20175
Apr 28, 2003 Action Pak® Model AP4151-2000 RTD temperature input 4-wire transmitter utilizes TouchCAL™ technology for electronic microprocessor stability. Socket-mount, AC-powered device can be configured with on-board DIP switches and accepts 3-wire platinum, copper, and nickel RTDs. Inputs can be set for specific alpha curve, while output can be linear to input temperature signal or set for no linearization. Outputs are configurable for 0–5 or 0–10 Vdc or 0–20 or 4–20 mA. |
 Digital Portioning Scale is suited for remote applications.Rice Lake Weighing Systems
Rice Lake, WI 54868
Apr 25, 2003 Suited for fast-paced portioning and weighing, iPC compact, portable scale offers 500 hours of battery life. General-purpose scale provides 4-button operation and visible weight read-outs attainable with optional dual display. Offered with stainless steel platter and AC adapter, ergonomic design incorporates hardened plastic enclosure that withstands repetitive use in tough environments. |
 Scale Indicator/Controller offers configurable display.Rice Lake Weighing Systems
Rice Lake, WI 54868
Apr 25, 2003 Model 920i incorporates configurable LCD screen and modular design that provides open connectivity with Allen-Bradley Remote I/O and DeviceNet™, Profibus DP®, and Ethernet systems. Unit allows up to 4 scale displays with legal-for-trade information or up to 32 weight-only displays. Truck in/out program stores up to 1,000 ID numbers. Offerings include selectable A/D rates up to 960/sec, 100 setpoints, up to 340 digital I/O, 32 serial ports, 14 analog outputs, and 14 pulse inputs. |
 Truck Scale for above-ground or pit applications.Rice Lake Weighing Systems
Rice Lake, WI 54868
Apr 25, 2003 SURVIVOR® OTR low-profile, mid-duty truck scale offers 90,000 lb concentrated load capacity and G-Force™ load cell suspension design that ensures legal-for-trade accuracy. Self-checking mounting system uses 100% of gravity force from loading action against itself, instantaneously returning scale to dead center without check rods or bumper bolts. Steel deck model is constructed with 12 in. main beams and additional heavy-duty support beams under treadplate deck. |
 Thermo-Anemometer withstands air speeds to 90 mph.Extech Instruments Corp.
Nashua, NH 03063
Apr 25, 2003
Model 407113 displays air volume in CFM or CMM units and air velocity in 100-7880 fpm, 101-89.4 mph, 1.0-78.1 knots, 0.5-40.0 m/sec, and 1.8-144.0 km/hr. Temperature measurements range from 32.0-175°F with 1.5°F accuracy. Large 9999 count LCD simultaneoulsly displays Air Flow and Temperature or Air Velocity and Temperature. Air flow is displayed as instantaneous value, up to 20 point average or 2/3 flow value. Unit includes Data Hold, Auto Shut Off, and RS232 PC serial interface.
|
 PCI Mezzanine Card is suited for caution/warning systems.Thales Computers Corp.
Raleigh, NC 27610
Apr 24, 2003 PMC-PIO provides 64 channels of 3.3 V parallel I/O, each of which is independently programmable as input or output channel. Bi-directional I/O signals are TTL- and CMOS-compatible and voltage-protected. Unit interfaces to 33 MHz, 32-bit PCI bus through P1 and P2 connectors and enables 16 bits of I/O, configured as input, to be used to generate interrupt on change of state. Product is offered in 3 environmental versions. |
FT-NIR Analyzer provides continuous process monitoring.Thermo Electron Corp.
Waltham, MA 02454-9046
Apr 24, 2003 Nicolet® Antaris® FT-Near Infrared Multiplexer System allows user to remotely monitor up to 12 sample points throughout facility without labor associated with traditional sampling methods. Sample types include solids, powders, and liquids. Wide range of diffuse reflection, transflection, and transmission sample interfaces are available for almost any sample process. |
Spectrometer suits petrochemical industry.Thermo Electron Corp.
Waltham, MA 02454-9046
Apr 24, 2003 ARL OPTIM'X utilizes power of Wavelength Dispersive XRF technique. It features closely coupled optics and complete interception of primary X-ray beam from tube. Manual or automatic sample loader handles solids, liquids, or loose powders. SmartGonio™ optically-driven goniometer provides mutually independent rotation of crystal and detector. ARL OPTIM'X can provide sulfur analysis and measure Pb content in gasoline according to ISO or ASTM standards. |
Spectrometer suits metals analysis.Thermo Electron Corp.
Waltham, MA 02454-9046
Apr 24, 2003 Pre-calibrated ARL QUANTRIS, an Arc/Spark Optical Emission Spectrometer, is a second-generation CCD-based system that offers analytical performance at level of PMT spectrometers. Construction and vacuum environment provides for analytical stability, while software is provided for rapid commissioning and ease of use. Unit also offers flexibility for changing analytical requirements without need for mechanical re-builds. |
Data Acquisition System features modular, networked architecture.Yokogawa Corp. Of America
Newnan, GA 30265 1040
Apr 24, 2003 Model MX100 DAQMaster supports up to 1200 distributed universal channels from single PC. It offers true differential inputs through every universal input module. Main module serves as data acquisition engine and LAN connectivity, and can manage 1-6 measurement modules on MX100 backplane. CompactFlash memory ensures automatic and continuous data backup in case of network or PC failure. System is suitable for desktop or DIN rail rack mount use. |
 Power Meter displays multiple values simultaneously.Square D Co.
Raleigh, NC 27611
Apr 23, 2003
POWERLOGIC® Power Meter 800 allows user to view current or voltage of all 3 phases, plus neutral at one time. Logging functions capture power equipment data using 80-800 k memory. Combining data collection capabilities with firmware, PM800 can automatically forecast power usage. Users can access information such as real time trend plots, averages, and demand metering so that power control, load curtailments, and load preservation programs can be developed.
|
 Encoder System suits portable, electronic devices.Canon U.S.A. Inc.
Lake Success, NY 11042-1113
Apr 23, 2003 Model KP-1SM100 is based on laser rotary encoder technology. It obtains significant temperature characteristics by employing digital servo controllers and encoders with diffraction interference systems that utilize diffraction of laser beams. Scanning angle is ±10° and rotor inertia is 10.5 gcm-sq with 30 mm diameter mirror, resulting in positioning resolution of .02 arc sec. System can be used in miniaturized, high density PC board manufacturing. |
 PC/104-Plus Module supports CardBus and PCMCIA cards.WinSystems, Inc.
Arlington, TX 76011
Apr 21, 2003 PPM-Cardbus embeds PC card wireless and networking technology and supports 802.11 a/b/g, IEEE-1394 Firewire, USB 2.0, SCSI, and high-speed Ethernet for mobile computing functions. Module is based on Texas Instruments TI1510 PCI-to-CardBus controller, which is wired to PC/104-Plus bus. It supports 32-bit PC cards at bus speeds up to 33 MHz and is compatible with 16-bit PC cards. Module contains onboard 3.3 V linear regulator that supplies up to 1 A at card socket. |
 Flowmeter is used with hot oil circulating loops.Burger Engineering, Inc.
Olathe, KS 66061 5882
Apr 21, 2003 Positive displacement type flowmeter provides visual indication of flow rate from 5–40 gpm with accuracy of ±10% FS. Suited for use in applications where process temperatures reach 550°F, unit has max operating pressure of 150 psi and is equipped with 1 in. NPT(F) connections on each end of meter. Line-mounted product is housed in carbon steel. Flow rate is read by noting location of indicator ball as it corresponds to scale etched into front cover. |
 Meter displays current and volts in AC line applications.Avatar Engineering Corporation
Danvers, MA 01923
Apr 21, 2003
MiniMeter Model LM15 features integral display and current transformer housed in water-clear polycarbonate shell less than 1 in. square. It provides display of AC load currents up to 15 A for 50 or 60 Hz service. Display is self-powered so no additional or external components are required. Electrical connections are made by quick-connect blade terminals, and panel mounting uses single brass spring retainer with anti-slip feature for secure mounting.
|
 Weighing Indicator has 5 point comparator function.A & D Weighing
Milpitas, CA 95035
Apr 21, 2003
AD-4406 portable indicator for platform or truck scales uses 6 "C" batteries for up to 180 hr of operation. Optional rechargeable battery pack or AC adapter is available. With RS-232C and programmable printer format function, users can customize print protocol and output of RS-232C data. With resolutions of 40,000 counts and A/D conversion rate of 10 times/sec, device includes digital linearization function and can drive up to four 350-ohm load cells.
|
(Showing headlines 13401 - 13420) << 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756
|
|
|