ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
IMT Career Journal
IMT Fluid & Gas Flow Journal
IMT Green & Clean Journal
IMT Machining Journal
IMT Procurement Journal
 Industry News
Latest New Product News
Association & Government News
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
FABTECH
Society of Manufacturing Engineers
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Test & Measuring Instruments




(Showing headlines 13201 - 13220)   << 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 ...

Saturation System provides tube and pipe inspection.

Zetec, Inc.    Issaquah, WA 98027 0140
Jul 03, 2003 When combined with MIZ-27CT Component Test Instrument and Z100 Probe, SU-100 Magnetic Saturation System can detect through-wall defects to 0.028 in. Air-cooled system allows integration into existing manufacturing lines. Saturation System and Z100 Dual Differential Encircling Probe accommodate tubes and pipes from 10–100 mm diameter OD. Driven by multi-frequency, multichannel, MIZ-27CT eddy current tester, Z100's outer coils detect gradual flaws, laminations, and wall thinning.

Data Loggers suit energy and HVAC applications.

Data Loggers suit energy and HVAC applications.

Onset Computer Corp.    Bourne, MA 02532
Jul 02, 2003 Able to store 65,291, 8-bit resolution measurements, HOBO® Pro Series weatherproof data loggers measure and record indoor and outdoor climate data. Portable monitoring devices withstand harsh indoor environments as well as condensing outdoor conditions. Products are offered in 3 models: single-channel temperature, 2-channel temperature and RH, and 2-channel temperature. Units provide ±0.5°F accuracy and ±3% RH accuracy with 12-bit resolution.

Impact Tester is used with plastics, PVC, and vinyl siding.

Impact Tester is used with plastics, PVC, and vinyl siding.

BYK Gardner USA    Columbia, MD 21046 2729
Jul 02, 2003 Automatic lift Gardner impact tester offers alternative to standard manual Gardner impact tester. It reduces operator arm and finger stress, while spring-loaded impact weight-positioning device eliminates operator variances in test repeatability results. Product operates on compressed air and has no electrical connections. Plastic guard protects operator against sample shattering, and 2-button system activates lift.

Torquemeter responds to dynamic and static inputs.

Torquemeter responds to dynamic and static inputs.

Himmelstein, S., & Co.    Hoffman Estates, IL 60195
Jul 02, 2003 Mounted between NEMA C-Face motor and its load, hollow reaction CF2700 Series senses motor or load torque. Suited for industrial measurement and control applications, series offers 0.1% accuracy, has no bearings or rotating parts, and require no maintenance. Series handles 500% overloads and is offered in 2 types: one outputs 0 to ±10 V, while the other 2-wire transmitter outputs 4–20 mA. Measurement bandwidth is DC to 1,000 Hz.

Top Loading Balances provide measurements in less than 1 sec.

Top Loading Balances provide measurements in less than 1 sec.

Shimadzu Scientific Instruments, Inc.    Columbia, MD 21046
Jul 02, 2003 Series UW/UX utilizes UniBloc mechanism, which provides quick response and stability against environmental changes. Windows®Direct communication function requires no software installation to integrate balances with existing lab or business software. Balances provide specific gravity measurement, piece counting, and check weighing. Data capture function sends weighing data and GLP, GMP, and ISO compliant calibration reports to printers or computers.

Trace Analyzer is based on Cavity Ring-Down Spectroscopy.

Trace Analyzer is based on Cavity Ring-Down Spectroscopy.

Tiger Optics, L.L.C.    Warrington, PA 18976-2426
Jul 01, 2003 LaserTrace™ modular, multi-point, multi-species analyzer detects molecular contaminant down to parts-per-trillion levels. It can detect H2O, O2, CH4, H2, CO, NH4, H2S, and HF in range of 100 ppt to 1000 ppm. Using fiber optic connections, unit affords remote monitoring of up to 4 different analytes at 4 sample points for as many as 4 different gases. It is calibration-free and transportable.

Handheld Temperature Calibrators offer full-size performance.

Handheld Temperature Calibrators offer full-size performance.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Jul 01, 2003 JOFRA™ ETC dry-block calibrators feature one-key-one function technology, multiple bore blocks for meeting range of applications, programmable test setup, and RS232 communications and software. Model ETC 125A ranges from 14–257°F and is stable to ±0.09°F, while Model ETC 400A ranges from 82–752°F and is stable to ±0.27°F. Both units heat up as quickly as 212°F per minute and offer accuracy of ±0.9°F.

PC/104 Card is Navigator®-based.

PC/104 Card is Navigator®-based.

Performance Motion Devices, Inc.    Lexington, MA 02421
Jul 01, 2003 Navigator®-PC/104, offered in 1–, 2-, and 4-axis versions, is suited for DC brushed, brushless DC, and step motors. Designed in surface mount CMOS technology, product provides dedicated motion control features such as trajectory generation, servo loop closure, quadrature signal input, motor output signal generation, trace, and on-the-fly changes. Unit offers servo loop rate of 100 µsec/axis with 5.0 Mcount/sec quadrature encoder input rate.

DAQ System is ASTM E139 compliant.

DAQ System is ASTM E139 compliant.

MAS Associates, Inc.    Queensbury, NY 12804
Jul 01, 2003 Creep and Rupture data acquisition system captures deformation as factor of time (creep test) and measurement of time for fracture (rupture test). Multiple stations are monitored by PC to develop historical database and record % strain and temperature concurrently for each station. Data points are logged to database at select intervals and displayed on PC in graph form. Data only logged when necessary and zipped into reduced file for efficiency.

Pressure Transmitter features base accuracy of 0.075%.

Pressure Transmitter features base accuracy of 0.075%.

ABB Instrumentation    Warminster, PA 18974
Jul 01, 2003 Model 2600T Safety Pressure Transmitter is compliant with Safety Integrity Levels SIL 2 and SIL 3. It includes self-diagnostics, signal validation of both sensor and electronics, and hardware/software redundancy. Two pressure signals from device are independently detected and analyzed internally. Microcontroller compares signals to validate output pressure signal, and transmitter’s analog output is driven upscale or down to safe condition if difference is detected.

Laser Particle Counter features color touch-screen display.

Laser Particle Counter features color touch-screen display.

Lighthouse Worldwide Solutions    Medford, OR 97501
Jul 01, 2003 SOLAIR 5100+ portable counter offers sensitivity of 0.5 micron and flow rate of 1.0 cfm with dynamic range up to 25.0 microns. It can store particle count data for 6 particle size channels and data from up to 4 environmental sensors. All data can be downloaded to computer or printed to built-in thermal printer. Sample output is internally filtered to HEPA standards. Unit runs on removable Li-Ion battery or standard AC power.

Particle Counter has dynamic range of 0.3–10.0 µm.

Particle Counter has dynamic range of 0.3–10.0 µm.

Lighthouse Worldwide Solutions    Medford, OR 97501
Jul 01, 2003 SOLAIR 3100+ stores particle count data for 6 particle size channels as well as data from up to 4 environmental sensors. Data can be downloaded to computer or printed to built-in thermal printer. Portable counter offers 0.3 micron sensitivity at 1.0 cfm flow rate and has 5.7 in. color touch-screen display. Product utilizes optical particle counting technology and has stainless steel enclosure that houses 32-port universal manifold.

Optical Measurement System is fully automatic.

Optical Measurement System is fully automatic.

RAM Optical Instrumentation, Inc.    Tempe, AZ 85281-7215
Jul 01, 2003 Onyx(TM) dimensional measurement system provides video measurement with 9 x 9 x 6 in. XYZ travel range and incorporates bridge-column design, ˝ micron linear scales, and servo-driven stages. Optical system combines flat field parfocal zoom optics with color video camera, while imaging system has Charged-Couple Device technology. Powered by QVI electronics with DSP technology, unit utilizes Basic-X Measurement Software with point-and-click interface.

Charged-Plate Monitor automates data collection.

Charged-Plate Monitor automates data collection.

Trek, Inc.    Medina, NY 14103 0728
Jun 30, 2003 Model 157 combines precision charge measurement capability with one USB serial interface to allow user to control unit from computer. With TREK software, operators can program test sequences and download test results, allowing quantitative tests to be repeated, analyzed, programmed, saved, and retrieved. Unit provides virtually infinite impedance loading of ion collecting plate, while allowing plate to be charged and monitored through same cable connection.

Serial I/O Card boasts top speed of 921.6 Kbps.

Serial I/O Card boasts top speed of 921.6 Kbps.

Sealevel Systems Inc.    Liberty, SC 29657
Jun 30, 2003 Model C4-104.ULTRA multi-interface, PC/104 serial I/O card allows user to select desired interface via software. RS-232, RS-422, or RS-485 modes may be selected independently for each of 4 ports. Board uses XR16C864 UART, which provides 128-byte FIFO. In RS-485 mode, C4-104.ULTRA offers automatic control of RS-485 driver enable for trouble-free network master arbitration. RS-485 network termination can be selectively added to circuit via software command.

Microscope has 1 in. reticle for close examinations.

Microscope has 1 in. reticle for close examinations.

Scientifics, A Division of Edmund Scientific    Tonawanda, NY 14150-6711
Jun 27, 2003 With 50X magnification, direct measurement microscope is suited for detecting flaws or imperfections, making surface measurements, or examining fibers or print. Characteristics include 3 mm field of view, 20 mm working distance, and 5/16 in. eye lens diameter. Optical clear plastic base model converts to freestanding microscope that can be focused and locked. Able to fit in pockets, unit measures 4Ľ in. high without base and 4˝ in. with base.

Analog-To-Digital Converter digitizes high-frequency signals.

Analog-To-Digital Converter digitizes high-frequency signals.

Linear Technology Corp.    Milpitas, CA 95035
Jun 27, 2003 Model LTC1748 80 Msps, 14-bit converter offers 76.3 dB signal to noise ratio and 90 dB spurious free dynamic range for high speed applications. Undersampling 70 MHz input, unit delivers 75.4 dB SNR and 80 dB SFDR. Sample and hold bandwidth of 250 MHz allows for undersampling of input frequencies in excess of 70 MHz. Input can span ±1 V to ±1.6 V to optimize dynamic performance. Separate digital output supply pin is provided for connections to low voltage DSPs and FIFOs.

Trace Gas Leak Detector has ultra-high sensitivity.

Trace Gas Leak Detector has ultra-high sensitivity.

Uson L.P.    Houston, TX 77041
Jun 26, 2003 Portable Qualichek 200 utilizes pressurized trace gas technique and Electron Capture detection system to locate and quantify leaks in various applications. It displays leak rate or concentration. Factory calibrated for SF6, unit has 0–2 V analog output, RS232 serial printer interface, memory for storage of up to 100 results, and built-in fault diagnosis. Unit may be calibrated by user and includes user-adjustable audible alarm level.

Macroscope suits forensic comparison applications.

Macroscope suits forensic comparison applications.

Leica Microsystems, Inc.    Buffalo Grove, IL 60089
Jun 26, 2003 Model FS C integrates tilting binocular tube to accommodate examiners of all statures. Automation and motorization allow synchronous control of both stages, as well as remote positioning of stage and focus controls. Macroscope enables side-by-side or superimposed image comparison. Built-in 5x magnification changer expands magnification range from 4-60x and provides up to 8 discrete magnification settings. Apochromatically-corrected objectives provide high-contrast images.

Digital Oscilloscope Workstation includes Windows 2000 PC.

Digital Oscilloscope Workstation includes Windows 2000 PC.

Nicolet Biomedical, Inc.    Madison, WI 53711 4495
Jun 26, 2003 Sigma Series offers signal acquisition, analysis capabilities, and connectivity in one portable workstation. Offered with real-time measurement capabilities, users may also load third party analysis directly on unit. Offerings include up to 8 input channels, memory lengths to 4 million samples, and 10.4 in. touch-screen display. Product is available in 12-bit (Sigma 30), 8-bit (Sigma 60), and mixed mode (Sigma 90) versions.




(Showing headlines 13201 - 13220)   << 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy