|
|
|
|
|
Test & Measuring Instruments
(Showing headlines 12581 - 12600) << 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 ...
|
 Diode Laser Spectrometer measures directly in hot flue gases.Siemens Energy & Automation Inc., Motors & Drives Div.
Alpharetta, GA 30005
Mar 16, 2004 Model LDS 6 provides continuous in-situ measurement of gas concentrations with reaction time in seconds range. It is equipped with fiber-optic sensors and maintenance-free reference cell for self-calibration. Integral communications interface permits remote scanning of measured values to set spectrometer parameters and carry out diagnostics. Unit is suited for applications involving changing gas compositions, high process temperatures, and varying concentrations of particles. |
 Frequency Converter offers integrated safety mechanisms.Siemens Energy & Automation Inc., Motors & Drives Div.
Alpharetta, GA 30005
Mar 16, 2004 Comprised of distributed intelligence, I/O, motor starter, and safety system, Model ET 200S-FC controls speed of asynchronous motors steplessly. Hot-swappable modular unit includes line-commutated regenerative feedback, closed-loop control section, and power section with rated output from 0.75–4 kW. Safe Stop function prevents unintentional starting of drive, while Safe Braking Ramp monitors standstill, and Safe Reduced Speed prevents speed limit from being exceeded. |
 I/O Module and Safety Monitor suit Category 4 operation.Siemens Energy & Automation Inc., Motors & Drives Div.
Alpharetta, GA 30005
Mar 16, 2004 Flexible I/O module S22.5F and safety monitor unify safety and standard technology on AS-interface bus. S22.5F, with IP20 degree protection, has 2 inputs that enable safe link to signals in control cabinet. Safety monitor offers integrated on- and off-delays as well as pulse functions. Momentary shutdowns are saved in buffer memory, logical functions can be linked with each other and cascaded, and safety-related components can be configured virtually. |
 Flare Flowmeter validates calibration while installed.Fluid Components Intl.
San Marcos, CA 92069 5115
Mar 16, 2004 Model GF03 utilizes VeriCalâ„¢ in-situ calibration verification kit to meet environmental agency regulations that require installed calibration checks of flow instrumentation used in flare gas systems. It meets specifications for +5% accuracy, repeatability of +0.5% of reading and flow range from 0.50–275 sfps. Operating in temperatures from -40 to 350°F and pressures to 100 psig, sensor is effective for reading and reporting low and high flow rates. |
 Optical Encoders offer plug and play installation.BEI - Duncan Electronics
Irvine, CA 92618
Mar 16, 2004
Series 920 miniature, incremental encoders are capable of accepting disc radii as small as 9.78 mm with resolutions to 2,450 ppr. Featuring 5-pin mating connector that mates with AMPHEONOL and MOLEX configurations, units measure 1.25 x 1.05 x 0.39 in. including caliper, connector, and PCB board. Opto-ASIC design includes phased array photo diode IC noted for ±0.010 in. tolerance to axial movement and 50 mA power consumption.
|
 Distance Measuring System has 20 cm to 170 m range.Leuze electronic, Inc.
New Hudson, MI 48165
Mar 16, 2004
Model OMS 2 Laser Optical Distance Measuring System incorporates signal processors coupled with laser technology to allow values of measured distances to be calculated within milliseconds. Data communication between position controller/PLC and unit takes place via SSI, Profibus, Interbus, deviceNet, CANopener, or RS 422/485 interfaces. With IP65 protection rating, construction includes metal housing and glass optics.
|
 Power Monitors measure multiple 3-phase parameters.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Mar 15, 2004 Model WM12 multi-function, 3-phase power monitors are available in 96 mm² panel mount ¼ DIN housing with 46 mm behind panel depth, or with DIN rail mounting style for mounting within electrical enclosures. They monitor electrical parameters for 3-phase, including power factor, frequency, demand, and reactive energy. Both styles are available with communication functions that utilize Modbus®-RTU protocol for monitoring up to 255 individual instruments. |
 Analyzer tests all functions of external pacemakers.Netech Corp.
Hicksville, NY 11801-1502
Mar 12, 2004 Featuring menu-driven operation with 8 tactile keys and 4-line LCD display, portable EXPMT 2000 tests and verifies all functions of any external pacemaker. ECG snaps (5) are standard along with RS 232 serial port, which allows for printing heading and test measurements on separate printer. Information can also be sent to Palm Pilot. For use with transcutaneous pacers, External Test Load has 12 user-selectable loads from 100–1,000 ohms. |
 Analyzer tests defibrillators and pacemakers.Netech Corp.
Hicksville, NY 11801-1502
Mar 12, 2004 Delta 3000A analyzes defibrillators with monophasic or bi-phasic waveforms and all AEDs. With 12 built-in user-selectable test loads, unit can also test transcutaneous pacemakers. ECG simulator provides 12 arrhythmias plus sine, square, and triangle performance waveforms. Operation is via menus and 8 tactile feel keys. Instructions and measurements are displayed on 4-line, LCD display, while print key ouputs test measurements to RS-232 serial port.
|
 Micro Manometer targets HVAC industry.E Instruments International LLC
Langhorne, PA 19047
Mar 12, 2004
Portable, hand-held, Mini Pressure Pro Model MP50 measures positive, negative, and differential pressure with accuracy of ±2.5% of reading and 0.1 in. H2O resolution. Unit provides measurements in mmH2O, kPa, inWg, mbar, and mmHg. It records minimuum and maximum values and can display 2 parameters simultaneously. Protective rubber boot is available on request.
|
 Motor Fixture accommodates 6 in. dia. motors.Magtrol, Inc.
Buffalo, NY 14224-1322
Mar 12, 2004
Adjustable Motor Fixture locates and holds motor in place for running any test, while maintaining center height required for coupling to company's HD-106 through HD-715 Hysteresis Short Base Plate Dynamometer. Lead screw adjustment provides centering for motor while T-Slot Base supplies multiple position options for various motor lengths. Adjustable bridge provides clamping anywhere along axis of motor and thumbscrew protects against vibration.
|
 Pressure Transmitter provides 0.25% FS accuracy.Dwyer Instruments, Inc.
Michigan City, IN 46361
Mar 12, 2004
Series 626 Industrial Pressure Transmitter contains pressure sensor that offers 0.25% FS accuracy on ranges from 15-500 psig. Product senses pressure of air and compatible gases and liquids, then sends 4-20 mA output signal. Enclosed within NEMA 4X housing, it withstands temperatures to 200°F. Wetted parts of 316 and 316L stainless steel permit use in various applications.
|
 Differential Pressure Gauge is diaphragm-operated.Mid-West Instrument
Sterling Heights, MI 48314
Mar 12, 2004 Model 142 utilizes diaphragm to provide complete high side to low side isolation. It extends differential pressure down to 0–20 in. H2O with accuracy below 0–400 in. H2O. Maximum range is 0–25 psid. Unit features full over range protection in both directions up to rated safe working pressure of 3,000 psi for aluminum and stainless steel, and 1,500 psi for brass. Accuracy is ±3-2-2% of full scale. Dial sizes include 2½, 3½, and 4½ in. |
 Handheld Digital Manometer is suited for technicians.Dwyer Instruments, Inc.
Michigan City, IN 46361
Mar 12, 2004
Series 477A contains differential pressure sensor that offers 0.1% FS accuracy on air ranges from 20 in. w.c. to 100 psid. It offers selectable engineering units, audible and visual overpressure alarms, and auto-zero function. With storage capacity for up to 20 readings, backlit unit is suited for maintenance personnel or technicians who require accurate standard to check instrumentation or equipment as to ensure proper performance.
|
 Pressure Transducer suits submersible applications.Setra Systems, Inc.
Boxborough, MA 01719
Mar 12, 2004 With CVD strain-gauge design, Model 528 is resistant to aging and insensitive to thermal transients and pressure cycling. Modular design has various pressure fittings and electrical connections, and all wetted parts are constructed of corrosion-resistant 17-4 PH stainless steel. Product exhibits 0.1% FS accuracy over –20 to +212°F compensated temperature range and is offered with choice of output ranges. Pressure ranges are offered from –14.7 to 6,000 psi. |
 Sulfur Analyzer detects concentrations below 10 mg/kg.Oxford Instruments
Concord, MA 01742
Mar 12, 2004 With sulfur detection limit of less than 1 mg/kg, Twin-X ULS proportional counter EDXRF system meets criteria for measurement of sulfur below 10 mg/kg in road fuels. It incorporates low-background, proportional counter detector with integrated Focus 5 ULBD technology. Designed for sulfur determination in concentration ranges from 3–150 ppm and higher, instrument features menu-guided user interface and QC-check functionality for performance monitoring. |
 Canister Conditioning System provides emissions testing.Sakor Technologies, Inc.
Okemos, MI 48864
Mar 12, 2004 ECS 3000â„¢ Canister Conditioning System meets EPA/CARB requirements for emission canister conditioning using butane/nitrogen procedures. It can execute simultaneous and independent multiple-canister operations. Purge/load module incorporates 2 independent butane loading stations, and system control console can be remotely located. Unit is capable of configurable data and alarm logging, test report generation, and temperature and humidity monitoring. |
Interface Chip suits set-top boxes and IC card readers.STMicroelectronics
Lexington, MA 02421
Mar 12, 2004
Model ST8004, for asynchronous 3 and 5 V smart cards, meets ISO 7816-3 standard and is compatible with NDS conditional access system. Analog chip has 3 protected, half-duplex, bi-directional buffered I/O lines and performs all supply protection and control functions when placed between smart card and microcontroller. Interface includes supply supervisor to control transients, ESD protection on card side, and thermal and short-circuit protection on all card contacts.
|
Instrument quickly analyzes complex chemical compounds.Haber, Inc.
Arlington, MA 02474
Mar 12, 2004 Digital Electromolecular Propulsion Analytical Instrument, Model EMP 15 is rooted in electrochemical process that affects differential movement and analytical separation of molecules. EMP separations are typically completed in 1–3 min, with certain separations being completed in seconds. Refined EMP separations have extremely sharp zones with minimal band-broadening and diffusion aberrations. |
 Automatic Polarimeter has 30-measurement storage capacity.Paul N. Gardner Co., Inc.
Pompano Beach, FL 33060 6608
Mar 11, 2004
Compact AP-100 features automatic measurement and digital display of selectable measurement readings, which include Angle of Rotation, International Sugar Scale, Specific Optical Rotation, Concentration, and Purity. Operation requires user to place sample tube in unit and press start. Flash memory stores 30 most recent measurement readings, and out-of-range measurements are indicated instantly by graphic display. Polarimeter may be calibrated manually.
|
(Showing headlines 12581 - 12600) << 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760
|
|
|