Test & Measuring Instruments
(Showing headlines 12541 - 12560) << 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 ...
|
 Non-Contact Detector senses live AC source from 90–240 V.Lascar Electronics, Inc.
Palo Alto, CA 94303-0727
Mar 08, 2004 Pen-shaped, non-contact AC voltage detector, designed for ease of carrying and storage, has red LED and buzzer alarm that inform user when AC voltage is present. AC Voltage Stick pack includes 2 AAA batteries and precision screwdriver. |
LCR Meter measures 8 x 4 x 7 in. and weighs 5½ lb.TEGAM, Inc.
Geneva, OH 44041
Mar 08, 2004 Model 3525 general-purpose programmable LCR Meter suits impedance parameter testing. Flexible design allows testing of capacitors, inductors, coils, resistors, materials, thermoelectric cooling devices, and piezoelectric sensors. Accuracy of 0.08% and measurement speed of 15 mS is provided. It also features 99 storable panel settings, dual 4½ digit LED display, voltage and current monitors, and built-in comparator function. |
 PC/104 Interface Card withstands harsh environments.Softing North America, Inc.
Newburyport, MA 01950
Mar 05, 2004 Based on modular PC/104 standard, Model CAN-AC2-104/I offers two 9-pin connection ports, each connecting to interface card via ribbon cable. With 256 kbyte SRAM and 4 kbyte dual-port RAM, unit operates in environments with temperature range from –40 to +85°C and relative non-condensing humidity up to 90%. It is also available coated for protection against condensing moisture. Card supports Windows 95/98/ME/NT/XP, Windows CE .NET, and Linux. |
 Dual Roller Scale suits high-volume cargo operations.Weigh-Tronix, Inc.
Fairmont, MN 56031
Mar 05, 2004 Dual Roller Scale consists of 2 side-by-side, 100 x 65.5 in. roller platforms that incorporate total of eight 2,500 lb Weigh Bar® sensors, providing total capacity of 20,000 lb. Self-contained scale features 27 in. non-skid walkway between roller platforms, 4 in. diameter rollers rated to 650 lb, integrated side rails and swing-up stops to assist in load positioning, and stainless steel junction box with 25 ft of indicator cable. |
 Telecom Tester meets CORE environmental standards.Thermo Electron Corp.
Waltham, MA 02454-9046
Mar 04, 2004 KeyTek E518 module, for ECAT-based telecom test systems, offers capability of protection coordination testing to 2 kV. It produces 10/1000 µs waveforms to meet first and second level lightning test requirements. Peak voltage and current monitors provide readings from E518 to front panel or computer controller while supplying attenuated outputs to BNC connectors to verify generator waveforms. Additional telecom test modules, surge, and EFT modules are also available. |
 ORP and pH Sensors have differential design.Walchem Corp.
Holliston, MA 01746 1460
Mar 04, 2004 Constructed with glass electrode that is not prone to chemical attack, WDS Series differential pH and ORP sensors transmit signals up to 3,000 ft and are resistant to ground loop problems. Sensors can be replaced if reference solution becomes contaminated or salt bridge becomes clogged. Reference electrode is constructed from pH glass and is embedded in pH 7 buffer within sensor behind porous, replaceable salt bridge. |
 Mezzanine Card provides 16 analog channels.Men Micro Inc.
Lago Vista, TX 78645-4160
Mar 04, 2004
M-Module M35N can be configured with 16 single-ended, or 8 differential voltage or current analog channels, each with acquisition time of 5 µs with 14-bit resolution. Analog inputs are optically isolated from digital computer bus. M-Module is suited for open bus systems, such as those based on CompactPCI, PCI, PM, or VME. It can also be deployed in standalone, busless embedded computer systems. Extended temperature version operates over -40 to +85°C.
|
 Modules network-enable serial devices.Moxa Inc.
Brea, CA 92823
Mar 04, 2004
Measuring 57 x 40 mm, Series NE-4120S/A Network Enablers consume less than 1.5 W and integrate into serial devices to make them 10/100M Ethernet-ready. By network-enabling serial devices, card reader/SCADA systems and controllers can access and gather real-time data from NE-4120S/A modules. TCP/IP stack supports TCP Server, TCP Client, UDP, and Real COM operation modes. Configuration is done with Windows utility, Web browser, or serial console.
|
 IR Sensor Pair has variable distance sensing capability.Optek Technology, Inc.
Carrollton, TX 75006-6905
Mar 04, 2004
Optical emitter/phototransistor pair model OPB100 provides DC drive current and variable distance sensing up to 1 m. Suited for linear or vertical sensing applications, 890 nm input diode features forward DC current of 100 mA, with reverse DC voltages to 2.0 V and power dissipation of 142 mW. Output phototransistor features collector-emitter voltage of 30 V and emitter-collector voltage of 5 V. Collector DC current is 50 mA with 250 mW power dissipation.
|
 Vortex Flowmeters offer mass measurement of steam.Endress + Hauser Inc.
Greenwood, IN 46143
Mar 03, 2004 Utilizing Differential Switched Capacitor sensor technology, PROline® Prowirl 72/73 mass flowmeters are immune to vibrations up to 1 g, extreme temperature shocks, clogging, water hammer, and high pressure. They support superheated steam, compressed air, water, and gas measurement. Two-wire instruments require no additional power supply or wiring. Depending upon application, user can choose mounted or remote evaluation electronics.
|
 Glass Bottles are made of Type III soda-lime.Wheaton Science Products, Inc.
Millville, NJ 08332
Mar 03, 2004 Graduated in millimeters and ounces, Valumetricâ„¢ Bottles are not only suited for use as sample bottles, but also for dry powders, soil samples, and specimen storage. Caps are pre-attached, eliminating need to match caps with bottles in laboratory or storeroom. Convenience Packs include Hazard Communication Labels and Tamper Evidence Strips, allowing for content identification, and visible
evidence of integrity of samples in transit or long term storage. |
 Acid Dewpoint Monitor maximizes boiler efficiency.AMETEK Solidstate Controls
Columbus, OH 43085
Mar 03, 2004
Conserver IV - Model 440 determines acid dewpoint temperature in order to meet Clear Skies Initiative and reduce maintenance problems associated with SO3 in boiler operation. Unit offers 6 programs, each with custom display: SO3; SO3 calculation to indicate relationship to condensables; Minimum metal temperature calculation; SO3 calculation to indicate relationship to corrosion potential; efficiency calculation; and Rate of Acid Build Up graph.
|
 Rheometer incorporates yield stress capability.Brookfield Engineering Laboratories, Inc.
Middleboro, MA 02346
Mar 03, 2004 DV-III Ultra comes with spindles, Rheoloaderâ„¢ and EZ-Yieldâ„¢ software programs, power base, guard leg, and temperature probe. It delivers continuous sensing and display with ±1.0% accuracy and ±0.2% repeatability. In stand-alone mode, operator enters test parameters and temperature control requirements then starts program. Results are shown on built-in display. Unit provides built-in math models for data analysis and includes yield stress measurement capability. |
 Bimetal Thermometers can be read at any angle.Dresser Instrument
Stratford, CT 06614-5145
Mar 03, 2004 Bimetal Thermometers feature Maxivision® dial, which eliminates parallax error. They come in 2, 3, and 5 in. dial sizes and in Fahrenheight, Celsius, or dual scale ranges. Standard stem lengths range from 2½ through 24 in., while non-standard stem lengths up to 60 in. can be custom-made. Thermometers are offered with hermetically sealed cases and lower, rear, or every-angle connections. They are manufactured to ASME B40.3 Grade A accuracy of 1% of span. |
 Digital Refractometers offer ±0.1% and ±1 ppt accuracy.Kernco Instruments Co., Inc.
El Paso, TX 79927 7338
Mar 03, 2004 Series DR Refractometers read and measure salt/salinity from 0-28%, refractive index from 1.3330–1.3900 nD, and Brix from 0–35%. Units feature 0.75 in. digital LCD readout to eliminate misreadings. Microprocessor provides automatic calibration, automatic shutoff after 3 min, and low battery indicator. Water-resistant design protects electronics from wet environments. Suited for samples up to 100°C, models include stainless steel plate for optical sample prism. |
 Digital pH Meter covers 0-14 pH range.Kernco Instruments Co., Inc.
El Paso, TX 79927 7338
Mar 03, 2004 Hand-held, pH stick meter, Model 8514 features .375 in. LCD display with hold function to retain readings. Probe mounts directly into LCD meter to form single unit. Meter is supplied with epoxy combination electrode and slope control feature to compensate for aging of electrode. It offers ±0.01 pH readability and accuracy, with manual temperature compensation from 0–60°C. |
 Rheometer includes UV cure monitoring accessory.ATS RheoSystems
Bordentown, NJ 08505
Mar 03, 2004 STRESSTECH HR utilizes light triggering capability and Fast Oscillation Data Analysis, which allows for real-time UV cure profiling and shrinkage determination by providing ability to capture rapid, transient changes in material. Along with RheoExplorer v5 software, unit provides accurate measurements of DNS materials, which typically exhibit shrinkage of 10-15% while curing. Rheometer offers data collection rates greater than 100 points/s. |
Tester measures clamping force on paper rolls.Brudi Bolzoni Auramo
Homewood, IL 60430
Mar 03, 2004 Portable TEST PAD helps eliminate paper roll out-of-roundness by showing real clamping force value with same diameter as paper roll itself. Pad radius provides non-damaging measuring operation. LCD display is battery operated and requires no external power source. |
 Digital Multimeters are CAT III rated.Wavetek Meterman Test Tools
Everett, WA 98206-9090
Mar 02, 2004 Series XP Digital Multimeters feature VolTecâ„¢ non-contact voltage detectors, ergonomic 155 x 72 mm case, Magne-Gripâ„¢ holster, integrated tilt-out bail, and 9 V battery. Models 5XP and 15XP provide 1999-count display, 750 Vac/1000 Vdc, 200 mA ac/dc current, 20 megaOhm resistance, Data Hold with min/max, continuity beeper, and battery test. Model 35XP provides 4000-count display, 0.5% accuracy, built-in type K thermometer, and 0.1 µA resolution for flame detector troubleshooting. |
 Motion Feedback Encoders suit space-restricted designs.MicroE Systems
Bedford, MA 01730
Mar 02, 2004
Measuring 8.4 mm tall, Mercury(TM) miniature encoders are vented and compatible with 10-8 Torr vacuum levels. Programmable Model M3500 features resolution to 5 nm, RS-422 compatible quadrature output, plus alignment and setup using integral LED indicators. Model M1000V provides analog sine/cosine output for use with interpolation electronics. SmartSignal(TM) alignment tool is used for alignment and setup procedures.
|
(Showing headlines 12541 - 12560) << 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756
|
|
|