ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
IMT Career Journal
IMT Fluid & Gas Flow Journal
IMT Green & Clean Journal
IMT Machining Journal
IMT Procurement Journal
 Industry News
Latest New Product News
Association & Government News
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
FABTECH
Society of Manufacturing Engineers
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Test & Measuring Instruments




(Showing headlines 12461 - 12480)   << 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 ...
Spectrometers are designed for OEM applications.

Spectrometers are designed for OEM applications.

Headwall Photonics, Inc.    Fitchburg, MI 01420
Mar 17, 2004 Summit™ 6400 series configurable single-beam spectrometers feature 1 nm resolution from 190-400 nm. Units include holographic diffraction grating technology, 512-element silicon photodiode array detector, and low-noise 16 bit electronics. Scan rate is 4 spectra per second, aperture is f/2.5 with focal length of 100 mm. Applications include industrial process monitoring, medical diagnostics, high-throughput screening, and laboratory research.

Coriolis Transmitter features multivariable DSP technology.

Coriolis Transmitter features multivariable DSP technology.

Emerson Process Management Dieterich Standard Inc.    Boulder, CO 80301
Mar 17, 2004 Requiring only 0.03 cu-ft of control room space, Micro Motion® Model 1500 MVD™ Transmitter provides 4-wire connection to sensor for power and signal. It delivers mA and frequency outputs for direct mass and volumetric flow measurement, and allows monitoring of density, temperature, flow totals, and meter diagnostics. Online monitoring and diagnostics data delivered by transmitter provides predictive process and flow meter health information.

Multiplexer provides 32 single channels.

Multiplexer provides 32 single channels.

Pepperl + Fuchs, Inc.    Twinsburg, OH 44087 2245
Mar 17, 2004 Model MUX2700G HART® Multiplexer connects to smart transmitters or control devices while supporting HART digital communication. Serving as gateway between workstation and field instrumentation, unit functions at RS-485 communications speed with standard operation up to 38.4 Kb/sec. Multiplexer includes single-chip microprocessor with memory for future expansion, and firmware download capability providing 20 sec download without removing unit from termination board.

Measurement Sensor offers sensing lengths to 3.3 ft.

Measurement Sensor offers sensing lengths to 3.3 ft.

LMI Technologies Inc.    Southfield, MI 48075
Mar 17, 2004 Big Beam Sensor (BBS) measures width and height of solid and opaque targets. Unaffected by target surface color or reflectivity, BBS uses modulated laser source to back light object being measured. Sensing lengths up to 3.3 ft apart can be achieved without effecting accuracy. Characteristics include 1.18 in. beam height, better than 0.5% accuracy @ 5 kHz, 30 micron repeatability, and typical resolution of 0.00012 in. of measurement range.

Shaft Horsepower Meters have analog and digital outputs.

Shaft Horsepower Meters have analog and digital outputs.

Himmelstein, S., & Co.    Hoffman Estates, IL 60195
Mar 16, 2004 Offered in accuracy grades of 0.08% and 0.13%, MCRT® Shaft Horsepower/kW-h Meters require no manual adjustments and feature bidirectional operation. Non-contact devices have full scale ranges from 5–76,000 hp, and measurements are valid to zero speed. Made with 200% and 400% torque overload ratings, they output ±10 V analogs of power, torque, speed, and energy as well as data in engineering units via resident com port.

Tension Meter ensures correct timing belt tensioning.

Tension Meter ensures correct timing belt tensioning.

BRECOflex Co., L.L.C.    Eatontown, NJ 07724
Mar 16, 2004 Model SM4 Universal Tension Meter measures frequency of all belt types, regardless of composition. It provides readings in range of 6–350 Hz ±5% and is suited for setting up belt drive systems. Meter helps eliminate belt under- and over-tensioning, reducing wear, vibration, noise, and friction.

HPLC Injectors offer multiple port and bore combinations.

HPLC Injectors offer multiple port and bore combinations.

Valco Instrument Co., Inc.    Houston, TX 77255
Mar 16, 2004 Rated for use at up to 10,000 psi liquid, Cheminert® C2XH series injectors feature 1/16 in. fittings and are available with .010 or .016 in. bore in 4, 6, and 10 port configurations, or .006 in. bore in 4 and 6 port versions. Internal volume injectors produce volumes from 10-50 or 20-100 nanoliters, depending on bore size. Versions with .004 and .006 in. bore using 1/32 in. fittings are available with pressure ratings to 20,000 psi.

Wet/Wet DP Transmitter suits HVAC applications.

Wet/Wet DP Transmitter suits HVAC applications.

Dwyer Instruments, Inc.    Michigan City, IN 46361
Mar 16, 2004 Series 629 Wet/Wet Differential Pressure Transmitter senses differential pressure of compatible gases or liquids and sends 4-20 mA output signal. Unit, designed for wetted parts of 316 and 316L stainless steel, contains pressure sensor that offers 0.5% FS accuracy on ranges from 10-100 psid. It comes in NEMA 4X housing that withstands temperatures to 200°F and is suited for monitoring differential pressures on HVAC equipment.

Digital Balance fits in shirt pocket.

Digital Balance fits in shirt pocket.

Scientifics, A Division of Edmund Scientific    Tonawanda, NY 14150-6711
Mar 16, 2004 Pocket Digital Balance indicates overload, low voltage, and stability, and freezes when stable for 2 sec. If weight is added or subtracted, balance resumes measuring. Unit automatically calibrates to 100 g, and after 1 min of non-use it automatically shuts off to preserve battery life. Protective cover folds over balance for travel and slides out of the way to reveal stainless steel platform. Balance offers range up to 200 g, resolution to 0.1 g, and accuracy to 0.1 g.

Flowmeter measures all types of conductive liquids.

Flowmeter measures all types of conductive liquids.

Siemens Energy & Automation Inc., Motors & Drives Div.    Alpharetta, GA 30005
Mar 16, 2004 Transmag 11 electromagnetic flowmeter measures sludges, pastes, and slurries. It is suitable for custody transfer measurements and for pulsating media. Measuring range covers 10ł and unit measures reliably with large variations in pressure, temperature, density, electrical conductivity, and viscosity. It can be fitted directly in base of supply lines without requiring further enclosure. Unit offers protection rated at IP68.

In-Line Checkweighers don't slow down production line.

In-Line Checkweighers don't slow down production line.

Dillon, Inc., A Div. Of Avery Weigh-Tronix    Fairmont, MN 56031-1439
Mar 16, 2004 Checkpoint models feature electromagnetic force restoration technology, offering precision to weigh, sort, or classify at throughput of 230 weighings per min. Optional rejection mechanisms automatically remove unsuitable packages from production flow. In-feed, weighing, and out-feed transport conveyors are provided. Touchscreen controls offer menu-guided operation, 80 product parameter settings, 20 automation channels, and password protection.

Diode Laser Spectrometer measures directly in hot flue gases.

Diode Laser Spectrometer measures directly in hot flue gases.

Siemens Energy & Automation Inc., Motors & Drives Div.    Alpharetta, GA 30005
Mar 16, 2004 Model LDS 6 provides continuous in-situ measurement of gas concentrations with reaction time in seconds range. It is equipped with fiber-optic sensors and maintenance-free reference cell for self-calibration. Integral communications interface permits remote scanning of measured values to set spectrometer parameters and carry out diagnostics. Unit is suited for applications involving changing gas compositions, high process temperatures, and varying concentrations of particles.

Frequency Converter offers integrated safety mechanisms.

Frequency Converter offers integrated safety mechanisms.

Siemens Energy & Automation Inc., Motors & Drives Div.    Alpharetta, GA 30005
Mar 16, 2004 Comprised of distributed intelligence, I/O, motor starter, and safety system, Model ET 200S-FC controls speed of asynchronous motors steplessly. Hot-swappable modular unit includes line-commutated regenerative feedback, closed-loop control section, and power section with rated output from 0.75–4 kW. Safe Stop function prevents unintentional starting of drive, while Safe Braking Ramp monitors standstill, and Safe Reduced Speed prevents speed limit from being exceeded.

I/O Module and Safety Monitor suit Category 4 operation.

I/O Module and Safety Monitor suit Category 4 operation.

Siemens Energy & Automation Inc., Motors & Drives Div.    Alpharetta, GA 30005
Mar 16, 2004 Flexible I/O module S22.5F and safety monitor unify safety and standard technology on AS-interface bus. S22.5F, with IP20 degree protection, has 2 inputs that enable safe link to signals in control cabinet. Safety monitor offers integrated on- and off-delays as well as pulse functions. Momentary shutdowns are saved in buffer memory, logical functions can be linked with each other and cascaded, and safety-related components can be configured virtually.

Flare Flowmeter validates calibration while installed.

Flare Flowmeter validates calibration while installed.

Fluid Components Intl.    San Marcos, CA 92069 5115
Mar 16, 2004 Model GF03 utilizes VeriCal™ in-situ calibration verification kit to meet environmental agency regulations that require installed calibration checks of flow instrumentation used in flare gas systems. It meets specifications for +5% accuracy, repeatability of +0.5% of reading and flow range from 0.50–275 sfps. Operating in temperatures from -40 to 350°F and pressures to 100 psig, sensor is effective for reading and reporting low and high flow rates.

Optical Encoders offer plug and play installation.

Optical Encoders offer plug and play installation.

BEI - Duncan Electronics    Irvine, CA 92618
Mar 16, 2004 Series 920 miniature, incremental encoders are capable of accepting disc radii as small as 9.78 mm with resolutions to 2,450 ppr. Featuring 5-pin mating connector that mates with AMPHEONOL and MOLEX configurations, units measure 1.25 x 1.05 x 0.39 in. including caliper, connector, and PCB board. Opto-ASIC design includes phased array photo diode IC noted for ±0.010 in. tolerance to axial movement and 50 mA power consumption.

Distance Measuring System has 20 cm to 170 m range.

Distance Measuring System has 20 cm to 170 m range.

Leuze electronic, Inc.    New Hudson, MI 48165
Mar 16, 2004 Model OMS 2 Laser Optical Distance Measuring System incorporates signal processors coupled with laser technology to allow values of measured distances to be calculated within milliseconds. Data communication between position controller/PLC and unit takes place via SSI, Profibus, Interbus, deviceNet, CANopener, or RS 422/485 interfaces. With IP65 protection rating, construction includes metal housing and glass optics.

Power Monitors measure multiple 3-phase parameters.

Power Monitors measure multiple 3-phase parameters.

Carlo GAVAZZI Automation Components    Buffalo Grove, IL 60089
Mar 15, 2004 Model WM12 multi-function, 3-phase power monitors are available in 96 mm˛ panel mount Ľ DIN housing with 46 mm behind panel depth, or with DIN rail mounting style for mounting within electrical enclosures. They monitor electrical parameters for 3-phase, including power factor, frequency, demand, and reactive energy. Both styles are available with communication functions that utilize Modbus®-RTU protocol for monitoring up to 255 individual instruments.

Analyzer tests all functions of external pacemakers.

Analyzer tests all functions of external pacemakers.

Netech Corp.    Hicksville, NY 11801-1502
Mar 12, 2004 Featuring menu-driven operation with 8 tactile keys and 4-line LCD display, portable EXPMT 2000 tests and verifies all functions of any external pacemaker. ECG snaps (5) are standard along with RS 232 serial port, which allows for printing heading and test measurements on separate printer. Information can also be sent to Palm Pilot. For use with transcutaneous pacers, External Test Load has 12 user-selectable loads from 100–1,000 ohms.

Analyzer tests defibrillators and pacemakers.

Analyzer tests defibrillators and pacemakers.

Netech Corp.    Hicksville, NY 11801-1502
Mar 12, 2004 Delta 3000A analyzes defibrillators with monophasic or bi-phasic waveforms and all AEDs. With 12 built-in user-selectable test loads, unit can also test transcutaneous pacemakers. ECG simulator provides 12 arrhythmias plus sine, square, and triangle performance waveforms. Operation is via menus and 8 tactile feel keys. Instructions and measurements are displayed on 4-line, LCD display, while print key ouputs test measurements to RS-232 serial port.




(Showing headlines 12461 - 12480)   << 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy