Test & Measuring Instruments
(Showing headlines 12041 - 12060) << 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 ...
|
 Digital-to-Synchro Converters drive torque receivers.Computer Conversions Corp.
East Northport, NY 11731
Jul 20, 2004 Miniature Converter Modules provide up to 3 VA power output and ±6 minute accuracy when driving size 11 TR load. Units accept 14-bit natural binary angle and convert it into 3-wire synchro or 4-wire resolver signal. Output is short-circuit protected and only ±15 V and +5 Vdc power supplies are required. Standard output voltages are 90 or 11.8 Vrms L-L, 60 or 400 Hz. Digital inputs are TTL/DTL compatible and synchro output and reference is transformer isolated. |
 RF Power Analyzer includes GSM measurement option.Keithley Instruments, Inc.
Cleveland, OH 44139 1891
Jul 20, 2004 Model 2800 comes with option for making GSM transmitter quality modulation measurements. Flexible, scalable solution measures whether mobile phone transmitter or RFIC transmitter module conforms to GSM standards for modulated transmissions. Capable of calibrating phone as well as assessing modulation quality in one unit, product is designed for measuring power in 800 and 900 MHz cellular band as well as DCS (1,700 MHz) and PCS (1,800 MHz) bands. |
Control/Interface Module offers integrated motion.Rockwell Automation
Milwaukee, WI 53204
Jul 20, 2004
ControlLogix/SERCOS 1756-L60M03SE Module combines ControlLogix 1756-L6x controller with SERCOS interface motion module, providing up to 6 axes of control. It uses RSLogix 5000 v.13 programming software with 38 motion instructions for configuration. Module supports ladder, function block, sequential function chart, and structured text programming languages. CompactFlash memory provides removable non-volatile storage for user programs, tag data, and firmware.
|
 Electronic Chamfer Gage comes with universal SPC.Barcor, Inc.
Deerfield, IL 60015
Jul 19, 2004 Series-II Electronic Chamfer Gage, powered by 2 replaceable batteries, directly reads major diameter of chamfered, countersunk, tapered, or straight through holes. Resolution of 0.0002 in. is provided, with option of selecting 0.0005 or 0.001 in. Unit is equipped with 3 types of SPC outputs: Standard RS232, Present BCD Parallel, and Pseudo RS232. Programmable features include Inch/Metric conversion, Incremental Measuring Mode, Comparative Reading Mode, and Display or Freeze Hold. |
 Flue-Gas Analyzer offers data logging and integral printer.AMETEK Solidstate Controls
Columbus, OH 43085
Jul 19, 2004
Lancom III measures COlow, CO high, O2, NO, NO2, NOx, SO2, H2S, CO2 and hydrocarbons. It calculates combustion efficiency, loss, excess air, CO2, and total NOx and provides measurement corrections such as oxygen normalization, wet or dry analysis, and automatic reading conversions. Insight software allows data capture, storage, analysis, and presentation of measurement information in Windows(TM)-based program.
|
 LCD Hour Meter/Counter handles harsh environments.Redington Counters Inc.
Windsor, CT 06095
Jul 19, 2004 Offered in 4 industry style housings, NEMA 4x Model 33 features always-on 0.28 in. display. Unit operates on 10–277 Vdc and 20–277 Vac, and ac voltage range is not frequency sensitive. Totally sealed construction protects against ingress of dirt and moisture and enables use in environments with adverse conditions. Hour-meter unit runs indicator-blinking decimal point. Clip retainer mount and screws are supplied. |
 Instrumentation System features modular design.Swagelok Company
Solon, OH 44139-3492
Jul 19, 2004 Kenmac Series 85 interface and mounting system includes 2- and 4-valve manifolds for pressure and differential pressure measurement, self-venting single and double purge blocks, electric heaters, steam trace blocks, and protective shade made from fire-retardant fiberglass with stainless steel fasteners. Monoflanges provide isolation and vent functions for instrument or indicator mounting. System features metal-to-metal seals and parallel threads in accordance with BS-2779. |
 LED Indicators allow lamp changes after installation.Lumex Inc.
Carol Stream, IL 60188
Jul 16, 2004
Series SSF-LXH4RA right-angle LED indicators mount to printed circuit board without additional spacers or mounting hardware. Construction enables any 2-leaded LED to be installed before or after sockets have been soldered to board, which also allows users to change color or brightness. Products are available in 9 standard units in red, green, yellow, bi-color red/green, and blinking red versions. Applications include status and fault indicators and backlighting.
|
 Impedance Converter Kit permits use of probe with DMM.Cal Test Electronics
Yorba Linda, CA 92887-4604
Jul 16, 2004 Model CT3197 adapts High Voltage Oscilloscope Probe Model CT2982 for use with standard digital multimeter. Kit, comprised of BNC feed-through terminator and BNC-to-4 mm banana plug adapter, features DC-to-50 MHz bandwidth, 1 W max working power, and ±0.25% accuracy. By utilizing both components of kit to connect probe and DMM, BNC feed-through terminator matches impedance for proper readings. Adapter fits 0.75 in. spacing of banana plug input. |
 Panel Meter offers compact package.Love Controls
Michigan City, IN 46361
Jul 16, 2004 Housed in 1/32 DIN package, 3½-digit LCI132 Panel Meter Indicator features IP 65/NEMA 4X front panel and can be programmed to scale that is needed. Inputs are available for 0–10 V and 4–20 mA, as well as ac volts, ac amps, dc volts, and dc amps. Optional 4/48 Vac operation is available. |
 Digital I/O Card combines optoisolation and high voltage.United Electronic Industries
Canton, MA 02021
Jul 16, 2004
PCI-bus card, Model PD2-DIO-128i supplies 64 digital inputs and 64 digital outputs, each line with its own optoisolator. I/Os are configured in fixed banks of 16 lines. Each line runs at 10 kHz max and works from external supply voltage of 12-32 V. Outputs generate 500 mA/channel peak and 200 mA/channel continuous with max of 1 A/port. Operating on 3.3 or 5 V PCI-bus backplanes, board includes 33 MHz DSP that offloads host processor of supervisory duties.
|
Cabinet delivers modular I/O expansion.IBM (Corporate Headquarters)
Armonk, NY 10504-1783
Jul 16, 2004 Rack-mountable IBM 7311 Model D11 I/O Drawer, designed to attach to IBM eServer® p5 570 system, is suited for users who need more than 24 I/O slots. Each drawer provides six 64 bit, 3.3 V, hot-plug PCI-X slots, and up to 20 units are supported by model 570 with connections via remote I/O adapters and cables. Product requires 4U of vertical space in 19 in. rack and holds one or two D10 or D11 drawers. Unit also features redundant hot-plug power and cooling. |
 Measuring Receiver System calibrates RF signal generators.Agilent Technologies, Inc.
Santa Clara, CA 95051
Jul 15, 2004
Model N5530S is based on company's PSA Series spectrum analyzers and EPM/EPM-P power meters. Standard frequency coverage of 3 GHz is provided. Measurements up to 26.5 GHz can be performed without external downconverters. Unit offers minimum RF bandwidth of 1 Hz and 160 different bandwidths. It has integrated demodulation distortion measurement capability. System has 3 sensor modules; option 504, 518 and 526; which connect device under test to spectrum analyzer and power meter.
|
 Pocket-Sized Testing Units measure pH and temperature.Cole-Parmer Instrument Co.
Vernon Hills, IL 60061
Jul 15, 2004
Oakton® pHTestrs® 10, 20, 30, and BNC feature IP67-rated housing with 1 1/16 in. tall display and, on pHTestr 30, dual pH/temperature readout. All models offer buffer recognition at USA and NIST standard buffer values and up to 3-point pH calibration. Other standard features include 3-segment battery-life indicator, Valox® electrode housing, and double-junction electrode sensors. In addition to Hold and Auto-Off functions, unit provides self-diagnostic error messages.
|
 Retail Scale/Printer helps grocers manage business.Mettler Toledo, Inc.
Columbus, OH 43240
Jul 15, 2004 Model 8442 incorporates large tower display featuring dual LCD messages. Retailer PC applications can be used to create custom label formats and to maintain all scale related data. Integrated printer offers large label capacity, slides out for access and label loading, and provides default label formats for all specified label types. |
 Portable Shock Recorder logs max shock and time it occurred.MadgeTech
Warner, NH 03278
Jul 15, 2004 Battery-powered, Tri-Axial SHOCK101 measures and records shock as peak acceleration levels over user-defined interval and can be started and stopped directly from computer. Featuring Windows®-based software that lets user collect, display, and analyze data, recorder has serial interface and is compatible with Palm Pilot®. Sampling at 500 Hz, unit stores peak value for selected interval from 8 readings/sec to 1 reading/hr and stores 43,690 readings/channel. |
 Pressure Analysis System supports up to 10,240 sensors.Pressure Profile Systems Inc.
Los Angeles, CA 90045
Jul 15, 2004 Model T3000 turnkey tactile pressure measurement system enables real-time analysis of objects in direct physical contact. Windows®-compatible software converts raw sensor data into color-coded, 3D representation of pressures on irregularly shaped objects. Scalable system delivers out-of-the-box data collection with parallel-scanning architecture and capacitive sensing technology. It supports sensors, individually or in multiple-sensor arrays, at acquisition rates to 128 kHz. |
Bridge Module adds wireless connectivity to serial devices.DPAC Technologies
Garden Grove, CA 92841
Jul 15, 2004 Airborne™ Serial Bridge Module provides RS-232 interface and specific command set for OEMs looking to add wireless 802.11 connectivity to products with built-in serial interfaces. Interface supports baud rates from 300–921.4 Kbps and is capable of both full or half duplex mode and hardware and software flow control. Built-in web server provides configuration of serial interface, baud rates, network, and wireless communications parameters using web browser. |
 Robotic Probers target semiconductor test industry.Owens Design, Inc.
Fremont, CA 94538
Jul 14, 2004
Robotic Probers provide method for validating and calibrating automatic test equipment. Robots attach directly to test head and probe specific pads on device interface board. On-board CPU commands probe tip to move along high-precision linear bearings using optically encoded stepper motors for accurate positioning.
|
 Payroll Recorder automatically calculates employee time.Acroprint Time Recorder Co.
Raleigh, NC 27616
Jul 14, 2004 Totalizing payroll recorder ES1000 calculates time between punches and totals time in hours and minutes. It can also deduct break times and is capable of generating reports such as Hours Summary Report, which provides log of hours that employees have worked. Product handles weekly, bi-weekly, semi-monthly, or monthly pay periods for up to 100 employees. It adjusts for DST and features signal control for external bells or horns. |
(Showing headlines 12041 - 12060) << 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756
|
|
|