Test & Measuring Instruments
(Showing headlines 11941 - 11960) << 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 ...
|
 Output Modules allow remote monitoring with no field wiring.Accutech Div., Adaptive Instruments Inc.
Hudson, MA 01749
Aug 09, 2004
Analog, Digital, and Analog/Digital Output Modules allow users to integrate wireless monitoring instrumentation into existing control systems. Base Radio accessories transmit analog or digital outputs from remote locations to data acquisition systems without external power or signal wire installation. Analog modules provide four 4-20 mA analog outputs, while digital modules offer 8 switch-closure outputs. Analog/digital modules provide capability of both.
|
 Temperature Sensor has built-in signal conditioning.Webster Instruments
Milwaukee, WI 53235
Aug 09, 2004 Series TP200 Temperature Sensor provides 0–5 Vdc or 4–20 mA linear analog output. Simple 2- or 3-wire hook-up eliminates problems associated with cold junction compensation, curve fitting, and typical thermocouple limitations. Measuring 3.9 in. long by 0.86 in. in diameter, with weight of only 10 oz, sensor is available with #4 SAE, NPT, or BSP ports. It offers temperature range of 0–150°C in high-pressure stainless steel capsule rated to 6900 psi. |
 Differential Pressure Instruments have piston-type sensors.Orange Research, Inc.
Milford, CT 06460
Aug 09, 2004 Series 1200 and 1300 instruments, switches, and gauge-switch combinations incorporate piston-magnet sensor that responds to changes in pressure. Fabricated from aluminum, 316 stainless steel, or naval brass, instruments are rated for 3,000–10,000 psig line pressures and offer selectable differential pressure ranges from 5–1,000 psid. Switches or gauge-switch combinations are available with multiple reed switches and Nema 4X enclosures. |
 Magnetic Bubble Level is designed for electricians.Greenlee Textron, Inc.
Rockford, IL 61109
Aug 09, 2004 With mini-torpedo design, L77 utilizes 3 rare earth magnets to maximize holding strength. No dog attachment facilitates bending offsets, while 4-vial design enables 0°, 90°, 45°, and 30° angle levels. V-groove on top of level offers straightforward view of each vial. Machined from aluminum alloy and anodized to aircraft standards, product has bending offsets and calculations permanently laser-engraved onto level. |
 Expansion Module adds discreet I/O to motion controller.Delta Computer Systems, Inc.
Vancouver, WA 98682
Aug 09, 2004 Model Exp70-D8 provides up to 32 discrete I/O, in 4 software-configurable sets of inputs and outputs, to RMC70 Series motion controllers. It has 12–24 V input range, while outputs can switch 100 mA in same voltage range. Field-changeable unit delivers mix and match flexibility for motion controllers targeted towards hydraulic, pneumatic, and electric servo motion control applications with position, speed, and position-pressure or force needs. |
 Handheld Tester checks vehicle electrical systems.Snap-on Industrial
Kenosha, WI 53141 1410
Aug 06, 2004 Used to test and troubleshoot wired components in transportation electrical systems, CT3000KT Multi-Probe is constructed with solvent-resistant, ABS plastic exterior. It tests continuity of electrical circuits and correct wiring polarity, operating on dc systems from 6–48 V. LED light and audible tone indicate positive, negative, or ground polarity, eliminating potential for incorrect connections, while recessed membrane-covered switches prevent accidental power-up. |
 Controller Module suits embedded computer systems.Parvus Corp.
Salt Lake City, UT 84115 2913
Aug 06, 2004
Fast1394(TM) 3-port IEEE-1394b controller card supports data transfer rates up to 800 Mbits/s over 3 plug-and-play, bilingual FireWire ports, galvanically-isolated between transceiver and link controller. Supporting hot pluggable connections, card provides automatic detection and configuration. It requires single 5 V power supply and is capable of supplying up to 45 W of power to external peripherals via 1394 cable. Fast1394 is fully compliant with OHCI v1.1 specification.
|
 Wireless LAN Tester fulfills high-volume production needs.LitePoint Corporation
San Jose, CA 95134-2031
Aug 05, 2004 IQflexâ„¢ 802.11a/b/g WLAN Manufacturing Test Solution offers capabilities of vector signal analyzer, vector signal generator, spectrum analyzer, and power meter. It measures error vector magnitude, spectral mask compliance, and phase noise levels. IQflex uses LitePoint Application Programming Interface to operate under control of Visual C/C++ test scripts. Test scripts can be created to support either automated pass/fail or parametric testing. |
 Single Board Computer offers 128 Mb SmartMedia storage.Saelig Co., Inc.
Pittsford, NY 14534
Aug 05, 2004
Designed for embedded datalogging applications, Model DL7000 features 16 analog inputs with individually settable input ranges, and 6 digital I/O lines. Based on Wilke Tiger modules, DL7000 can have up to 2.5 Mbytes FLASH/SRAM memory, with built-in connectors for serial I/O, external keypad, and graphic LCD. By using FLASH technology, datalogger may be updated in-field and can store data and parameter settings. Programming is via any PC in BASIC language.
|
 USB Devices allow portable data acquisition.National Instruments Corp.
Austin, TX 78759-3504
Aug 05, 2004 Offering 16-bit accuracy, DAQPad-6015 and DAQPad-6016 feature maximum sampling rate of 200 kS/sec for single channel. The 4-channel, 24-bit, USB-9211 provides thermocouple measurement, while 4-channel, 16-bit USB-9215 offers simultaneous sampling, measuring multiple signals with minimal phase delay. Both deliver integrated signal conditioning. SCXI-1600 DAQ module delivers plug-and-play USB connectivity to 40 measurement modules within NI SCXI signal conditioning platform. |
 Flue Gas Analyzers include built-in sample pump.Nova Analytical Systems Inc.
Niagara Falls, NY 14301 2398
Aug 05, 2004 Series 7200 offers continuous analysis of flue gas for any combination of O2, CO, CO2, NOx or combustibles from combustible processes burning clean fuel gas. With appropriate sample preconditioning, units can also measure sample gases from oil or coal-fired processes. Analyzers include digital readout for each gas, recorder output, automatic condensate removal, plus multiple gas and sample point capability. |
 Revenue Meters are socket- and switchboard-based.Electro Industries/Gaugetech
Westbury, NY 11590
Aug 05, 2004 Based on Nexus platforms, Models 1262/1272 revenue meters provide solutions for metering, communication, and power quality. Units record all aspects of power and transmit metering data via DNP, Modbus, telephone, and Ethernet channels. This enables transmission via open protocol to many systems, simultaneously. Products are designed for critical monitoring applications such as high voltage couplings, critical customers, and power pool metering. |
Pressure Transducer is usable in natural gas vehicles.Texas Instruments, Inc., Sensors & Controls
Attleboro, MA 02703 0964
Aug 05, 2004 Series 3PP8 silicon MEMs strain gauge sensor features self-diagnostic capabilities that interface with electronic engine control systems to aid in controlling engine performance and monitoring system status. Hermetically sealed device, packaged in stainless steel casing, resists rust and uses sensing element that ensures optimal operation in industrial media. Product features EEPROM memory, allowing storage of calibration coefficients and serialization data. |
 Fiber Optic-to-Serial Converter offers redundancy feature.Advantech Automation Corp.
Cincinnati, OH 45240
Aug 04, 2004
Model ADAM-4542+ converts single-mode fiber optic signals to RS-232/422/485 serial signals. Aimed at long-distance communication applications such as intelligent transportation systems, it offers transmissions up to 15 km and wavelengths at 1,310 nm. By providing fault detection on main connection between 2 modules, communication can be automatically and seamlessly switched to secondary connection.
|
 Data Acquisition System supports embedded CPUs.ACCES I/O Products, Inc.
San Diego, CA 92121 1506
Aug 04, 2004 Designed for PC/104 and PC/104-Plus configurations, integrated, intelligent Model IE-DAS is packaged in steel enclosure and has threaded inserts for panel, DIN rail, and rack-mount installations. It supports up to 4 PC/104 boards plus CPU, covering functions such as analog and digital I/O, serial communications, relay and TTL output, and wireless Ethernet options. Basic system consists of 300 MHz Pentium EBX CPU and various peripheral ports. |
 Waveform Generator/Analyzers facilitate digital interfacing.National Instruments Corp.
Austin, TX 78759-3504
Aug 04, 2004 Built on Synchronization and Memory Core architecture, Models PXI-6542 and PXI-6541 offer 100 and 50 MHz maximum clock rates and 32 channels with per-channel direction control. They can be software configured to interface with broad set of common logic families of 5.0, 3.3, 2.5, and 1.8 V. Engineers can synchronize multiple digital modules for high-channel-count applications or synchronize digital with analog modules for mixed-signal applications. |
Spectrophotometers measure chemical absorbance.Ocean Optics, Inc.
Dunedin, FL 34698
Aug 04, 2004 Series CHEMUSB2 consists of PC-based UV-VIS and VIS-NIR systems that include USB2000 spectrometer, light source, and 1 cm cuvette holder. Both systems have 2048-element CCD-array detector, providing full spectral analysis within 3 ms at 1.0 nm optical resolution. Variable longpass filter eliminates second- and third-order effects across systems' effective range. Equipped with operating software, each system plugs into USB port of any desktop or notebook PC. |
 Electrical Safety Tester offers 4-in-1 capability.Slaughter Company
Lake Forest, IL 60045
Aug 03, 2004 Model 4320 performs AC hipot, DC hipot, insulation resistance, and ground bond tests through one DUT connection. In AC hipot mode, unit outputs up to 5 kV at 20 mA and in DC hipot mode it will output up to 6 kV at 5 mA. Insulation resistance test mode offers test range up to 1,000 Megohms, while ground bond test mode provides up to 30 A of test current. Model 4320 includes electronic ramp and dwell, milliohm offset, and 6 memories that provide 6 steps per memory. |
 Level Gauge offers max measuring range of 131 ft.Krohne, Inc.
Peabody, MA 01960-3803
Aug 03, 2004 Utilizing 4 different screen displays, OPTIWAVE 7300 C Radar Level Meter measures distance, level, and volume of liquids, pastes, and solids. High signal dynamics allow detection of small level changes and clear location of product's true surface. Objects such as struts, inlets, and ladders have little effect on signal reduction. Once unit is fitted to tank, wired, and turned on, it runs self-diagnostic test to ensure proper operation. |
 HVAC Data Loggers suit both laboratory and fieldwork.E Instruments International LLC
Langhorne, PA 19047
Aug 03, 2004
MiniLog T and MiniLog T+RH record temperature and temperature and humidity, respectively. They feature acquisition sample interval from 1 second to 2 hours and ranges up to 185°F. Available with 8,000 or 16,000 data memory, programmable units include RS-232 interface, waterproof housing, built-in real-time clock, user-defined max and min alarms, and selectable °C/°F units. Data is retained when battery is low or removed.
|
(Showing headlines 11941 - 11960) << 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754
|
|
|